{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T12:38:51Z","timestamp":1793104731740,"version":"4.5.0"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","practicalradonc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Practical Radiation Oncology"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.prro.2026.09.008","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T23:47:39Z","timestamp":1789688859000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Excessive Bladder Filling at Simulation Correlates With Longer Treatment Times, More Interruptions, and Inferior Patient Experiences During Prostate Cancer Radiation Therapy"],"prefix":"10.1016","author":[{"given":"Thomas P.","family":"Howard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel G.","family":"Barkyoumb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jillian","family":"Connolly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Hui","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anurag","family":"Saraf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan E.","family":"Leeman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul L.","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shalini","family":"Moningi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Orio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5678-1251","authenticated-orcid":false,"given":"Luke","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.prro.2026.09.008_bib0001","doi-asserted-by":"crossref","DOI":"10.1200\/JCO.18.01097","article-title":"Hypofractionated radiation therapy for localized prostate cancer: An ASTRO, ASCO, and AUA evidence-based guideline","volume":"36","author":"Morgan","year":"2018","journal-title":"J Clin Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0002","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1016\/S1470-2045(19)30569-8","article-title":"Intensity-modulated fractionated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-B): acute toxicity findings from an international, randomised, open-label, phase 3, non-inferiority trial","volume":"20","author":"Brand","year":"2019","journal-title":"Lancet Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0003","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1001\/jamaoncol.2022.6558","article-title":"Magnetic resonance imaging-guided vs computed tomography-guided stereotactic body radiotherapy for prostate cancer: the MIRAGE randomized clinical trial","volume":"9","author":"Kishan","year":"2023","journal-title":"JAMA Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0004","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1056\/NEJMoa2403365","article-title":"Phase 3 trial of stereotactic body radiotherapy in localized prostate cancer","volume":"391","author":"van As","year":"2024","journal-title":"N Engl J Med"},{"key":"10.1016\/j.prro.2026.09.008_bib0005","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1016\/S1470-2045(25)00205-0","article-title":"Intensity-modulated moderately hypofractionated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-C): early toxicity results from a randomised, open-label, phase 3, non-inferiority trial","volume":"26","author":"Tree","year":"2025","journal-title":"Lancet Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0006","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1007\/s00066-011-2259-x","article-title":"Physical and clinical implications of radiotherapy treatment of prostate cancer using a full bladder protocol","volume":"187","author":"Cambria","year":"2011","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.prro.2026.09.008_bib0007","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1007\/s00066-017-1163-4","article-title":"Impact of a rectal and bladder preparation protocol on prostate cancer outcome in patients treated with external beam radiotherapy","volume":"193","author":"Maggio","year":"2017","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.prro.2026.09.008_bib0008","article-title":"Bowel and bladder reproducibility in image guided radiation therapy for prostate cancer: results of a patterns of practice survey","volume":"7","author":"Rowe","year":"2022","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0009","doi-asserted-by":"crossref","first-page":"e203","DOI":"10.1016\/j.prro.2013.11.006","article-title":"A randomized trial comparing bladder volume consistency during fractionated prostate radiation therapy","volume":"4","author":"Mullaney","year":"2014","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0010","article-title":"Predictors of successful first-attempt prostate cancer computed tomography simulation: a prospective cohort study","volume":"11","author":"George","year":"2026","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0011","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.radonc.2006.05.007","article-title":"Variability of bladder filling in patients receiving radical radiotherapy to the prostate","volume":"79","author":"O\u2019Doherty","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0012","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1259\/bjr\/50048151","article-title":"Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer","volume":"84","author":"Hynds","year":"2011","journal-title":"Br J Radiol"},{"key":"10.1016\/j.prro.2026.09.008_bib0013","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2023.1200270","article-title":"Assessment of bladder filling during prostate cancer radiation therapy with ultrasound and cone-beam CT","volume":"13","author":"Chauhan","year":"2023","journal-title":"Front Oncol"},{"key":"10.1016\/j.prro.2026.09.008_bib0014","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1002\/jmrs.162","article-title":"Use of a prospective cohort study in the development of a bladder scanning protocol to assist in bladder filling consistency for prostate cancer patients receiving radiation therapy","volume":"63","author":"Cramp","year":"2016","journal-title":"J Med Radiat Sci"},{"key":"10.1016\/j.prro.2026.09.008_bib0015","doi-asserted-by":"crossref","DOI":"10.1177\/1533033821995277","article-title":"BladderScan feedback method in predicting bladder filling for prostate radiotherapy: a prospective study","volume":"20","author":"Kuo","year":"2021","journal-title":"Technol Cancer Res Treat"},{"key":"10.1016\/j.prro.2026.09.008_bib0016","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00066-018-1398-8","article-title":"Impact of bladder volume on acute genitourinary toxicity in intensity modulated radiotherapy for localized and locally advanced prostate cancer","volume":"195","author":"Grun","year":"2019","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.prro.2026.09.008_bib0017","doi-asserted-by":"crossref","DOI":"10.2196\/51061","article-title":"A Smart Water Bottle and Companion App (HidrateSpark 3) to improve bladder-filling compliance in patients with prostate cancer receiving radiotherapy: nonrandomized trial of feasibility and acceptability","volume":"10","author":"Jin","year":"2024","journal-title":"JMIR Cancer"}],"container-title":["Practical Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850026002870?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1879850026002870?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T12:26:13Z","timestamp":1793103973000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1879850026002870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":17,"alternative-id":["S1879850026002870"],"URL":"https:\/\/doi.org\/10.1016\/j.prro.2026.09.008","relation":{},"ISSN":["1879-8500"],"issn-type":[{"value":"1879-8500","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Excessive Bladder Filling at Simulation Correlates With Longer Treatment Times, More Interruptions, and Inferior Patient Experiences During Prostate Cancer Radiation Therapy","name":"articletitle","label":"Article Title"},{"value":"Practical Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.prro.2026.09.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 American Society for Radiation Oncology. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}