{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:30:44Z","timestamp":1788957044269,"version":"build-2803163510"},"reference-count":30,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003996","name":"Kunming Medical University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003996","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.prosdent.2025.04.024","type":"journal-article","created":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T15:19:44Z","timestamp":1747063184000},"page":"224-229","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Peri-implantitis with iatrogenic implant corrosion: A clinical report of titanium particles remaining in local tissues for up to nine years"],"prefix":"10.1016","volume":"135","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-2419-8215","authenticated-orcid":false,"given":"Yi","family":"He","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0739-1409","authenticated-orcid":false,"given":"Ding-Jie","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-1856-1391","authenticated-orcid":false,"given":"Yun-Tong","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi-Long","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ya","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Hong","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2025.04.024_bib1","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/clr.13305","article-title":"What is the impact of titanium particles and biocorrosion on implant survival and complications? A critical review","volume":"29","author":"Mombelli","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib2","article-title":"Oral microbiota in patients with peri-implant disease: A narrative review","volume":"12","author":"Butera","year":"2022","journal-title":"Appl Sci (Basel)"},{"key":"10.1016\/j.prosdent.2025.04.024_bib3","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1111\/cid.12676","article-title":"Titanium as a modifier of the peri-implant microbiome structure","volume":"20","author":"Daubert","year":"2018","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib4","doi-asserted-by":"crossref","first-page":"7383","DOI":"10.3390\/ma16237383","article-title":"Dental implants: Modern materials and methods of their surface modification","volume":"16","author":"Sotova","year":"2023","journal-title":"Materials"},{"key":"10.1016\/j.prosdent.2025.04.024_bib5","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.3390\/ijms22031067","article-title":"Titanium wear of dental implants from placement, under loading and maintenance protocols","volume":"22","author":"Romanos","year":"2021","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.prosdent.2025.04.024_bib6","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1002\/jbm.b.32735","article-title":"Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: Synergistic interactions of wear and corrosion","volume":"100B","author":"Mathew","year":"2012","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.prosdent.2025.04.024_bib7","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.jdsr.2021.09.001","article-title":"Impact of tribocorrosion and titanium particles release on dental implant complications\u2014A narrative review","volume":"57","author":"Kheder","year":"2021","journal-title":"Jpn Dent Sci Rev"},{"key":"10.1016\/j.prosdent.2025.04.024_bib8","doi-asserted-by":"crossref","first-page":"3585","DOI":"10.3390\/ijms19113585","article-title":"Potential causes of titanium particle and ion release in implant dentistry: A systematic review","volume":"19","author":"Delgado-Ruiz","year":"2018","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.prosdent.2025.04.024_bib9","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3390\/ma12030368","article-title":"A literature review study on atomic ions dissolution of titanium and its alloys in implant dentistry","volume":"12","author":"Noumbissi","year":"2019","journal-title":"Materials (Basel)"},{"key":"10.1016\/j.prosdent.2025.04.024_bib10","doi-asserted-by":"crossref","first-page":"5258","DOI":"10.3390\/ma6115258","article-title":"Titanium corrosion mechanisms in the oral environment: A retrieval study","volume":"6","author":"Rodrigues","year":"2013","journal-title":"Materials"},{"key":"10.1016\/j.prosdent.2025.04.024_bib11","doi-asserted-by":"crossref","first-page":"e562","DOI":"10.1111\/cid.12285","article-title":"In vitro investigation of the effect of oral bacteria in the surface oxidation of dental implants","volume":"17","author":"Sridhar","year":"2015","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib12","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s13167-018-0138-6","article-title":"Titanium implants and silent inflammation in jawbone\u2014A critical interplay of dissolved titanium particles and cytokines TNF-\u03b1 and RANTES\/CCL5 on overall health?","volume":"9","author":"Lechner","year":"2018","journal-title":"EPMA J"},{"key":"10.1016\/j.prosdent.2025.04.024_bib13","doi-asserted-by":"crossref","first-page":"10614","DOI":"10.3390\/ijms221910614","article-title":"Behaviour of titanium dioxide particles in artificial body fluids and human blood plasma","volume":"22","author":"Kor\u00e1bkov\u00e1","year":"2021","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.prosdent.2025.04.024_bib14","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1049\/iet-nbt.2017.0109","article-title":"Penetration, distribution and brain toxicity of titanium nanoparticles in rodents\u2019 body: A review","volume":"12","author":"Zeman","year":"2018","journal-title":"IET Nanobiotechnol"},{"key":"10.1016\/j.prosdent.2025.04.024_bib15","doi-asserted-by":"crossref","first-page":"457","DOI":"10.2106\/00004623-200004000-00002","article-title":"Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement","volume":"82","author":"Urban","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.prosdent.2025.04.024_bib16","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/01.ID.0000041425.36813.A9","article-title":"Macrophages related to dental implant failure","volume":"12","author":"Olmedo","year":"2003","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2025.04.024_bib17","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1902\/jop.2016.160524","article-title":"Increased levels of dissolved titanium are associated with peri-implantitis\u2014A cross-sectional study","volume":"88","author":"Safioti","year":"2017","journal-title":"J Periodontol"},{"key":"10.1016\/j.prosdent.2025.04.024_bib18","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1111\/clr.13372","article-title":"Dental implants-associated release of titanium particles: A systematic review","volume":"29","author":"Su\u00e1rez-L\u00f3pez Del Amo","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib19","doi-asserted-by":"crossref","first-page":"7333","DOI":"10.3390\/ijms23137333","article-title":"Effect of the size of titanium particles released from dental implants on immunological response","volume":"23","author":"Callejas","year":"2022","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.prosdent.2025.04.024_bib20","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1111\/cid.13309","article-title":"From manufacturers to clinicians, the release of dental implant particles can no longer be ignored","volume":"26","author":"Barrak","year":"2024","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib21","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/00008505-200204000-00014","article-title":"Fracture of dental implants: Literature review and report of a case","volume":"11","author":"Tagger Green","year":"2002","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2025.04.024_bib22","article-title":"Characterization of titanium corrosion and its association with peri-implantitis using energy dispersive X-ray spectroscopy: A case report","volume":"16","author":"Atchuta","year":"2024","journal-title":"Cureus"},{"key":"10.1016\/j.prosdent.2025.04.024_bib23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/jre.12479","article-title":"Can degradation products released from dental implants affect peri-implant tissues?","volume":"53","author":"Noronha Oliveira","year":"2018","journal-title":"J Periodontal Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib24","doi-asserted-by":"crossref","first-page":"392","DOI":"10.3390\/jfb14080392","article-title":"Corrosion products from metallic implants induce ros and cell death in human motoneurons in vitro","volume":"14","author":"Gla\u00df","year":"2023","journal-title":"J Funct Biomater"},{"key":"10.1016\/j.prosdent.2025.04.024_bib25","first-page":"281","article-title":"Electrochemical study on microbiology-related corrosion of metallic dental materials","volume":"13","author":"Chang","year":"2003","journal-title":"Biomed Mater Eng"},{"key":"10.1016\/j.prosdent.2025.04.024_bib26","doi-asserted-by":"crossref","first-page":"762","DOI":"10.5301\/ijao.5000154","article-title":"Implant surface factors and bacterial adhesion: A review of the literature","volume":"35","author":"Yeo","year":"2012","journal-title":"Int J Artif Organs"},{"key":"10.1016\/j.prosdent.2025.04.024_bib27","first-page":"988","article-title":"Electrochemical behaviour of microbes on orthodontic wires","volume":"89","author":"Maruthamuthu","year":"2005","journal-title":"Curr Sci"},{"key":"10.1016\/j.prosdent.2025.04.024_bib28","doi-asserted-by":"crossref","first-page":"767","DOI":"10.3390\/nano13040767","article-title":"Titanium dioxide nanoparticles modulate systemic immune response and increase levels of reduced glutathione in mice after seven-week inhalation","volume":"13","author":"Lehotska Mikusova","year":"2023","journal-title":"Nanomaterials"},{"key":"10.1016\/j.prosdent.2025.04.024_bib29","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1177\/0022034517740560","article-title":"Is metal particle release associated with peri-implant bone destruction? An emerging concept","volume":"97","author":"Fretwurst","year":"2018","journal-title":"J Dent Res"},{"key":"10.1016\/j.prosdent.2025.04.024_bib30","doi-asserted-by":"crossref","first-page":"321","DOI":"10.7150\/ntno.56401","article-title":"The unfavorable role of titanium particles released from dental implants","volume":"5","author":"Zhou","year":"2021","journal-title":"Nanotheranostics"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325003713?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325003713?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T22:49:30Z","timestamp":1778712570000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391325003713"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["S0022391325003713"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.04.024","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Peri-implantitis with iatrogenic implant corrosion: A clinical report of titanium particles remaining in local tissues for up to nine years","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.04.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}