{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T22:39:10Z","timestamp":1762209550487,"version":"build-2065373602"},"reference-count":43,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004410","name":"Scientific and Technological Research Council of Turkey","doi-asserted-by":"publisher","award":["501965"],"award-info":[{"award-number":["501965"]}],"id":[{"id":"10.13039\/501100004410","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1016\/j.prosdent.2025.04.039","type":"journal-article","created":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T23:17:13Z","timestamp":1747783033000},"page":"865.e1-865.e7","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Trueness of digital implant scans in patients with maxillary defects: An in vitro study"],"prefix":"10.1016","volume":"134","author":[{"given":"Sema","family":"Murat","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5363-5067","authenticated-orcid":false,"given":"Burcu","family":"Batak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K\u0131van\u00e7","family":"Kamburo\u011flu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4066-9609","authenticated-orcid":false,"given":"Ayhan","family":"G\u00fcrb\u00fcz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2025.04.039_bib1","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.prosdent.2015.10.015","article-title":"Fabricating a tooth- and implant-supported maxillary obturator for a patient after maxillectomy with computer-guided surgery and CAD\/CAM technology: A clinical report","volume":"115","author":"Noh","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib2","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/j.1708-8208.2009.00164.x","article-title":"Three tumor patients with total maxillectomy rehabilitated with implant-supported frameworks and maxillary obturators: A follow-up report","volume":"12","author":"\u00d6rtorp","year":"2010","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib3","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.joms.2004.01.013","article-title":"Implant-supported edentulous maxillary obturators with milled bar attachments after maxillectomy","volume":"62","author":"Fukuda","year":"2004","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2025.04.039_bib4","doi-asserted-by":"crossref","first-page":"832","DOI":"10.3390\/jpm13050832","article-title":"Accuracy of conventional and digital impressions for full-arch implant supported prostheses: An in vitro study","volume":"13","author":"Drancourt","year":"2023","journal-title":"J Pers Med"},{"key":"10.1016\/j.prosdent.2025.04.039_bib5","first-page":"151","article-title":"In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw","volume":"11","author":"Jemt","year":"1996","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2025.04.039_bib6","first-page":"620","article-title":"Prosthesis misfit and marginal bone loss in edentulous implant patients","volume":"11","author":"Jemt","year":"1996","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2025.04.039_bib7","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1111\/j.1600-0501.2011.02219.x","article-title":"Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: An optical scanning study","volume":"23","author":"Papaspyridakos","year":"2012","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib8","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1016\/j.prosdent.2014.06.020","article-title":"Finite element analysis of stability and functional stress with implant-supported maxillary obturator prostheses","volume":"112","author":"de Sousa","year":"2014","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib9","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/S0022-3913(12)60086-9","article-title":"Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses","volume":"107","author":"Miyashita","year":"2012","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib10","first-page":"335","article-title":"Fabrication of obturator prosthesis by fusing CBCT and digital impression data","volume":"21","author":"Murat","year":"2018","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib11","doi-asserted-by":"crossref","first-page":"256.e1","DOI":"10.1016\/j.prosdent.2020.09.031","article-title":"Fabrication of a 3-dimensionally printed definitive cast for an obturator prosthesis by merging intraoral scan image with cone beam computed tomography data: A clinical report","volume":"126","author":"Murat","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib12","doi-asserted-by":"crossref","first-page":"366","DOI":"10.11607\/ijp.7842","article-title":"Evaluating the feasibility and accuracy of digitizing a maxillary defect model simulating various trismus conditions","volume":"36","author":"Gao","year":"2023","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib13","doi-asserted-by":"crossref","first-page":"147","DOI":"10.11607\/ijp.5095","article-title":"Feasibility and accuracy of digitizing edentulous maxillectomy defects: A comparative study","volume":"30","author":"Elbashti","year":"2017","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib14","doi-asserted-by":"crossref","first-page":"289","DOI":"10.11607\/ijp.6077","article-title":"Precision and trueness of computerized optical impressions in maxillectomy defects: An in vitro 3D comparison","volume":"32","author":"Elbashti","year":"2019","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib15","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/s10006-020-00836-9","article-title":"The use of optical scanner for the fabrication of maxillary obturator prostheses","volume":"24","author":"Brucoli","year":"2020","journal-title":"Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2025.04.039_bib16","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.3390\/diagnostics14212368","article-title":"The accuracy of intraoral scanners in maxillary defects with different model variations","volume":"14","author":"Murat","year":"2024","journal-title":"Diagnostics"},{"key":"10.1016\/j.prosdent.2025.04.039_bib17","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/3761750","article-title":"Three-dimensional accuracy of digital impression versus conventional method: Effect of implant angulation and connection type","volume":"2018","author":"Alikhasi","year":"2018","journal-title":"Int J Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib18","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1111\/jopr.13162","article-title":"Digital versus conventional full-arch implant impressions: A prospective study on 16 edentulous maxillae","volume":"29","author":"Chochlidakis","year":"2020","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib19","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1111\/jopr.13536","article-title":"Digital vs conventional full-arch implant impressions: A retrospective analysis of 36 edentulous jaws","volume":"32","author":"Papaspyridakos","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib20","unstructured":"International Organization for Standardization. ISO 5275-1. Accuracy (Trueness and Precision) of measurement methods and results. Part 1: General principles and definitions, 2nd ed. International Organization for Standardization; 2023. https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:5725:-1:ed-2:v1:en."},{"key":"10.1016\/j.prosdent.2025.04.039_bib21","doi-asserted-by":"crossref","first-page":"594","DOI":"10.3390\/jcm11030594","article-title":"In vitro accuracy of digital and conventional impressions for full-arch implant-supported prostheses","volume":"11","author":"D'Haese","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.prosdent.2025.04.039_bib22","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/jopr.13264","article-title":"Three-dimensional accuracy of conventional versus digital complete arch \u0131mplant \u0131mpressions","volume":"30","author":"Albayrak","year":"2021","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib23","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1111\/jerd.13070","article-title":"Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis","volume":"35","author":"Ashraf","year":"2023","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib24","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0295790","article-title":"Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study","volume":"18","author":"Meneghetti","year":"2023","journal-title":"PLoS One"},{"key":"10.1016\/j.prosdent.2025.04.039_bib25","doi-asserted-by":"crossref","first-page":"398","DOI":"10.4103\/jips.jips_52_22","article-title":"Do digital impressions have a greater accuracy for full-arch implant-supported reconstructions compared to conventional impressions? An in vitro study","volume":"22","author":"Shaikh","year":"2022","journal-title":"J Indian Prosthodont Soc"},{"key":"10.1016\/j.prosdent.2025.04.039_bib26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.11607\/ijp.7824","article-title":"Trueness evaluation of latest generation of intraoral scanners on complete-arch implant impressions","volume":"36","author":"\u0130\u015fsever","year":"2023","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib27","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.prosdent.2021.01.013","article-title":"Evaluation of complete-arch implant scanning with 5 different intraoral scanners in terms of trueness and operator experience","volume":"128","author":"Revell","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib28","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jpor.2019.06.001","article-title":"Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial","volume":"64","author":"Arcuri","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib29","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1111\/clr.12567","article-title":"Digital versus conventional implant impressions for edentulous patients: Accuracy outcomes","volume":"27","author":"Papaspyridakos","year":"2016","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib30","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.11607\/jomi.9907","article-title":"Influence of the angulation and insertion depth of implants on the 3D trueness of conventional and digital impressions","volume":"37","author":"\u00d6n\u00f6ral","year":"2022","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2025.04.039_bib31","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.3390\/ijerph15081599","article-title":"Accuracy of implant casts generated with conventional and digital impressions-an in vitro study","volume":"15","author":"Ribeiro","year":"2018","journal-title":"Int J Environ Res Public Health"},{"key":"10.1016\/j.prosdent.2025.04.039_bib32","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1111\/cid.13336","article-title":"Accuracy of digital and conventional implant-level impression techniques for maxillary full-arch screw-retained prosthesis: A crossover randomized trial","volume":"26","author":"Jasim","year":"2024","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105559","article-title":"Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study","volume":"153","author":"Kernen-Gintaute","year":"2025","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib34","doi-asserted-by":"crossref","first-page":"236","DOI":"10.4047\/jap.2022.14.4.236","article-title":"Comparison of accuracy between digital and conventional implant impressions: Two and three dimensional evaluations","volume":"14","author":"Bi","year":"2022","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2025.04.039_bib35","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1016\/j.prosdent.2021.01.016","article-title":"Accuracy of impressions for multiple implants: A comparative study of digital and conventional techniques","volume":"128","author":"Lyu","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib36","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1111\/clr.13548","article-title":"Effects of different types of intraoral scanners and scanning ranges on the precision of digital implant impressions in edentulous maxilla: An in vitro study","volume":"31","author":"Miyoshi","year":"2020","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib37","doi-asserted-by":"crossref","first-page":"366","DOI":"10.11607\/jomi.6855","article-title":"Comparison of three-dimensional accuracy of digital and conventional implant impressions: Effect of interimplant distance in an edentulous arch","volume":"34","author":"Tan","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2025.04.039_bib38","doi-asserted-by":"crossref","DOI":"10.1002\/cre2.857","article-title":"Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners","volume":"10","author":"Siadat","year":"2024","journal-title":"Clin Exp Dent Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib39","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1111\/clr.12994","article-title":"Digital vs. conventional full-arch implant impressions: A comparative study","volume":"28","author":"Amin","year":"2017","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2025.04.039_bib40","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.prosdent.2018.10.018","article-title":"Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression","volume":"122","author":"Kim","year":"2019","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.04.039_bib41","doi-asserted-by":"crossref","first-page":"303","DOI":"10.32604\/cmc.2020.011943","article-title":"Confocal 3D optical intraoral scanners and comparison of image capturing accuracy","volume":"66","author":"Amornvit","year":"2021","journal-title":"Comput Mater Continua"},{"key":"10.1016\/j.prosdent.2025.04.039_bib42","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.ajodo.2020.03.022","article-title":"Effect of saliva isolation and intraoral light levels on performance of intraoral scanners","volume":"158","author":"Camc\u0131","year":"2020","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"10.1016\/j.prosdent.2025.04.039_bib43","doi-asserted-by":"crossref","first-page":"366","DOI":"10.11607\/ijp.7842","article-title":"Evaluating the feasibility and accuracy of digitizing a maxillary defect model simulating various trismus conditions","volume":"36","author":"Gao","year":"2023","journal-title":"Int J Prosthodont"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325003981?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391325003981?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T22:36:30Z","timestamp":1762209390000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391325003981"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":43,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["S0022391325003981"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.04.039","relation":{},"ISSN":["0022-3913"],"issn-type":[{"type":"print","value":"0022-3913"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Trueness of digital implant scans in patients with maxillary defects: An in vitro study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.04.039","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2025 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}