{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T12:13:25Z","timestamp":1788178405657,"version":"build-2803163510"},"reference-count":34,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T00:00:00Z","timestamp":1778716800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100025178","name":"OpenAI","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100025178","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","practicalradonc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Practical Radiation Oncology"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.prro.2026.05.004","type":"journal-article","created":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T16:19:12Z","timestamp":1778861952000},"page":"e401-e412","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Intrafraction Motion Mitigation by Rectal Spacers in Prostate Stereotactic Body Radiation Therapy: Balloon, Hydrogel, and No-Spacer Comparison"],"prefix":"10.1016","volume":"16","author":[{"given":"Benjamin V.","family":"Tward","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Szegedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7765-4473","authenticated-orcid":false,"given":"Jonathan D.","family":"Tward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prro.2026.05.004_bib0001","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.prro.2023.08.017","article-title":"Monitoring intrafraction motion of the prostate during radiation therapy: Suggested practice points from a focused review","volume":"14","author":"Shimomura","year":"2024","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0002","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1177\/153303461000900502","article-title":"The CyberKnife robotic radiosurgery system in 2010","volume":"9","author":"Kilby","year":"2010","journal-title":"Technol Cancer Res Treat"},{"key":"10.1016\/j.prro.2026.05.004_bib0003","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.ijrobp.2006.01.050","article-title":"Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer","volume":"65","author":"Willoughby","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0004","doi-asserted-by":"crossref","first-page":"7485","DOI":"10.1088\/0031-9155\/60\/19\/7485","article-title":"A new methodology for inter- and intrafraction plan adaptation for the MR-linac","volume":"60","author":"Kontaxis","year":"2015","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.prro.2026.05.004_bib0005","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.ijrobp.2007.11.054","article-title":"Observations on real-time prostate gland motion using electromagnetic tracking","volume":"71","author":"Langen","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0006","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.radonc.2018.01.001","article-title":"The first clinical implementation of real-time image-guided adaptive radiotherapy using a standard linear accelerator","volume":"127","author":"Keall","year":"2018","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0007","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.ijrobp.2015.04.030","article-title":"Hydrogel spacer prospective multicenter randomized controlled pivotal trial: Dosimetric and clinical effects of perirectal spacer application in men undergoing prostate image guided intensity modulated radiation therapy","volume":"92","author":"Mariados","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0008","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1001\/jamaoncol.2022.7592","article-title":"Hyaluronic acid spacer for hypofractionated prostate radiation therapy: A randomized clinical trial","volume":"9","author":"Mariados","year":"2023","journal-title":"JAMA Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0009","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1016\/j.ijrobp.2024.07.2145","article-title":"Prospective, randomized controlled pivotal trial of biodegradable balloon rectal spacer for prostate radiation therapy","volume":"120","author":"Song","year":"2024","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0010","doi-asserted-by":"crossref","first-page":"S82","DOI":"10.1016\/j.ijrobp.2025.06.1105","article-title":"Long-term toxicity and patient-reported quality of life after prostate IMRT with or without biodegradable balloon rectal spacer: Analysis of a pivotal randomized trial","volume":"123","author":"Song","year":"2025","journal-title":"Int J Radiat Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0011","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1016\/j.ijrobp.2023.12.035","article-title":"Quantifying intrafraction motion and the impact of gating for magnetic resonance imaging-guided stereotactic radiation therapy for prostate cancer: Analysis of the magnetic resonance imaging arm from the MIRAGE phase 3 randomized trial","volume":"118","author":"Neylon","year":"2024","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"2","key":"10.1016\/j.prro.2026.05.004_bib0012","doi-asserted-by":"crossref","first-page":"e210","DOI":"10.1016\/j.prro.2020.04.014","article-title":"Triggered imaging with auto beam hold and pre-\/posttreatment CBCT during prostate SABR: Analysis of time efficiency, target coverage, and normal volume changes","volume":"11","author":"Kisivan","year":"2021","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0013","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1016\/j.ijrobp.2015.10.009","article-title":"Real-time 3D image guidance using a standard LINAC: Measured motion, accuracy, and precision of the first prospective clinical trial of kilovoltage intrafraction monitoring-guided gating for prostate cancer radiation therapy","volume":"94","author":"Keall","year":"2016","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0014","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.ijrobp.2025.05.066","article-title":"Dosimetric comparison of magnetic resonance imaging guided versus reduced margin computed tomography guided stereotactic body radiation therapy for localized prostate cancer: Post hoc analysis of a phase 3 trial","volume":"125","author":"Courtney","year":"2026","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0015","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.radi.2017.07.003","article-title":"Intrafraction monitoring of prostate motion during radiotherapy using the Clarity\u00ae Autoscan transperineal ultrasound (TPUS) system","volume":"23","author":"Richardson","year":"2017","journal-title":"Radiography (Lond)"},{"key":"10.1016\/j.prro.2026.05.004_bib0016","first-page":"203","article-title":"Visualisation of Mahalanobis distances for trivariate JOINT distributions","volume":"14","author":"Groenewald","year":"2024","journal-title":"Int J Econ Financ Issues"},{"key":"10.1016\/j.prro.2026.05.004_bib0017","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/S0360-3016(03)00501-7","article-title":"Late rectal function after prostate brachytherapy","volume":"57","author":"Merrick","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0018","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1016\/S0022-5347(17)36966-5","article-title":"The American Urological Association symptom index for benign prostatic hyperplasia. The Measurement Committee of the American Urological Association","volume":"148","author":"Barry","year":"1992","journal-title":"J Urol"},{"key":"10.1016\/j.prro.2026.05.004_bib0019","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1038\/sj.ijir.3900472","article-title":"Development and evaluation of an abridged, 5-item version of the International Index of Erectile Function (IIEF-5) as a diagnostic tool for erectile dysfunction","volume":"11","author":"Rosen","year":"1999","journal-title":"Int J Impot Res"},{"key":"10.1016\/j.prro.2026.05.004_bib0020","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1186\/s12885-024-12692-x","article-title":"Long-term evaluation of the safety of a rectal-prostate spacer, the ProSpace\u00ae balloon, in patients treated with radiotherapy for prostate cancer","volume":"24","author":"Janoray","year":"2024","journal-title":"BMC Cancer"},{"key":"10.1016\/j.prro.2026.05.004_bib0021","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2021.701998","article-title":"Use of a biodegradable, contrast-filled rectal spacer balloon in intensity-modulated radiotherapy for intermediate-risk prostate cancer patients: Dosimetric gains in the BioPro-RCMI-1505 study","volume":"11","author":"Latorzeff","year":"2021","journal-title":"Front Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0022","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.ijrobp.2016.12.024","article-title":"Continued benefit to rectal separation for prostate radiation therapy: Final results of a Phase III trial","volume":"97","author":"Hamstra","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0023","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.clon.2011.01.511","article-title":"In pursuit of individualised margins for prostate cancer patients undergoing image-guided radiotherapy: The effect of body mass index on intrafraction prostate motion","volume":"23","author":"Thompson","year":"2011","journal-title":"Clin Oncol (R Coll Radiol)"},{"key":"10.1016\/j.prro.2026.05.004_bib0024","doi-asserted-by":"crossref","first-page":"e173","DOI":"10.1016\/j.ijrobp.2011.08.044","article-title":"Effect of body mass index on intrafraction prostate displacement monitored by real-time electromagnetic tracking","volume":"84","author":"Butler","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0025","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1002\/jmrs.255","article-title":"Obesity does not influence prostate intrafractional motion","volume":"65","author":"Brown","year":"2018","journal-title":"J Med Radiat Sci"},{"key":"10.1016\/j.prro.2026.05.004_bib0026","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20210521","article-title":"Impact of hydrogel peri-rectal spacer insertion on seminal vesicles intrafraction motion during 1.5\u2009T-MRI-guided adaptive stereotactic body radiotherapy for localized prostate cancer","volume":"94","author":"Mazzola","year":"2021","journal-title":"Br J Radiol"},{"key":"10.1016\/j.prro.2026.05.004_bib0027","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/s00066-020-01633-9","article-title":"Effectiveness of rectal displacement devices in managing prostate motion: A systematic review","volume":"197","author":"Afkhami Ardekani","year":"2021","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.prro.2026.05.004_bib0028","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1186\/s13014-015-0526-1","article-title":"Prostate motion during radiotherapy of prostate cancer patients with and without application of a hydrogel spacer: A comparative study","volume":"10","author":"Juneja","year":"2015","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0029","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1016\/j.ijrobp.2010.08.052","article-title":"Real-time study of prostate intrafraction motion during external beam radiotherapy with daily endorectal balloon","volume":"81","author":"Both","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0030","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1016\/j.ijrobp.2011.07.038","article-title":"A study to quantify the effectiveness of daily endorectal balloon for prostate intrafraction motion management","volume":"83","author":"Wang","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0031","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.ijrobp.2011.07.028","article-title":"An endorectal balloon reduces intrafraction prostate motion during radiotherapy","volume":"83","author":"Smeenk","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.prro.2026.05.004_bib0032","first-page":"227","article-title":"Emerging evidence for the role of an endorectal balloon in prostate radiation therapy","volume":"1","author":"Both","year":"2012","journal-title":"Transl Cancer Res"},{"key":"10.1016\/j.prro.2026.05.004_bib0033","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1186\/s13014-020-01622-3","article-title":"Impact of hydrogel peri-rectal spacer insertion on prostate gland intra-fraction motion during 1.5\u2009T MR-guided stereotactic body radiotherapy","volume":"15","author":"Cuccia","year":"2020","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.prro.2026.05.004_bib0034","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s13014-022-02008-3","article-title":"Injection of hydrogel spacer increased maximal intrafractional prostate motion in anterior and superior directions during volumetric modulated arc therapy-stereotactic body radiation therapy for prostate cancer","volume":"17","author":"Sawayanagi","year":"2022","journal-title":"Radiat Oncol"}],"container-title":["Practical Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850026001475?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850026001475?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T11:13:33Z","timestamp":1788174813000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1879850026001475"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":34,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S1879850026001475"],"URL":"https:\/\/doi.org\/10.1016\/j.prro.2026.05.004","relation":{},"ISSN":["1879-8500"],"issn-type":[{"value":"1879-8500","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Intrafraction Motion Mitigation by Rectal Spacers in Prostate Stereotactic Body Radiation Therapy: Balloon, Hydrogel, and No-Spacer Comparison","name":"articletitle","label":"Article Title"},{"value":"Practical Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prro.2026.05.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.","name":"copyright","label":"Copyright"}]}}