{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:53:17Z","timestamp":1791582797682,"version":"4.3.4"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:00:00Z","timestamp":1789948800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","prosdent.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Prosthetic Dentistry"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.prosdent.2026.09.010","type":"journal-article","created":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:10:18Z","timestamp":1791580218000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of connector dimensions and span length on fracture resistance of high-translucency 4Y-TZP: An in vitro and finite element study"],"prefix":"10.1016","author":[{"given":"Anna Thereza Peroba Rezende","family":"Ramos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Austin","family":"Heath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8604-3073","authenticated-orcid":false,"given":"Daler Elisa","family":"Tarrazzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateus Garcia","family":"Rocha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5766-6039","authenticated-orcid":false,"given":"Rafael Rocha","family":"Pacheco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prosdent.2026.09.010_bib1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.4103\/ccd.ccd_738_18","article-title":"Full mouth rehabilitation by implant supported fixed prosthesis","volume":"11","author":"Bhandari","year":"2020","journal-title":"Contemp Clin Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib2","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/j.1708-8208.2003.tb00010.x","article-title":"\"All-on-Four\" immediate-function concept with Br\u00e5nemark System implants for completely edentulous mandibles: A retrospective clinical study","volume":"5","author":"Mal\u00f3","year":"2003","journal-title":"Clin Implant Dent Relat Res"},{"key":"10.1016\/j.prosdent.2026.09.010_bib3","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/j.prosdent.2015.08.025","article-title":"Complete-arch implant-supported monolithic zirconia fixed dental prostheses: A systematic review","volume":"115","author":"Abdulmajeed","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib4","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/clr.13277","article-title":"A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses","volume":"29","author":"Sailer","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.prosdent.2026.09.010_bib5","first-page":"875","article-title":"Implant-supported restorations in the anterior region: Prosthetic considerations","volume":"8","author":"Belser","year":"1996","journal-title":"Pract Periodontics Aesthet Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib6","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.prosdent.2015.06.022","article-title":"Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses","volume":"115","author":"Hamza","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib7","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1186\/s12903-025-06743-3","article-title":"Effect of connector size and configuration on the fracture resistance of a long-span implant-supported monolithic zirconia fixed partial denture (An in vitro Study)","volume":"25","author":"Khorshed","year":"2025","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.prosdent.2026.09.010_bib8","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/j.prosdent.2016.01.033","article-title":"Fracture rate of monolithic zirconia restorations up to 5 years: A dental laboratory survey","volume":"116","author":"Sulaiman","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib9","doi-asserted-by":"crossref","DOI":"10.7717\/peerj.15669","article-title":"Current classification of zirconia in dentistry: An updated review","volume":"11","author":"Kongkiatkamon","year":"2023","journal-title":"PeerJ"},{"key":"10.1016\/j.prosdent.2026.09.010_bib10","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1177\/0022034517737483","article-title":"Novel zirconia materials in dentistry","volume":"97","author":"Zhang","year":"2018","journal-title":"J Dent Res"},{"key":"10.1016\/j.prosdent.2026.09.010_bib11","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.dental.2018.03.006","article-title":"Aging resistance, mechanical properties and translucency of different yttria-stabilized zirconia ceramics for monolithic dental crown applications","volume":"34","author":"Camposilvan","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib12","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.jmbbm.2018.05.029","article-title":"Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations","volume":"85","author":"Pereira","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib13","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1016\/j.actbio.2008.11.015","article-title":"Finite element analysis of a four-unit all-ceramic fixed partial denture","volume":"5","author":"Dittmer","year":"2009","journal-title":"Acta BioMater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib14","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1016\/j.prosdent.2022.10.008","article-title":"Influence of connector cross-sectional geometry on the load-bearing capacity under fatigue of implant-supported zirconia fixed partial prosthesis","volume":"128","author":"Luft","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.prosdent.2026.09.010_bib15","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1111\/jopr.13487","article-title":"Fatigue resistance of 3-unit CAD-CAM ceramic fixed partial dentures: An FEA study","volume":"31","author":"Bataineh","year":"2022","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.09.010_bib16","doi-asserted-by":"crossref","first-page":"2523","DOI":"10.6026\/973206300212523","article-title":"Effect of span length and connector size on fracture resistance of monolithic zirconia FPDs: A finite element analysis","volume":"21","author":"Lakhe","year":"2025","journal-title":"Bioinformation"},{"key":"10.1016\/j.prosdent.2026.09.010_bib17","doi-asserted-by":"crossref","first-page":"65","DOI":"10.2209\/tdcpublication.2015-0034","article-title":"Effect of connector design on fracture resistance in zirconia-based fixed partial dentures for upper anterior region","volume":"57","author":"Ogino","year":"2016","journal-title":"Bull Tokyo Dent Coll"},{"key":"10.1016\/j.prosdent.2026.09.010_bib18","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/jopr.13002","article-title":"Load-bearing capacity of monolithic zirconia fixed dental prostheses fabricated with different connector designs and embrasure shaping methods","volume":"28","author":"Bakitian","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.09.010_bib19","doi-asserted-by":"crossref","first-page":"218","DOI":"10.34172\/joddd.2020.039","article-title":"Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis","volume":"14","author":"Hafezeqoran","year":"2020","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"10.1016\/j.prosdent.2026.09.010_bib20","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1111\/j.1532-849X.2012.00835.x","article-title":"Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses","volume":"21","author":"Drago","year":"2012","journal-title":"J Prosthodont"},{"key":"10.1016\/j.prosdent.2026.09.010_bib21","series-title":"ISO 14704:2016. Fine ceramics (advanced ceramics, advanced technical ceramics) - Test method for flexural strength of monolithic ceramics at room temperature","author":"International Organization for Standardization","year":"2016"},{"key":"10.1016\/j.prosdent.2026.09.010_bib22","series-title":"Mechanics of Materials","article-title":"Deflection of beams","author":"Goodno","year":"2018"},{"key":"10.1016\/j.prosdent.2026.09.010_bib23","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2023.111751","article-title":"Load bearing capability of three-units 4Y-TZP monolithic fixed dental prostheses: An innovative model for reliable testing","volume":"227","author":"Chiari","year":"2023","journal-title":"Mater Des"},{"key":"10.1016\/j.prosdent.2026.09.010_bib24","doi-asserted-by":"crossref","first-page":"171","DOI":"10.4047\/jap.2023.15.4.171","article-title":"Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses","volume":"15","author":"Subsomboon","year":"2023","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.prosdent.2026.09.010_bib25","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.dental.2005.12.008","article-title":"Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges","volume":"23","author":"Studart","year":"2007","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib26","doi-asserted-by":"crossref","first-page":"e155","DOI":"10.1016\/j.dental.2016.12.010","article-title":"Effects of two grading techniques of zirconia material on the fatigue limit of full-contour 3-unit fixed dental prostheses","volume":"33","author":"Villefort","year":"2017","journal-title":"Dent Mater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib27","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2023.105736","article-title":"Fatigue performance analysis of strength-graded zirconia polycrystals for monolithic three-unit implant-supported prostheses","volume":"140","author":"Marini","year":"2023","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.prosdent.2026.09.010_bib28","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jmbbm.2013.01.005","article-title":"Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading","volume":"20","author":"Ozcan","year":"2013","journal-title":"J Mech Behav Biomed Mater"}],"container-title":["The Journal of Prosthetic Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326006414?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0022391326006414?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:10:22Z","timestamp":1791580222000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022391326006414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":28,"alternative-id":["S0022391326006414"],"URL":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.09.010","relation":{},"ISSN":["0022-3913"],"issn-type":[{"value":"0022-3913","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of connector dimensions and span length on fracture resistance of high-translucency 4Y-TZP: An in vitro and finite element study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Prosthetic Dentistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prosdent.2026.09.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2026 The Authors. Published by Elsevier Inc. on behalf of the Editorial Council of The Journal of Prosthetic Dentistry.","name":"copyright","label":"Copyright"}]}}