{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T06:03:17Z","timestamp":1776492197021,"version":"3.51.2"},"reference-count":42,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82271026"],"award-info":[{"award-number":["82271026"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.prosdent.2024.10.012","type":"journal-article","created":{"date-parts":[[2024,11,3]],"date-time":"2024-11-03T06:51:38Z","timestamp":1730616698000},"page":"592.e1-592.e9","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns"],"prefix":"10.1016","volume":"133","author":[{"given":"Yi","family":"Zhou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjia","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Han","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaochen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haiping","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0302-4492","authenticated-orcid":false,"given":"Fuming","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2024.10.012_bib1","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.3390\/molecules27051699","article-title":"Revolution of current dental zirconia: A comprehensive review","volume":"27","author":"Alqutaibi","year":"2022","journal-title":"Molecules"},{"key":"10.1016\/j.prosdent.2024.10.012_bib2","doi-asserted-by":"crossref","first-page":"2943","DOI":"10.3390\/ijerph20042943","article-title":"Clinical outcomes of monolithic zirconia crowns on posterior natural abutments performed by final year dental medicine students: A prospective study with a 5-year follow-up","volume":"20","author":"Barile","year":"2023","journal-title":"Int J Environ Res Public Health"},{"key":"10.1016\/j.prosdent.2024.10.012_bib3","doi-asserted-by":"crossref","first-page":"284","DOI":"10.2186\/jpr.JPR_D_20_00034","article-title":"Prospective study of monolithic zirconia crowns: Clinical behavior and survival rate at a 5-year follow-up","volume":"65","author":"Sol\u00e1-Ruiz","year":"2021","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.10.012_bib4","doi-asserted-by":"crossref","first-page":"249","DOI":"10.3390\/jcm9010249","article-title":"Periodontal behavior around teeth prepared with finishing line for restoration with fixed prostheses. A systematic review and meta-analysis","volume":"9","author":"Le\u00f3n-Mart\u00ednez","year":"2020","journal-title":"J Clin Med"},{"key":"10.1016\/j.prosdent.2024.10.012_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104271","article-title":"Fractographic analysis of 35 clinically fractured bi-layered and monolithic zirconia crowns","volume":"125","author":"Skjold","year":"2022","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib6","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1016\/j.dental.2017.06.009","article-title":"Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture","volume":"33","author":"Schriwer","year":"2017","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.10.012_bib7","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.104255","article-title":"Performance of stereolithography and milling in fabricating monolithic zirconia crowns with different finish line designs","volume":"115","author":"Li","year":"2021","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2024.10.012_bib8","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1080\/10426914.2022.2149792","article-title":"Study on milling performances of 3Y-TZP ceramics using PCD and PCBN tools","volume":"38","author":"Xu","year":"2022","journal-title":"Mater Manuf Process"},{"key":"10.1016\/j.prosdent.2024.10.012_bib9","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.jmst.2016.02.009","article-title":"Assessment of elasticity, plasticity and resistance to machining-induced damage of porous presintered zirconia using nanoindentation techniques","volume":"32","author":"Alao","year":"2016","journal-title":"J Mater Sci Technol"},{"key":"10.1016\/j.prosdent.2024.10.012_bib10","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/j.prosdent.2023.02.016","article-title":"Evaluation of fit and accuracy of single crowns fabricated from self-glazed zirconia compared with milled zirconia","volume":"131","author":"Marouki","year":"2024","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib11","doi-asserted-by":"crossref","first-page":"2889","DOI":"10.1016\/j.jeurceramsoc.2015.11.029","article-title":"Self-glazed zirconia reducing the wear to tooth enamel","volume":"36","author":"Liu","year":"2016","journal-title":"J Eur Ceram Soc"},{"key":"10.1016\/j.prosdent.2024.10.012_bib12","doi-asserted-by":"crossref","first-page":"112","DOI":"10.3390\/jcs7030112","article-title":"A systematic approach to determine the cutting parameters of AM green zirconia in finish milling","volume":"7","author":"Spitaels","year":"2023","journal-title":"J Compos Sci"},{"key":"10.1016\/j.prosdent.2024.10.012_bib13","doi-asserted-by":"crossref","first-page":"4339","DOI":"10.1016\/j.jeurceramsoc.2017.03.008","article-title":"Fractography of self-glazed zirconia with improved reliability","volume":"37","author":"Shen","year":"2017","journal-title":"J Eur Ceram Soc"},{"key":"10.1016\/j.prosdent.2024.10.012_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2022.105456","article-title":"Zirconia fixed dental prostheses fabricated by 3D gel deposition show higher fracture strength than conventionally milled counterparts","volume":"135","author":"Rabel","year":"2022","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2024.10.012_bib15","doi-asserted-by":"crossref","DOI":"10.1016\/j.prosdent.2021.09.010","article-title":"Effects of surface treatments and abutment shades on the final color of high-translucency self-glazed zirconia crowns","volume":"126","author":"Li","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib16","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1080\/17436753.2021.1953843","article-title":"Clinical application of fully digital self-glazed ultra-thin zirconia veneers","volume":"120","author":"Chen","year":"2021","journal-title":"Adv Appl Ceram"},{"key":"10.1016\/j.prosdent.2024.10.012_bib17","doi-asserted-by":"crossref","first-page":"363","DOI":"10.4012\/dmj.2021-236","article-title":"Three-dimensional fit of self-glazed zirconia monolithic crowns fabricated by wet deposition","volume":"41","author":"Li","year":"2022","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.10.012_bib18","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.prosdent.2021.11.023","article-title":"Adaptation and uniformity of monolithic zirconia crowns fabricated by additive 3-dimensional gel deposition","volume":"130","author":"Sun","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib19","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.jpor.2020.01.002","article-title":"Three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition","volume":"64","author":"Li","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2024.10.012_bib20","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.prosdent.2021.04.011","article-title":"Knife-edged crown fabricated by 3-dimensional gel deposition and soft milling","volume":"129","author":"Li","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib21","doi-asserted-by":"crossref","first-page":"2773","DOI":"10.3390\/pr11092773","article-title":"Effect of hot filament chemical vapor deposition filament distribution on coated tools performance in milling of zirconia ceramics","volume":"11","author":"Fan","year":"2023","journal-title":"Processes"},{"key":"10.1016\/j.prosdent.2024.10.012_bib22","doi-asserted-by":"crossref","first-page":"1467","DOI":"10.1177\/00220345221100409","article-title":"Exploring ductility in dental ceramics","volume":"101","author":"Alves","year":"2022","journal-title":"J Dent Res"},{"key":"10.1016\/j.prosdent.2024.10.012_bib23","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1016\/j.ceramint.2022.10.159","article-title":"A critical review on sintering and mechanical processing of 3Y-TZP ceramics","volume":"49","author":"Yin","year":"2023","journal-title":"Ceram Int"},{"key":"10.1016\/j.prosdent.2024.10.012_bib24","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/j.jmapro.2020.08.057","article-title":"Study and characterization of the ductile-brittle transition zone in sintered zirconia","volume":"58","author":"Singh","year":"2020","journal-title":"J Manuf Process"},{"key":"10.1016\/j.prosdent.2024.10.012_bib25","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/0924-0136(94)01587-Q","article-title":"Productivity, surface quality and tolerances in ultrasonic machining of ceramics","volume":"51","author":"Dam","year":"1995","journal-title":"J Mater Process Technol"},{"key":"10.1016\/j.prosdent.2024.10.012_bib26","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/jace.17502","article-title":"Micromechanics of machining and wear in hard and brittle Materials","volume":"104","author":"Lawn","year":"2021","journal-title":"J Am Ceram Soc"},{"key":"10.1016\/j.prosdent.2024.10.012_bib27","series-title":"Machinability of ceramic blanks for dental CAD\/CAM restorations","author":"Mohamed","year":"2022"},{"key":"10.1016\/j.prosdent.2024.10.012_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.prosdent.2020.01.012","article-title":"Analysis of correlation between optical and microtomography measurements of cementation space in CAD-CAM ceramic crowns","volume":"124","author":"Piras","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib29","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/j.prosdent.2021.07.024","volume":"129","author":"El-Ashkar","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib30","unstructured":"Shen J.Z., Zhao J., Inventors; Hangzhou Erran Technology Co Ltd, assignee. Dental all-ceramic restoration and manufacturing method thereof. Dec 17 2019. US patent 10507090."},{"key":"10.1016\/j.prosdent.2024.10.012_bib31","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.prosdent.2019.06.003","article-title":"Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners","volume":"124","author":"Revilla-Le\u00f3n","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib32","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103792","article-title":"Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study","volume":"113","author":"Lerner","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib33","first-page":"651","article-title":"A new triple-scan protocol for 3D fit assessment of dental restorations","volume":"42","author":"Holst","year":"2011","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2024.10.012_bib34","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.prosdent.2016.06.017","article-title":"Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol","volume":"117","author":"Dahl","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib35","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1111\/eos.12576","article-title":"Digital evaluation of marginal and internal fit of single-crown fixed dental prostheses","volume":"126","author":"Dahl","year":"2018","journal-title":"Eur J Oral Sci"},{"key":"10.1016\/j.prosdent.2024.10.012_bib36","first-page":"9","article-title":"Digital evaluation of the fit of zirconia-reinforced lithium silicate crowns with a new three-dimensional approach","volume":"49","author":"Zimmermann","year":"2018","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2024.10.012_bib37","first-page":"9","article-title":"In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions","volume":"46","author":"Ender","year":"2015","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2024.10.012_bib38","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.1016\/j.dental.2022.11.002","article-title":"3D printing and milling accuracy influence full-contour zirconia crown adaptation","volume":"38","author":"Camargo","year":"2022","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2024.10.012_bib39","doi-asserted-by":"crossref","first-page":"52","DOI":"10.4012\/dmj.2017-443","article-title":"Five-axis laser milling system that realizes more accurate zirconia CAD\/CAM crowns by direct milling from fully sintered blocks","volume":"38","author":"Ohkuma","year":"2019","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2024.10.012_bib40","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1038\/sj.bdj.4802708","article-title":"The estimation of cement film thickness by an in vivo technique","volume":"131","author":"McLean","year":"1971","journal-title":"Br Dent J"},{"key":"10.1016\/j.prosdent.2024.10.012_bib41","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.prosdent.2022.10.004","article-title":"Evaluation of zirconia crowns restoring endodontically treated posterior teeth with 2 finish line designs and 2 occlusal reduction schemes: A randomized clinical trial","volume":"132","author":"El-Ashkar","year":"2024","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2024.10.012_bib42","doi-asserted-by":"crossref","first-page":"e90","DOI":"10.1111\/jopr.13656","article-title":"A micro-computed tomography analysis of internal and marginal fits of fixed partial dentures: Effect of preparation finish line designs on monolithic zirconia and heat-pressed zirconia-reinforced lithium disilicate","volume":"32","author":"Elsherbini","year":"2023","journal-title":"J Prosthodont"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324007017?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391324007017?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,8,7]],"date-time":"2025-08-07T16:30:42Z","timestamp":1754584242000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391324007017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":42,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["S0022391324007017"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.10.012","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2024.10.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2025 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}