{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T12:15:02Z","timestamp":1770293702693,"version":"3.49.0"},"reference-count":13,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,3,1]],"date-time":"2017-03-01T00:00:00Z","timestamp":1488326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,3,1]],"date-time":"2017-03-01T00:00:00Z","timestamp":1488326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["practicalradonc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Practical Radiation Oncology"],"published-print":{"date-parts":[[2017,3]]},"DOI":"10.1016\/j.prro.2016.07.004","type":"journal-article","created":{"date-parts":[[2016,7,18]],"date-time":"2016-07-18T00:17:29Z","timestamp":1468801049000},"page":"e109-e116","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["Receiver operating curves and dose-volume analysis of late toxicity with stereotactic body radiation therapy for prostate cancer"],"prefix":"10.1016","volume":"7","author":[{"given":"Li","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julian","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander R.","family":"Gottschalk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert J.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I-Chow","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"III","given":"Mack","family":"Roach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zachary A.","family":"Seymour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.prro.2016.07.004_bb0005","doi-asserted-by":"crossref","first-page":"e465","DOI":"10.1016\/j.prro.2015.02.001","article-title":"Dose-volume analysis and the temporal nature of toxicity with stereotactic body radiation therapy for prostate cancer","volume":"5","author":"Seymour","year":"2015","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.prro.2016.07.004_bb0010","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.prro.2015.01.006","article-title":"Dosimetric parameters predict short-term quality-of-life outcomes for patients receiving stereotactic body radiation therapy for prostate cancer","volume":"5","author":"Gomez","year":"2015","journal-title":"Pract Radiat Oncol"},{"issue":"3 Suppl.","key":"10.1016\/j.prro.2016.07.004_bb0015","doi-asserted-by":"crossref","first-page":"e31s","DOI":"10.1200\/JOP.2012.000548","article-title":"Cost effectiveness analysis of stereotactic body radiation therapy versus intensity-modulated radiation therapy: An emerging initial radiation treatment option for organ-confined prostate cancer","volume":"8","author":"Hodges","year":"2012","journal-title":"J Oncol Pract"},{"key":"10.1016\/j.prro.2016.07.004_bb0020","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.prro.2013.02.011","article-title":"Dosimetric analysis of radiation therapy oncology group 0321: The importance of urethral dose","volume":"4","author":"Hsu","year":"2014","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.prro.2016.07.004_bb0025","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/1748-717X-8-58","article-title":"Stereotactic body radiation therapy (SBRT) for clinically localized prostate cancer: The Georgetown University experience","volume":"8","author":"Chen","year":"2013","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.prro.2016.07.004_bb0030","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S0360-3016(99)00176-5","article-title":"Urinary morbidity following ultrasound-guided transperineal prostate seed implantation","volume":"45","author":"Gelblum","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2016.07.004_bb0035","doi-asserted-by":"crossref","first-page":"52","DOI":"10.3109\/0284186X.2015.1037011","article-title":"Late urinary toxicity modeling after stereotactic body radiotherapy (SBRT) in the definitive treatment of localized prostate cancer","volume":"55","author":"Kole","year":"2016","journal-title":"Acta Oncol"},{"key":"10.1016\/j.prro.2016.07.004_bb0040","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1120\/jacmp.v14i5.4333","article-title":"Improving plan quality and consistency by standardization of dose constraints in prostate cancer patients treated with CyberKnife","volume":"14","author":"Descovich","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.prro.2016.07.004_bb0045","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1016\/j.ijrobp.2007.11.067","article-title":"Virtual HDR SM CyberKnife treatment for localized prostatic carcinoma: Dosimetry comparison with HDR brachytherapy and preliminary clinical observations","volume":"70","author":"Fuller","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2016.07.004_bb0050","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.ijrobp.2010.11.054","article-title":"Long-term outcomes from a prospective trial of stereotactic body radiotherapy for low-risk prostate cancer","volume":"82","author":"King","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2016.07.004_bb0055","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/S0360-3016(01)02657-8","article-title":"Risk factors for acute urinary retention requiring temporary intermittent catheterization after prostate brachytherapy: A prospective study","volume":"52","author":"Locke","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2016.07.004_bb0060","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/S0302-2838(03)00134-9","article-title":"The impact of prostate volume following neoadjuvant androgen deprivation on quality of life and voiding symptoms in patients undergoing permanent prostate brachytherapy","volume":"43","author":"Krupski","year":"2003","journal-title":"Eur Urol"},{"key":"10.1016\/j.prro.2016.07.004_bb0065","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1186\/s13014-014-0241-3","article-title":"Stereotactic body radiation therapy (SBRT) for prostate cancer in men with large prostates (\u226550 cm3)","volume":"9","author":"Janowski","year":"2014","journal-title":"Radiat Oncol"}],"container-title":["Practical Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850016301151?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850016301151?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T10:20:11Z","timestamp":1761819611000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1879850016301151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,3]]}},"alternative-id":["S1879850016301151"],"URL":"https:\/\/doi.org\/10.1016\/j.prro.2016.07.004","relation":{},"ISSN":["1879-8500"],"issn-type":[{"value":"1879-8500","type":"print"}],"subject":[],"published":{"date-parts":[[2017,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Receiver operating curves and dose-volume analysis of late toxicity with stereotactic body radiation therapy for prostate cancer","name":"articletitle","label":"Article Title"},{"value":"Practical Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prro.2016.07.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}