{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T17:43:24Z","timestamp":1782841404688,"version":"3.54.5"},"reference-count":17,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100004829","name":"Science and Technology Department of Sichuan Province","doi-asserted-by":"publisher","award":["2025ZDZX0048"],"award-info":[{"award-number":["2025ZDZX0048"]}],"id":[{"id":"10.13039\/501100004829","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82471025"],"award-info":[{"award-number":["82471025"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.prosdent.2026.01.015","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T20:47:35Z","timestamp":1770410855000},"page":"88-92","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Additively manufactured monolithic zirconia post-and-core crowns in the management of severe pathologic anterior tooth migration: A 1-year follow-up report"],"prefix":"10.1016","volume":"136","author":[{"given":"Zhicheng","family":"Yin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusen","family":"Shui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenyang","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0355-0289","authenticated-orcid":false,"given":"Haiyang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2026.01.015_bib1","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1902\/jop.2005.76.6.859","article-title":"Pathologic tooth migration","volume":"76","author":"Brunsvold","year":"2005","journal-title":"J Periodontol"},{"key":"10.1016\/j.prosdent.2026.01.015_bib2","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1093\/ejo\/cjad003","article-title":"Malocclusions, pathologic tooth migration, and the need for orthodontic treatment in subjects with stage III-IV periodontitis. A cross-sectional study","volume":"45","author":"Zas\u010diurinskien\u0117","year":"2023","journal-title":"Eur J Orthod"},{"key":"10.1016\/j.prosdent.2026.01.015_bib3","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1111\/jerd.13275","article-title":"An interdisciplinary treatment to reshape upper anterior displaced teeth by using dynamic occlusal recording with an intraoral scanner","volume":"36","author":"Han","year":"2024","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib4","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/S0022-3913(09)60137-2","article-title":"The effect of preparation height and luting agent on the resistance form of cemented cast crowns under load fatigue","volume":"102","author":"Leong","year":"2009","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103750","article-title":"Is a fiber post better than a metal post for the restoration of endodontically treated teeth? A systematic review and meta-analysis","volume":"112","author":"Martins","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib6","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.3390\/polym13071130","article-title":"Influence of post-core and crown type on the fracture resistance of incisors submitted to quasistatic loading","volume":"13","author":"Uctasli","year":"2021","journal-title":"Polymers"},{"key":"10.1016\/j.prosdent.2026.01.015_bib7","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1186\/s12903-023-03053-4","article-title":"The effect of different ferrule heights and crown-to-root ratios on fracture resistance of endodontically-treated mandibular premolars restored with fiber post or cast metal post system: An in vitro study","volume":"23","author":"Meng","year":"2023","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2026.01.015_bib8","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1111\/jopr.13522","article-title":"The accuracy of post and core fabricated with digital technology","volume":"32","author":"Piangsuk","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.01.015_bib9","doi-asserted-by":"crossref","first-page":"646","DOI":"10.4103\/jispcd.JISPCD_333_19","article-title":"Masking a metal cast post and core using high opacity e.max ceramic coping: A case report","volume":"9","author":"Alshouibi","year":"2019","journal-title":"J Int Soc Prev Commun\u00a0Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib10","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1016\/j.prosdent.2021.07.017","article-title":"Guided removal of a fractured fiber post and immediate restoration with a digitally prefabricated titanium post-and-core and zirconia crown: A clinical report","volume":"129","author":"Liu","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib11","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/S0022-3913(10)60080-7","article-title":"Evaluation of a one-piece milled zirconia post and core with different post-and-core systems: An in vitro study","volume":"103","author":"Bittner","year":"2010","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib12","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1111\/j.1532-849X.2012.00860.x","article-title":"Three-dimensional finite element analysis of custom-made ceramic dowel made using CAD\/CAM technology","volume":"21","author":"Marghalani","year":"2012","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.01.015_bib13","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.prosdent.2017.10.004","article-title":"Fabricating a custom zirconia post-and-core without a post-and-core pattern or a scan post","volume":"120","author":"Lee","year":"2018","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2025.105706","article-title":"Comparison of marginal and internal fit of custom-made post and core restorations milled with 4-axis and 5-axis milling machines in Polyetheretherketone and composite","volume":"156","author":"Mostafa","year":"2025","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib15","doi-asserted-by":"crossref","first-page":"389","DOI":"10.3390\/jfb15120389","article-title":"Evaluation of internal fit in custom-made posts and cores fabricated with fully digital versus conventional techniques","volume":"15","author":"Jensen","year":"2024","journal-title":"J Funct Biomater"},{"key":"10.1016\/j.prosdent.2026.01.015_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104415","article-title":"Fit of anterior restorations made of 3D-printed and milled zirconia: An in-vitro study","volume":"130","author":"Rues","year":"2023","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.01.015_bib17","doi-asserted-by":"crossref","first-page":"1305.e1","DOI":"10.1016\/j.prosdent.2025.06.019","article-title":"Influence of bionic microstructures on the bond strength of additively manufactured zirconia","volume":"134","author":"Sun","year":"2025","journal-title":"J Prosthet Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326000375?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326000375?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T16:43:36Z","timestamp":1782837816000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391326000375"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["S0022391326000375"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.01.015","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Additively manufactured monolithic zirconia post-and-core crowns in the management of severe pathologic anterior tooth migration: A 1-year follow-up report","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.01.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}