{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T06:47:05Z","timestamp":1793083625116,"version":"4.5.0"},"reference-count":40,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.prosdent.2025.03.015","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T16:25:03Z","timestamp":1744129503000},"page":"225.e1-225.e9","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Effect of different additive manufacturing technologies on the fracture load of 3-unit monolithic zirconia fixed partial dentures: In vitro mechanical evaluation and energy-dispersive spectroscopy analysis"],"prefix":"10.1016","volume":"134","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5323-5549","authenticated-orcid":false,"given":"Simge","family":"Dagistan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2230-2822","authenticated-orcid":false,"given":"Dilem","family":"Toksoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00d6zay","family":"\u00d6n\u00f6ral","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Almira Ada","family":"Diken Turksayar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2025.03.015_bib1","doi-asserted-by":"crossref","first-page":"19194","DOI":"10.1039\/C6DT03484E","article-title":"Zirconia based dental ceramics: Structure, mechanical properties, biocompatibility and applications","volume":"45","author":"Gautam","year":"2016","journal-title":"Dalton Trans"},{"key":"10.1016\/j.prosdent.2025.03.015_bib2","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.dental.2022.04.011","article-title":"Mechanical properties-translucency-microstructure relationships in commercial monolayer and multilayer monolithic zirconia ceramics","volume":"38","author":"Cokic","year":"2022","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib3","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.dental.2007.05.007","article-title":"State of the art of zirconia for dental applications","volume":"24","author":"Denry","year":"2008","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib4","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1016\/j.prosdent.2019.05.004","article-title":"Microstructural, physical, and optical characterization of high-translucency zirconia ceramics","volume":"123","author":"Sen","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib5","doi-asserted-by":"crossref","first-page":"122","DOI":"10.4047\/jap.2022.14.2.122","article-title":"Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: A comparative analysis between subtractive and additive manufacturing","volume":"14","author":"Kim","year":"2022","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2025.03.015_bib6","first-page":"369","article-title":"Three generations of zirconia: From veneered to monolithic. Part I","volume":"48","author":"Stawarczyk","year":"2017","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2025.03.015_bib7","doi-asserted-by":"crossref","first-page":"4726","DOI":"10.3390\/ma13214726","article-title":"Effect of yttria content on the translucency and masking ability of yttria-stabilized tetragonal zirconia polycrystal","volume":"13","author":"Cho","year":"2020","journal-title":"Materials (Basel)"},{"key":"10.1016\/j.prosdent.2025.03.015_bib8","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.dental.2010.10.024","article-title":"From porcelain-fused-to-metal to zirconia: clinical and experimental considerations","volume":"27","author":"Zarone","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib9","doi-asserted-by":"crossref","first-page":"e63","DOI":"10.1016\/j.dental.2014.11.015","article-title":"Zirconia abutments and restorations: From laboratory to clinical investigations","volume":"31","author":"Ferrari","year":"2015","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.prosdent.2023.03.011","article-title":"Fracture strength and energy-dispersive spectroscopy analysis of 3-unit fixed partial dentures fabricated from different monolithic zirconia materials","volume":"129","author":"Erdinc","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib11","doi-asserted-by":"crossref","first-page":"6125","DOI":"10.1007\/s00784-023-05229-2","article-title":"The effect of cyclic loading on the fracture resistance of 3D-printed and CAD\/CAM milled zirconia crowns-An in vitro study","volume":"27","author":"Refaie","year":"2023","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2025.03.015_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jdsr.2019.09.002","article-title":"Strength and aging resistance of monolithic zirconia: An update to current knowledge","volume":"56","author":"Kontonasaki","year":"2020","journal-title":"Jpn Dent Sci Rev"},{"key":"10.1016\/j.prosdent.2025.03.015_bib13","doi-asserted-by":"crossref","first-page":"985.e1","DOI":"10.1016\/j.prosdent.2023.04.008","article-title":"Dimensional accuracy and clinical adaptation of monolithic zirconia crowns fabricated with the nanoparticle jetting technique","volume":"132","author":"Lyu","year":"2024","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib14","doi-asserted-by":"crossref","first-page":"104","DOI":"10.3390\/dj9090104","article-title":"Additive manufacturing of zirconia ceramic and its application in clinical dentistry: A review","volume":"9","author":"Khanlar","year":"2021","journal-title":"Dent J (Basel)"},{"key":"10.1016\/j.prosdent.2025.03.015_bib15","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1186\/s12903-023-03184-8","article-title":"Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns","volume":"23","author":"Refaie","year":"2023","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2025.03.015_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105089","article-title":"Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies","volume":"147","author":"Silva","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.104942","article-title":"Assessment of the trueness of additively manufactured mol3% zirconia crowns at different printing orientations with an industrial and desktop 3D printer compared to subtractive manufacturing","volume":"144","author":"Cameron","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib18","doi-asserted-by":"crossref","first-page":"441","DOI":"10.4012\/dmj.2022-146","article-title":"Evaluation of the trueness and adaptation of zirconia crowns fabricated with stereolithography","volume":"42","author":"Li","year":"2023","journal-title":"Dent Mater J"},{"key":"10.1016\/j.prosdent.2025.03.015_bib19","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1111\/jopr.13482","article-title":"Chemical composition and flexural strength discrepancies between milled and lithography-based additively manufactured zirconia","volume":"31","author":"Revilla-Le\u00f3n","year":"2022","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.03.015_bib20","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.104255","article-title":"Performance of stereolithography and milling in fabricating monolithic zirconia crowns with different finish line designs","volume":"115","author":"Li","year":"2021","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib21","doi-asserted-by":"crossref","first-page":"176","DOI":"10.5152\/cjms.2020.1521","article-title":"Advancements in 3D printing technology: Applications and options for prosthetic dentistry","volume":"5","author":"Onoral","year":"2020","journal-title":"Cyprus J Med Sci"},{"key":"10.1016\/j.prosdent.2025.03.015_bib22","first-page":"27","article-title":"Additive manufacturing technologies for processing zirconia in dental applications","volume":"23","author":"Revilla-Leon","year":"2020","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib23","doi-asserted-by":"crossref","first-page":"1860","DOI":"10.3390\/ma16051860","article-title":"Recent advances on 3D-printed zirconia-based dental materials: A review","volume":"16","author":"Branco","year":"2023","journal-title":"Materials (Basel)"},{"key":"10.1016\/j.prosdent.2025.03.015_bib24","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.prosdent.2021.09.027","article-title":"Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks","volume":"130","author":"Attia","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib25","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1111\/ijac.13806","article-title":"Effect of binder system on the thermophysical properties of 3D-printed zirconia ceramics","volume":"19","author":"Hofer","year":"2022","journal-title":"Int J Appl Ceram Technol"},{"key":"10.1016\/j.prosdent.2025.03.015_bib26","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1007\/s43207-024-00416-7","article-title":"Advances and challenges in zirconia-based materials for dental applications","volume":"61","author":"Han","year":"2024","journal-title":"J Korean Ceram Soc"},{"key":"10.1016\/j.prosdent.2025.03.015_bib27","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/S0022-3913(12)60112-7","article-title":"Flexural strength and the probability of failure of cold isostatic pressed zirconia core ceramics","volume":"108","author":"Siarampi","year":"2012","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib28","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.compscitech.2015.06.020","article-title":"Influence of voids on the compressive failure behaviour of fibre-reinforced composites","volume":"117","author":"Liebig","year":"2015","journal-title":"Compos Sci Technol"},{"key":"10.1016\/j.prosdent.2025.03.015_bib29","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.dental.2020.01.006","article-title":"Suitability of 3D printed pieces of nanocrystalline zirconia for dental applications","volume":"36","author":"Branco","year":"2020","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib30","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1080\/17436753.2019.1709687","article-title":"Stereolithography-fabricated zirconia dental prostheses: concerns based on clinical requirements","volume":"119","author":"Li","year":"2020","journal-title":"Adv Appl Ceram"},{"key":"10.1016\/j.prosdent.2025.03.015_bib31","doi-asserted-by":"crossref","DOI":"10.1111\/jopr.13943","article-title":"Effect of artificial aging on fracture toughness and hardness of 3D-printed and milled 3Y-TZP zirconia","author":"Alhotan","year":"2024","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.03.015_bib32","first-page":"104","article-title":"Vat photopolymerization based digital light processing 3D printing hydrogels in biomedical fields: Key parameters and perspective","volume":"24","author":"Lu","year":"2024","journal-title":"Addit Manuf"},{"key":"10.1016\/j.prosdent.2025.03.015_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.prosdent.2024.01.010","article-title":"Influence of glazing and aging on the marginal, axial, axio-occlusal, and occlusal fit of 3-unit monolithic zirconia restorations fabricated using additive and subtractive techniques","volume":"131","author":"Toksoy","year":"2024","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib34","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.3390\/mi14071480","article-title":"A review of the residual stress generation in metal additive manufacturing: analysis of cause, measurement, effects, and prevention","volume":"14","author":"Bastola","year":"2023","journal-title":"Micromachines (Basel)"},{"key":"10.1016\/j.prosdent.2025.03.015_bib35","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1046\/j.1365-2842.2001.00692.x","article-title":"Quantitative study of bite force during sleep associated bruxism","volume":"28","author":"Nishigawa","year":"2001","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2025.03.015_bib36","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/S0109-5641(03)00010-1","article-title":"Weibull analysis and flexural strength of hot-pressed core and veneered ceramic structures","volume":"19","author":"Bona","year":"2003","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib37","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.prosdent.2016.09.004","article-title":"Effect of polishing procedures and hydrothermal aging on wear characteristics and phase transformation of zirconium dioxide","volume":"117","author":"Bartolo","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib38","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.dental.2019.02.017","article-title":"New multi-layered zirconias: Composition, microstructure and translucency","volume":"35","author":"Kolakarnprasert","year":"2019","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2025.03.015_bib39","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1067\/mpr.2002.123850","article-title":"Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures","volume":"87","author":"Oh","year":"2002","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.03.015_bib40","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/j.jdent.2013.10.007","article-title":"Fatigue of dental ceramics","volume":"41","author":"Zhang","year":"2013","journal-title":"J Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325002641?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325002641?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T22:35:25Z","timestamp":1762209325000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391325002641"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["S0022391325002641"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.03.015","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of different additive manufacturing technologies on the fracture load of 3-unit monolithic zirconia fixed partial dentures: In vitro mechanical evaluation and energy-dispersive spectroscopy analysis","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.03.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2025 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}