{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:54:38Z","timestamp":1789754078394,"version":"4.0.1"},"reference-count":36,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T00:00:00Z","timestamp":1766188800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.prosdent.2025.12.016","type":"journal-article","created":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T12:21:54Z","timestamp":1767788514000},"page":"136-143","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Complete arch accuracy of six intraoral scanning devices: A clinical study"],"prefix":"10.1016","volume":"136","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6010-3584","authenticated-orcid":false,"given":"Andreas","family":"Ender","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2986-5370","authenticated-orcid":false,"given":"Jenny","family":"Buhl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert","family":"Mehl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2025.12.016_bib1","first-page":"101","article-title":"Intraoral scanning systems - A current overview","volume":"18","author":"Zimmermann","year":"2015","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib2","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1097\/ID.0000000000000683","article-title":"Digital implant impression technique accuracy: A systematic review","volume":"26","author":"Alikhasi","year":"2017","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib3","first-page":"23","article-title":"3D monitoring and quality control using intraoral optical camera systems","volume":"16","author":"Mehl","year":"2013","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib4","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0263722","article-title":"Detecting and monitoring dental plaque levels with digital 2D and 3D imaging techniques","volume":"17","author":"Giese-Kraft","year":"2022","journal-title":"PLoS One"},{"key":"10.1016\/j.prosdent.2025.12.016_bib5","doi-asserted-by":"crossref","first-page":"2156","DOI":"10.3390\/s22062156","article-title":"New caries diagnostic tools in intraoral scanners: A comparative in vitro study to established methods in permanent and primary teeth","volume":"22","author":"Schlenz","year":"2022","journal-title":"Sensors (Basel)"},{"key":"10.1016\/j.prosdent.2025.12.016_bib6","first-page":"11","article-title":"Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro","volume":"22","author":"Ender","year":"2019","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib7","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.prosdent.2020.07.007","article-title":"Marginal and internal adaptation of single crowns and fixed dental prostheses by using digital and conventional workflows: A systematic review and meta-analysis","volume":"126","author":"Hasanzade","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib8","doi-asserted-by":"crossref","first-page":"e784","DOI":"10.4317\/jced.57025","article-title":"Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review","volume":"12","author":"Garc\u00eda-Gil","year":"2020","journal-title":"J Clin Exp Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib9","doi-asserted-by":"crossref","first-page":"191","DOI":"10.4047\/jap.2021.13.4.191","article-title":"Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: A pilot study","volume":"13","author":"Iturrate","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2025.12.016_bib10","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/4103232","article-title":"Computerized casts for orthodontic purpose using powder-free intraoral scanners: Accuracy, execution time, and patient feedback","volume":"2018","author":"Sfondrini","year":"2018","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.prosdent.2025.12.016_bib11","first-page":"307","article-title":"Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: An in vitro study","volume":"22","author":"Passos","year":"2019","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib12","doi-asserted-by":"crossref","first-page":"688","DOI":"10.3390\/jcm9030688","article-title":"Accuracy of digital and conventional full-arch impressions in patients: An update","volume":"9","author":"Schmidt","year":"2020","journal-title":"J Clin Med"},{"key":"10.1016\/j.prosdent.2025.12.016_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2022.104114","article-title":"Influence of definitive and interim restorative materials and surface finishing on the scanning accuracy of an intraoral scanner","volume":"120","author":"Revilla-Le\u00f3n","year":"2022","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104414","article-title":"Accuracy of four recent intraoral scanners with respect to two different ceramic surfaces","volume":"130","author":"Yatmaz","year":"2023","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib15","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104521","article-title":"Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy","volume":"134","author":"Agust\u00edn-Panadero","year":"2023","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib16","first-page":"17","article-title":"Influence of intraoral conditions on the accuracy of full-arch scans by Cerec Primescan AC: An in vitro and in vivo comparison","volume":"25","author":"Keul","year":"2022","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib17","first-page":"9","article-title":"In vivo full-arch accuracy of intraoral scanners: A narrative review","volume":"25","author":"Jennes","year":"2022","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib18","article-title":"EPA consensus project paper: Accuracy of photogrammetry devices, intraoral scanners, and conventional techniques for the full-arch implant impressions: A systematic review","author":"Rutk\u016bnas","year":"2023","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib19","doi-asserted-by":"crossref","first-page":"5625","DOI":"10.1007\/s00784-022-04607-6","article-title":"Digital versus conventional full-arch impressions in linear and 3D accuracy: A systematic review and meta-analysis of in vivo studies","volume":"26","author":"Kong","year":"2022","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2025.12.016_bib20","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/j.1532-849X.2010.00673.x","article-title":"Impression materials in fixed prosthodontics: Influence of choice on clinical procedure","volume":"20","author":"Hamalian","year":"2011","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.12.016_bib21","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.jdent.2008.03.003","article-title":"Long-term dimensional stability and reproduction of surface detail of four polyvinyl siloxane duplicating materials","volume":"36","author":"Pant","year":"2008","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib22","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.prosdent.2015.09.011","article-title":"In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions","volume":"115","author":"Ender","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib23","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.prosdent.2016.10.022","article-title":"Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance","volume":"118","author":"Atieh","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib24","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jpor.2019.05.005","article-title":"Full arch precision of six intraoral scanners in vitro","volume":"64","author":"Osnes","year":"2020","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2025.12.016_bib25","doi-asserted-by":"crossref","first-page":"95","DOI":"10.4041\/kjod.2021.51.2.95","article-title":"Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision","volume":"51","author":"Kwon","year":"2021","journal-title":"Korean J Orthod"},{"key":"10.1016\/j.prosdent.2025.12.016_bib26","doi-asserted-by":"crossref","first-page":"4300","DOI":"10.3390\/ijerph19074300","article-title":"In vivo complete-arch implant digital impressions: Comparison of the precision of three optical impression systems","volume":"19","author":"Orejas-Perez","year":"2022","journal-title":"Int J Environ Res Public Health"},{"key":"10.1016\/j.prosdent.2025.12.016_bib27","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s40510-022-00416-5","article-title":"Comparative analysis of intraoral scanners accuracy using 3D software: An in vivo study","volume":"23","author":"Pellitteri","year":"2022","journal-title":"Prog Orthod"},{"key":"10.1016\/j.prosdent.2025.12.016_bib28","doi-asserted-by":"crossref","first-page":"3723","DOI":"10.3390\/jcm11133723","article-title":"Update on the accuracy of conventional and digital full-arch impressions of partially edentulous and fully dentate jaws in young and elderly subjects: A clinical trial","volume":"11","author":"Schlenz","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.prosdent.2025.12.016_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105984","article-title":"Accuracy of current intraoral scanning systems for full-arch impressions: An in vitro study","volume":"161","author":"Buhl","year":"2025","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib30","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/0022-3913(94)90215-1","article-title":"Effects of the setting stage on the accuracy of double-mix impressions made with addition-curing silicone","volume":"72","author":"Takahashi","year":"1994","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib31","unstructured":"Dentsply S. Scanner f\u00fcr Dentallabore inEos X5 - Vorteile: Warum inEos X5? 2025. Available at: \u3008https:\/\/www.dentsplysirona.com\/de-de\/entdecken\/produktmarken-entdecken\/ineos-x5.html\u3009."},{"key":"10.1016\/j.prosdent.2025.12.016_bib32","first-page":"341","article-title":"Accuracy, trueness, and precision - A guideline for the evaluation of these basic values in digital dentistry","volume":"24","author":"Mehl","year":"2021","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.prosdent.2025.12.016_bib33","first-page":"33","article-title":"Trueness, precision and accuracy: A critical overview of the concepts as well as proposals for revision","volume":"20","author":"Prenesti","year":"2015","journal-title":"Accred\u00a0Qual\u00a0Assur"},{"key":"10.1016\/j.prosdent.2025.12.016_bib34","unstructured":"JCGM 200:2012. International vocabulary of metrology: basic and general concepts and associated terms (VIM), 3rd edition. 2012; Available at: \u3008https:\/\/www.bipm.org\/documents\/20126\/2071204\/JCGM_200_2012.pdfhttps:\/\/www.bipm.org\/documents\/20126\/2071204\/JCGM_200_2012.pdf\u3009."},{"key":"10.1016\/j.prosdent.2025.12.016_bib35","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1111\/jopr.13633","article-title":"Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study","volume":"32","author":"Osman","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2025.12.016_bib36","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105703","article-title":"Full arch accuracy of intraoral scanners with different acquisition technologies: An in vitro study","volume":"156","author":"Baresel","year":"2025","journal-title":"J Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002239132500976X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002239132500976X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T20:59:32Z","timestamp":1782507572000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002239132500976X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["S002239132500976X"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.12.016","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Complete arch accuracy of six intraoral scanning devices: A clinical study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2025.12.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 The Authors. Published by Elsevier Inc. on behalf of the Editorial Council of The Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}