{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T12:55:22Z","timestamp":1791636922627,"version":"4.3.4"},"reference-count":31,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003052","name":"Korea Ministry of Trade Industry and Energy","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003052","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.prosdent.2026.06.028","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T22:10:14Z","timestamp":1784067014000},"page":"1097-1104","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of build orientation on marginal and internal discrepancies of zirconia crowns fabricated by using digital light processing 3D printing: A clinical study"],"prefix":"10.1016","volume":"136","author":[{"given":"Ji-Min","family":"Cha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KeunBaDa","family":"Son","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoon-Jeong","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyu Ri","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6714-8315","authenticated-orcid":false,"given":"So-Yeun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyu-Bok","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2026.06.028_bib1","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jdent.2018.10.012","article-title":"Zirconia single crowns and multiple-unit FDPs\u2014An up to 8-year retrospective clinical study","volume":"79","author":"Tanner","year":"2018","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.104925","article-title":"3D-printed versus conventionally milled zirconia for dental clinical applications: Trueness, precision, accuracy, biological and esthetic aspects","volume":"144","author":"Alghauli","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib3","doi-asserted-by":"crossref","first-page":"777","DOI":"10.11607\/ijp.6749","article-title":"Ceramic printing\u2014Comparative study of the flexural strength of 3D-printed and milled zirconia","volume":"35","author":"Bergler","year":"2022","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.06.028_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105359","article-title":"Zirconia crowns manufactured using digital light processing: Effects of build angle and layer thickness on the accuracy","volume":"151","author":"Mou","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib5","doi-asserted-by":"crossref","first-page":"6125","DOI":"10.1007\/s00784-023-05229-2","article-title":"The effect of cyclic loading on the fracture resistance of 3D-printed and CAD\/CAM milled zirconia crowns\u2014An in vitro study","volume":"27","author":"Refaie","year":"2023","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.prosdent.2026.06.028_bib6","doi-asserted-by":"crossref","first-page":"394","DOI":"10.3390\/biomimetics8050394","article-title":"Clinical effectiveness of 3D-milled and 3D-printed zirconia prosthesis: A systematic review and meta-analysis","volume":"8","author":"Dewan","year":"2023","journal-title":"Biomimetics"},{"key":"10.1016\/j.prosdent.2026.06.028_bib7","doi-asserted-by":"crossref","first-page":"613.e1","DOI":"10.1016\/j.prosdent.2023.07.025","article-title":"Effect of build angle on the dimensional accuracy of monolithic zirconia crowns fabricated with the nanoparticle jetting technique","volume":"130","author":"Lyu","year":"2023","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2023.104435","article-title":"Effect of build orientation and layer thickness on manufacturing accuracy, printing time, and material consumption of 3D printed complete denture bases","volume":"130","author":"Song","year":"2023","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib9","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1186\/s12903-024-03851-4","article-title":"Build angle effect on 3D-printed dental crowns marginal fit using digital light-processing and stereo-lithography technology: An in vitro study","volume":"24","author":"Farag","year":"2024","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2026.06.028_bib10","doi-asserted-by":"crossref","first-page":"181","DOI":"10.2186\/jpr.JPR_D_24_00092","article-title":"Influence of 3D printing orientations on physico-mechanical properties and accuracy of additively manufactured dental ceramics","volume":"69","author":"Alghauli","year":"2025","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.prosdent.2026.06.028_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103630","article-title":"3D printing parameters, supporting structures, slicing, and post-processing procedures of vat-polymerization additive manufacturing technologies: A narrative review","volume":"109","author":"Piedra-Casc\u00f3n","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib12","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.prosdent.2016.01.018","article-title":"Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression","volume":"116","author":"Su","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib13","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.prosdent.2018.10.023","article-title":"Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans","volume":"123","author":"Arezoobakhsh","year":"2020","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib14","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1038\/sj.bdj.4802708","article-title":"The estimation of cement film thickness by an in vivo technique","volume":"131","author":"McLean","year":"1971","journal-title":"Br Dent J"},{"key":"10.1016\/j.prosdent.2026.06.028_bib15","doi-asserted-by":"crossref","first-page":"182","DOI":"10.11607\/ijp.5117","article-title":"Build angle: Does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?","volume":"30","author":"Osman","year":"2017","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.06.028_bib16","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.prosdent.2020.04.028","article-title":"Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing","volume":"126","author":"Yu","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib17","doi-asserted-by":"crossref","first-page":"265","DOI":"10.4047\/jap.2017.9.4.265","article-title":"Evaluation of internal fit of interim crown fabricated with CAD\/CAM milling and 3D printing system","volume":"9","author":"Lee","year":"2017","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.06.028_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.104834","article-title":"Accuracy of zirconia crown manufactured using stereolithography and digital light processing","volume":"141","author":"Lee","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib19","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1186\/s12903-023-03184-8","article-title":"Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns","volume":"23","author":"Refaie","year":"2023","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2026.06.028_bib20","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.105151","article-title":"Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns","volume":"148","author":"Refaie","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103792","article-title":"Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study","volume":"113","author":"Lerner","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib22","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1186\/s13036-023-00396-y","article-title":"3D printed zirconia used as dental materials: A critical review","volume":"17","author":"Su","year":"2023","journal-title":"J Biol Eng"},{"key":"10.1016\/j.prosdent.2026.06.028_bib23","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1016\/j.jeurceramsoc.2019.10.058","article-title":"Flexural strength and Weibull analysis of Y-TZP fabricated by stereolithographic additive manufacturing and subtractive manufacturing","volume":"40","author":"Lu","year":"2020","journal-title":"J Eur Ceram Soc"},{"key":"10.1016\/j.prosdent.2026.06.028_bib24","doi-asserted-by":"crossref","first-page":"181","DOI":"10.3390\/dj10100181","article-title":"Comparison in terms of accuracy between DLP and LCD printing technology for dental model printing","volume":"10","author":"Tsolakis","year":"2022","journal-title":"Dent J"},{"key":"10.1016\/j.prosdent.2026.06.028_bib25","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.3390\/ma17061380","article-title":"3D printed materials for permanent restorations in indirect restorative and prosthetic dentistry: A critical review of the literature","volume":"17","author":"Balestra","year":"2024","journal-title":"Materials"},{"key":"10.1016\/j.prosdent.2026.06.028_bib26","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1016\/j.prosdent.2023.07.004","article-title":"Accuracy and margin quality of advanced 3D printed monolithic zirconia crowns","volume":"133","author":"Zhu","year":"2025","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib27","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.prosdent.2018.04.012","article-title":"Trueness analysis of zirconia crowns fabricated with 3-dimensional printing","volume":"121","author":"Wang","year":"2019","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.06.028_bib28","doi-asserted-by":"crossref","first-page":"159","DOI":"10.4047\/jap.2017.9.3.159","article-title":"Evaluation of the marginal and internal gaps of three different dental prostheses: Comparison of the silicone replica technique and three-dimensional superimposition analysis","volume":"9","author":"Park","year":"2017","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.06.028_bib29","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1186\/s12903-025-07491-0","article-title":"Marginal and internal fit accuracy of single-crown restorations: The impact of digital and conventional impression techniques","volume":"26","author":"Topdagi","year":"2026","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2026.06.028_bib30","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.dental.2023.11.007","article-title":"Effect of printing layer orientation and polishing on the fatigue strength of 3D-printed dental zirconia","volume":"40","author":"Lu","year":"2024","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2026.06.028_bib31","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/s00784-024-05533-5","article-title":"Biaxial flexural strength of 3D-printed 3Y-TZP zirconia using a novel ceramic printer","volume":"28","author":"Zenth\u00f6fer","year":"2024","journal-title":"Clin Oral Investig"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002239132600466X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002239132600466X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T12:39:33Z","timestamp":1791635973000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002239132600466X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["S002239132600466X"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.06.028","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of build orientation on marginal and internal discrepancies of zirconia crowns fabricated by using digital light processing 3D printing: A clinical study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.06.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 by the Editorial Council of The Journal of Prosthetic Dentistry. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}