{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:42:34Z","timestamp":1792428154854,"version":"4.5.0"},"reference-count":34,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100005669","name":"Funda\u00e7\u00e3o de Apoio \u00e0 Pesquisa do Estado da Para\u00edba","doi-asserted-by":"publisher","award":["Finance code 486\/2025"],"award-info":[{"award-number":["Finance code 486\/2025"]}],"id":[{"id":"10.13039\/501100005669","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.prosdent.2026.05.013","type":"journal-article","created":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T19:46:14Z","timestamp":1780170374000},"page":"e268-e276","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy evaluation of dual-function scan body for recording complete arch implant-supported prostheses"],"prefix":"10.1016","volume":"136","author":[{"given":"Matheus Harllen Gon\u00e7alves","family":"Ver\u00edssimo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0597-8329","authenticated-orcid":false,"given":"Rodrigo Falc\u00e3o Carvalho Porto","family":"de Freitas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9 Luiz Miranda","family":"dos Santos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme Silva Pires","family":"de S\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luana B\u00e1rbara Rodrigues","family":"de Fran\u00e7a","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1593-0174","authenticated-orcid":false,"given":"Andr\u00e9 Ulisses Dantas","family":"Batista","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4126-7900","authenticated-orcid":false,"given":"Ana Larisse Carneiro","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2026.05.013_bib1","doi-asserted-by":"crossref","first-page":"761.e1","DOI":"10.1016\/j.prosdent.2020.07.018","article-title":"Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis","volume":"124","author":"Zarone","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib2","first-page":"265","article-title":"Accuracy of intraoral scanning of edentulous jaws with and without resin markers","volume":"23","author":"Tao","year":"2020","journal-title":"Chin J Dent Res"},{"key":"10.1016\/j.prosdent.2026.05.013_bib3","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.prosdent.2019.06.014","article-title":"Digital scanning for complete-arch implant-supported restorations: A systematic review","volume":"124","author":"Wulfman","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib4","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/ID.0000000000000283","article-title":"Accuracy of a digital impression system based on active triangulation technology with blue light for implants: Effect of clinically relevant parameters","volume":"24","author":"Gim\u00e9nez","year":"2015","journal-title":"Implant Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib5","doi-asserted-by":"crossref","first-page":"853","DOI":"10.11607\/jomi.3343","article-title":"Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth","volume":"29","author":"Gim\u00e9nez","year":"2014","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.prosdent.2026.05.013_bib6","doi-asserted-by":"crossref","first-page":"e54","DOI":"10.1111\/cid.12124","article-title":"Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience, implant angulation, and depth","volume":"17","author":"Gim\u00e9nez","year":"2015","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2026.05.013_bib7","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/3761750","article-title":"Three-dimensional accuracy of digital impression versus conventional method: Effect of implant angulation and connection type","volume":"2018","author":"Alikhasi","year":"2018","journal-title":"Int J Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib8","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.prosdent.2021.09.001","article-title":"Factors that influence the accuracy of intraoral scanning of total edentulous arches rehabilitated with multiple implants: A systematic review","volume":"129","author":"Pereira","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib9","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.prosdent.2023.07.039","article-title":"Device trueness in passivity and misfit of CAD-CAM frameworks: Conventional versus printed casts","volume":"133","author":"Pereira","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib10","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s40729-024-00543-0","article-title":"A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies","volume":"10","author":"Gehrke","year":"2024","journal-title":"Int J Implant Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib11","doi-asserted-by":"crossref","first-page":"S150","DOI":"10.1111\/jopr.13749","article-title":"Intraoral digital implant scans: Parameters to improve accuracy","volume":"32","author":"Revilla-Le\u00f3n","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib12","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.prosdent.2018.10.018","article-title":"Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression","volume":"122","author":"Kim","year":"2019","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib13","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.prosdent.2021.02.039","article-title":"Trueness of a device for intraoral scanning to capture the angle and distance between implants in edentulous mandibular arches","volume":"128","author":"Pereira","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib14","doi-asserted-by":"crossref","DOI":"10.1111\/cid.13419","article-title":"Accuracy of photogrammetry, intraoral scanning, and conventional impression for multiple implants: An in vitro study","volume":"27","author":"Lyu","year":"2025","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2026.05.013_bib15","doi-asserted-by":"crossref","first-page":"521.e1","DOI":"10.1016\/j.prosdent.2022.07.002","article-title":"Effects of long-term cinnamaldehyde immersion on the surface roughness and color of heat-polymerized denture base resin","volume":"128","author":"Mac\u00eado","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib16","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1186\/s13104-020-05353-2","article-title":"Solid index versus intraoral scanners in the full-arch implant impression: In vitro trueness evaluation","volume":"13","author":"Mangano","year":"2020","journal-title":"BMC Res Notes"},{"key":"10.1016\/j.prosdent.2026.05.013_bib17","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/0022-3913(52)90088-7","article-title":"Acrylic restorations by the operative nonpressure procedure","volume":"2","author":"Nealon","year":"1952","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib18","first-page":"e1","article-title":"The reverse scan body protocol: Completing the digital workflow","volume":"44","author":"Bedrossian","year":"2023","journal-title":"Compend Contin Educ Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib19","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1111\/jopr.13664","article-title":"Reverse scan body: A complete digital workflow for prosthesis prototype fabrication","volume":"32","author":"Papaspyridakos","year":"2023","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib20","first-page":"1","article-title":"Reverse scan body: Complete digital workflow for double full-arch zirconia prostheses","author":"Papaspyridakos","year":"2024","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib21","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.prosdent.2023.09.020","article-title":"Fabrication of a reverse-engineered custom scan body as a digital solution for recording implant position: a dental technique","volume":"134","author":"Abdelaziz","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib22","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1563\/aaid-joi-D-24-00083","article-title":"Full-arch implant-supported rehabilitation using reverse scan technique: a case report","volume":"51","author":"Nguyen","year":"2025","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.prosdent.2026.05.013_bib23","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.prosdent.2023.10.019","article-title":"A modified reverse impression technique for capturing and transferring soft-tissue information","volume":"134","author":"Rosmaninho","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib24","doi-asserted-by":"crossref","first-page":"2515","DOI":"10.1016\/j.prosdent.2024.08.012","article-title":"Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique","volume":"134","author":"Hyspler","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib25","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.prosdent.2023.06.008","article-title":"Reverse scan technique: A verification method for the implant position in intraoral scans","volume":"133","author":"Hyspler","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib26","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s40729-024-00543-0","article-title":"A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies","volume":"10","author":"Gehrke","year":"2024","journal-title":"Int J Implant Dent"},{"key":"10.1016\/j.prosdent.2026.05.013_bib27","first-page":"28","article-title":"Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision","volume":"57","author":"Ender","year":"2013","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2026.05.013_bib28","doi-asserted-by":"crossref","first-page":"212","DOI":"10.4047\/jap.2022.14.4.212","article-title":"Conventional and digital impressions for complete-arch implant-supported fixed prostheses: Time, implant quantity effect and patient satisfaction","volume":"14","author":"Pereira","year":"2022","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib29","first-page":"104","article-title":"Update on the accuracy of digital implant impressions: A coordinate-based analysis","volume":"38","author":"Schmidt","year":"2025","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib30","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1111\/jopr.13162","article-title":"Digital versus conventional full-arch implant impressions: A prospective study on 16 edentulous maxillae","volume":"29","author":"Chochlidakis","year":"2020","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib31","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1007\/s00784-012-0795-0","article-title":"Accuracy of digital models obtained by direct and indirect data capturing","volume":"17","author":"G\u00fcth","year":"2013","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2026.05.013_bib32","first-page":"1","article-title":"Evaluation of the accuracy of digital workflow for implant-supported full-arch fixed dental prostheses using a novel micro-CT measurement technique","author":"Fouda","year":"2025","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib33","doi-asserted-by":"crossref","first-page":"115","DOI":"10.4047\/jap.2025.17.3.115","article-title":"Digital versus conventional surveying for partially edentulous arches: An evaluation of accuracy and time efficiency","volume":"17","author":"Curinga","year":"2025","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.05.013_bib34","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326003422?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326003422?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:13:37Z","timestamp":1792426417000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391326003422"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["S0022391326003422"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.05.013","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy evaluation of dual-function scan body for recording complete arch implant-supported prostheses","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.05.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}