{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:41:38Z","timestamp":1792428098203,"version":"4.5.0"},"reference-count":53,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.prosdent.2026.03.047","type":"journal-article","created":{"date-parts":[[2026,4,19]],"date-time":"2026-04-19T05:38:06Z","timestamp":1776577086000},"page":"e277-e286","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Stress distribution of different attachment systems in mandibular implant overdentures: A 3D finite element study"],"prefix":"10.1016","volume":"136","author":[{"given":"Ays\u0131la","family":"Tekeli \u015eim\u015fek","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehmet Ali","family":"G\u00fcng\u00f6r","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ongun","family":"\u00c7elikkol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bengisu","family":"Y\u0131ld\u0131r\u0131m","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2026.03.047_bib1","first-page":"695","article-title":"A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: Peri-implant outcome","volume":"19","author":"Naert","year":"2004","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2026.03.047_bib2","first-page":"310","article-title":"Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments","volume":"23","author":"Cune","year":"2010","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib3","doi-asserted-by":"crossref","first-page":"3248","DOI":"10.3390\/polym13193248","article-title":"Biomechanical aspects of various attachments for implant overdentures: A\u00a0review","volume":"13","author":"Mirchandani","year":"2021","journal-title":"Polymers"},{"key":"10.1016\/j.prosdent.2026.03.047_bib4","first-page":"539","article-title":"Treatment concept for mandibular overdentures supported by endosseous implants: A literature review","volume":"13","author":"Batenburg","year":"1998","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2026.03.047_bib5","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/S0901-5027(98)80032-5","article-title":"Mandibular overdentures supported by two or four endosteal implants: A prospective, comparative study","volume":"27","author":"Batenburg","year":"1998","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2026.03.047_bib6","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1111\/j.1600-0501.2004.01085.x","article-title":"Mandibular overdentures supported by two or four endosseous implants: A\u00a05-year prospective study","volume":"16","author":"Visser","year":"2005","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2026.03.047_bib7","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0901-5027(97)80864-8","article-title":"Patient satisfaction with implant-supported mandibular overdentures: A\u00a0comparison of three treatment strategies with ITI-dental implants","volume":"26","author":"Wismeijer","year":"1997","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.prosdent.2026.03.047_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.103901","article-title":"Retention and wear of resin matrix attachments for implant overdentures","volume":"110","author":"Wichmann","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2026.03.047_bib9","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1111\/joor.12651","article-title":"Splinted and unsplinted overdenture attachment systems: A systematic review and meta-analysis","volume":"45","author":"Le\u00e1o","year":"2018","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.prosdent.2026.03.047_bib10","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.prosdent.2004.09.024","article-title":"A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant\u2013tissue-supported overdenture: A clinical report","volume":"93","author":"Pasciuta","year":"2005","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib11","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/j.1532-849X.2005.04029.x","article-title":"The role of abutment-attachment selection in resolving inadequate interarch distance: A clinical report","volume":"14","author":"Alsiyabi","year":"2005","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib12","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1111\/jopr.12356","article-title":"Mandibular denture base deformation with LOCATOR and ball attachments of implant-retained overdentures","volume":"25","author":"Elsyad","year":"2016","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib13","first-page":"160","article-title":"Attachment systems for mandibular single-implant overdentures: An in vitro retention force investigation on different designs","volume":"23","author":"Alsabeeha","year":"2010","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib14","doi-asserted-by":"crossref","first-page":"116","DOI":"10.4047\/jap.2016.8.2.116","article-title":"Strains around distally inclined implants retaining mandibular overdentures with LOCATOR attachments: An in vitro study","volume":"8","author":"Elsyad","year":"2016","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib15","first-page":"442","article-title":"Marginal bone loss in ball versus LOCATOR attachments in implant-retained overdentures: Systematic review and meta-analysis","volume":"55","author":"Mahmoud","year":"2024","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2026.03.047_bib16","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.11607\/jomi.4544","article-title":"Retention and stability of implant-retained mandibular overdentures using different types of resilient attachments: An in vitro study","volume":"31","author":"Elsyad","year":"2016","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2026.03.047_bib17","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1600-0501.2010.02004.x","article-title":"Mandibular single-implant overdentures: preliminary results of a randomized controlled trial on early loading with different implant diameters and attachment systems","volume":"22","author":"Alsabeeha","year":"2011","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2026.03.047_bib18","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.prosdent.2019.03.009","article-title":"Implant overdentures retained by self-aligning stud-type attachments: A clinical report","volume":"123","author":"Srinivasan","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib19","doi-asserted-by":"crossref","first-page":"245","DOI":"10.11607\/ijp.5068","article-title":"Fabrication of a mandibular implant-supported overdenture with a new attachment system: A review of current attachment systems","volume":"30","author":"Shah","year":"2017","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib20","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1111\/jopr.13516","article-title":"Retention of different attachment systems for digitally designed mandibular implant overdenture","volume":"32","author":"Abdelaziz","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib21","doi-asserted-by":"crossref","first-page":"2426","DOI":"10.1016\/j.prosdent.2025.08.010","article-title":"Effect of different implant angulations and insertion-removal cycles on the retentive force of zirconia and coated titanium denture attachments: An in vitro study","volume":"134","author":"Tangtrongmit","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib22","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/jopr.12907","article-title":"A novel extended range attachment system to retain implant overdentures: A clinical report","volume":"28","author":"Baba","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib23","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.prosdent.2018.11.009","article-title":"Dislodgement force analysis of an overdenture attachment system","volume":"123","author":"Yilmaz","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib24","doi-asserted-by":"crossref","first-page":"487.e1","DOI":"10.1016\/j.prosdent.2022.06.014","article-title":"Brushing effect on the retentive force of retentive inserts in three denture attachments: An in vitro study","volume":"128","author":"Kamonkhantikul","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib25","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1111\/jopr.13481","article-title":"Thermal cycling effect on LOCATOR system retention and metal surface roughness","volume":"31","author":"Perlis","year":"2022","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib26","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1111\/jopr.13729","article-title":"Initial retention force of three attachment systems for implant-retained mandibular overdentures: An in vitro study","volume":"33","author":"Wakam","year":"2024","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib27","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.3390\/biomedicines11061681","article-title":"The influence of cleaning solutions on the retention of overdenture attachment systems","volume":"11","author":"Monteiro","year":"2023","journal-title":"Biomedicines"},{"key":"10.1016\/j.prosdent.2026.03.047_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2023.106269","article-title":"Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: An in vitro study","volume":"150","author":"Wakam","year":"2024","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2026.03.047_bib29","doi-asserted-by":"crossref","first-page":"112","DOI":"10.11607\/jomi.4013","article-title":"Load transfer characteristics of various designs of three-implant-retained mandibular overdentures","volume":"30","author":"Tokar","year":"2015","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2026.03.047_bib30","first-page":"585","article-title":"The effects of two attachment types on the stresses introduced to the mandibular residual ridge: A 3D finite element analysis","volume":"44","author":"Dashti","year":"2013","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2026.03.047_bib31","doi-asserted-by":"crossref","first-page":"430","DOI":"10.2186\/jpr.JPR_D_22_00108","article-title":"Stress distribution of one-piece and two-piece mini-implant overdentures with various attachment systems and diameters: A finite element analysis","volume":"67","author":"Trang","year":"2022","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2026.03.047_bib32","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/0003-9969(93)90185-O","article-title":"A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible","volume":"38","author":"Meijer","year":"1993","journal-title":"Arch Oral Biol"},{"key":"10.1016\/j.prosdent.2026.03.047_bib33","first-page":"61","article-title":"Stress analysis of mandibular implant-retained overdenture with independent attachment system: Effect of restoration space and attachment height","volume":"63","author":"Ebadian","year":"2015","journal-title":"Gen Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib34","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2021.104653","article-title":"Effect of specific retention biomaterials for ball attachment on the biomechanical response of single implant-supported overdenture: A finite element analysis","volume":"122","author":"Gibreel","year":"2021","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2026.03.047_bib35","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.sdentj.2015.03.001","article-title":"A finite element study on stress distribution of two different attachment designs under implant-supported overdenture","volume":"27","author":"El-Anwar","year":"2015","journal-title":"Saudi Dent J"},{"key":"10.1016\/j.prosdent.2026.03.047_bib36","doi-asserted-by":"crossref","first-page":"e50","DOI":"10.1563\/AAID-JOI-D-13-00239","article-title":"Effect of implant height differences on different attachment types and peri-implant bone in mandibular two-implant overdentures: 3D finite element study","volume":"41","author":"Ozan","year":"2015","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.prosdent.2026.03.047_bib37","doi-asserted-by":"crossref","first-page":"e795","DOI":"10.1111\/jopr.12966","article-title":"A comparative evaluation of stress distribution with two attachment systems of varying heights in a mandibular implant-supported overdenture: A three-dimensional finite element analysis","volume":"28","author":"Khurana","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib38","first-page":"73","article-title":"LOCATOR attachment versus ball attachment: 3-dimensional finite element study","volume":"57","author":"Eltaftazani","year":"2011","journal-title":"Egypt Dent J"},{"key":"10.1016\/j.prosdent.2026.03.047_bib39","first-page":"00065","article-title":"Three-dimensional finite element analysis to evaluate stress distribution around implant-retained mandibular overdenture using two different attachment systems","volume":"2","author":"Abdelhamid","year":"2015","journal-title":"J Dent Health Oral Disord Ther"},{"key":"10.1016\/j.prosdent.2026.03.047_bib40","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/943839","article-title":"FEM analysis of mandibular prosthetic overdenture supported by dental implants: Evaluation of different retention methods","volume":"2015","author":"Cicci\u00d9","year":"2015","journal-title":"Comput Math Methods Med"},{"key":"10.1016\/j.prosdent.2026.03.047_bib41","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1563\/aaid-joi-D-19-00076","article-title":"Evaluation of stress distribution on mandibular implant-supported overdentures with different bone heights and attachment types: A 3D finite element analysis","volume":"45","author":"Unsal","year":"2019","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.prosdent.2026.03.047_bib42","doi-asserted-by":"crossref","first-page":"250","DOI":"10.4103\/0972-4052.165324","article-title":"Stress distribution patterns of implant-supported overdentures: Analog versus finite element analysis \u2013 A comparative in vitro study","volume":"15","author":"Satpathy","year":"2015","journal-title":"J Indian Prosthodont Soc"},{"key":"10.1016\/j.prosdent.2026.03.047_bib43","doi-asserted-by":"crossref","first-page":"143","DOI":"10.4047\/jap.2017.9.3.143","article-title":"Stress analysis of mandibular implant overdenture with LOCATOR and bar\/clip attachment: Comparative study with differences in the denture base length","volume":"9","author":"Yoo","year":"2017","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.03.047_bib44","doi-asserted-by":"crossref","first-page":"181","DOI":"10.15386\/mpr-1312","article-title":"Comparison of stress induced in mandible around an implant-supported overdenture with LOCATOR attachment and telescopic crowns \u2013 A finite element analysis","volume":"93","author":"Abbasi","year":"2020","journal-title":"Med Pharm Rep"},{"key":"10.1016\/j.prosdent.2026.03.047_bib45","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.prosdent.2007.02.006","article-title":"Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures","volume":"97","author":"Celik","year":"2007","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib46","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.prosdent.2003.11.007","article-title":"O-ring attachments for transitional implant-retained overdentures","volume":"91","author":"Ohkubo","year":"2004","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib47","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1067\/mpr.2003.6","article-title":"Special technique for attachment incorporation with an implant overdenture","volume":"89","author":"Sadig","year":"2003","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.03.047_bib48","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/j.1741-2358.2002.00003.x","article-title":"The McGill consensus statement on overdentures: Mandibular two-implant overdentures as first choice standard of care for edentulous patients","volume":"19","author":"Feine","year":"2002","journal-title":"Gerodontology"},{"key":"10.1016\/j.prosdent.2026.03.047_bib49","first-page":"603","article-title":"Anterior implant-supported overdentures","volume":"27","author":"Ben-Ur","year":"1996","journal-title":"Quintessence Int"},{"key":"10.1016\/j.prosdent.2026.03.047_bib50","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1563\/1548-1336(2002)028<0019:ORICES>2.3.CO;2","article-title":"Osseous regeneration in compromised extraction sites: A ten-year case study","volume":"28","author":"Hoexter","year":"2002","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.prosdent.2026.03.047_bib51","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1034\/j.1600-0501.2000.011S1108.x","article-title":"Management of the edentulous patient","volume":"11","author":"Mericske-Stern","year":"2000","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2026.03.047_bib52","doi-asserted-by":"crossref","first-page":"244","DOI":"10.3889\/oamjms.2017.047","article-title":"Influence of number of implants and attachment type on stress distribution in mandibular implant-retained overdentures: Finite element analysis","volume":"5","author":"El-Anwar","year":"2017","journal-title":"Open Access Maced J Med Sci"},{"key":"10.1016\/j.prosdent.2026.03.047_bib53","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/S0022-3913(98)70032-0","article-title":"Photoelastic stress patterns produced by implant-retained overdentures","volume":"80","author":"Kenney","year":"1998","journal-title":"J Prosthet Dent"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326002404?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326002404?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:09:04Z","timestamp":1792426144000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391326002404"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":53,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["S0022391326002404"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.03.047","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Stress distribution of different attachment systems in mandibular implant overdentures: A 3D finite element study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.03.047","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}