{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T19:04:31Z","timestamp":1762542271173,"version":"build-2065373602"},"reference-count":16,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["practicalradonc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Practical Radiation Oncology"],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1016\/j.prro.2014.03.010","type":"journal-article","created":{"date-parts":[[2014,5,14]],"date-time":"2014-05-14T11:01:01Z","timestamp":1400065261000},"page":"43-48","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effect of metal hip prosthesis on the accuracy of electromagnetic localization tracking"],"prefix":"10.1016","volume":"5","author":[{"given":"Nathan","family":"Bittner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wayne M.","family":"Butler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian S.","family":"Kurko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory S.","family":"Merrick","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prro.2014.03.010_bb0005","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/S0360-3016(01)01453-5","article-title":"Organ motion and its management","volume":"50","author":"Langen","year":"2001","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0010","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.ijrobp.2007.03.029","article-title":"Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers","volume":"69","author":"Kotte","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0015","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/j.ijrobp.2010.02.001","article-title":"Assessment of planning target volume margins for intensity-modulated radiotherapy of the prostate gland: Role of daily inter- and intrafraction motion","volume":"78","author":"Tanyi","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0020","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.ijrobp.2009.03.036","article-title":"Daily isocenter correction with electromagnetic-based localization improves target coverage and rectal sparing during prostate radiotherapy","volume":"76","author":"Rajendran","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0025","unstructured":"Hypofractionated Stereotactic Body Radiation Therapy (SBRT). Available at: http:\/\/clinicaltrials.gov\/show\/NCT01288534. Accessed April 16, 2014."},{"key":"10.1016\/j.prro.2014.03.010_bb0030","unstructured":"SEER Stat Fact Sheets: Prostate Cancer. Available at: http:\/\/seer.cancer.gov\/statfacts\/html\/prost.html. Accessed April 16, 2014."},{"key":"10.1016\/j.prro.2014.03.010_bb0035","doi-asserted-by":"crossref","first-page":"526","DOI":"10.2106\/00004623-200703000-00009","article-title":"Incidence and short-term outcomes of primary and revision hip replacement in the United States","volume":"89","author":"Zhan","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.prro.2014.03.010_bb0040","doi-asserted-by":"crossref","first-page":"e2383","DOI":"10.1136\/bmj.e2383","article-title":"Risk of cancer in first seven years after metal-on-metal hip replacement compared with other bearings and general population: Linkage study between the National Joint Registry of England and Wales and hospital episode statistics","volume":"344","author":"Smith","year":"2012","journal-title":"BMJ"},{"key":"10.1016\/j.prro.2014.03.010_bb0045","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1001\/jama.2011.478","article-title":"Clinical characteristics and outcomes of Medicare patients undergoing total hip arthroplasty, 1991-2008","volume":"305","author":"Cram","year":"2011","journal-title":"JAMA"},{"key":"10.1016\/j.prro.2014.03.010_bb0050","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.ijrobp.2006.01.050","article-title":"Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer","volume":"65","author":"Willoughby","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0055","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1016\/j.urology.2009.10.072","article-title":"Reduction in patient-reported acute morbidity in prostate cancer patients treated with 81-Gy intensity-modulated radiotherapy using reduced planning target volume margins and electromagnetic tracking: Assessing the impact of margin reduction study","volume":"75","author":"Sandler","year":"2010","journal-title":"Urology"},{"key":"10.1016\/j.prro.2014.03.010_bb0060","doi-asserted-by":"crossref","first-page":"e173","DOI":"10.1016\/j.ijrobp.2011.08.044","article-title":"Effect of body mass index on intrafraction prostate displacement monitored by real-time electromagnetic tracking","volume":"84","author":"Butler","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0065","doi-asserted-by":"crossref","first-page":"4141","DOI":"10.1120\/jacmp.v14i2.4141","article-title":"Intrafraction displacement of prone versus supine prostate positioning monitored by real-time electromagnetic tracking","volume":"14","author":"Butler","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0070","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.urolonc.2008.04.017","article-title":"Prostate tumor alignment and continuous, real-time adaptive radiation therapy using electromagnetic fiducials: Clinical and cost-utility analyses","volume":"27","author":"Quigley","year":"2009","journal-title":"Urol Oncol"},{"key":"10.1016\/j.prro.2014.03.010_bb0075","doi-asserted-by":"crossref","first-page":"4807","DOI":"10.1118\/1.4736976","article-title":"An evaluation of interference of inflatable penile prostheses with electromagnetic localization and tracking system","volume":"39","author":"Wang","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.prro.2014.03.010_bb0080","doi-asserted-by":"crossref","first-page":"2450","DOI":"10.1118\/1.3578602","article-title":"Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: A phantom study","volume":"38","author":"Su","year":"2011","journal-title":"Med Phys"}],"container-title":["Practical Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850014000708?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850014000708?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T10:19:04Z","timestamp":1761819544000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1879850014000708"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["S1879850014000708"],"URL":"https:\/\/doi.org\/10.1016\/j.prro.2014.03.010","relation":{},"ISSN":["1879-8500"],"issn-type":[{"type":"print","value":"1879-8500"}],"subject":[],"published":{"date-parts":[[2015,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of metal hip prosthesis on the accuracy of electromagnetic localization tracking","name":"articletitle","label":"Article Title"},{"value":"Practical Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prro.2014.03.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}