{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T23:33:31Z","timestamp":1779924811179,"version":"3.53.1"},"reference-count":17,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T00:00:00Z","timestamp":1684713600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiology Case Reports"],"published-print":{"date-parts":[[2023,8]]},"DOI":"10.1016\/j.radcr.2023.05.050","type":"journal-article","created":{"date-parts":[[2023,6,10]],"date-time":"2023-06-10T23:22:35Z","timestamp":1686439355000},"page":"2860-2863","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Double stent retriever technique for rescue recanalization in refractory large vessel occlusions"],"prefix":"10.1016","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5291-6606","authenticated-orcid":false,"given":"Ahmad Sulaiman","family":"Alwahdy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rifka Annisa","family":"Dongoran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.radcr.2023.05.050_bib0001","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1016\/S0140-6736(16)00163-X","article-title":"Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomized trials","volume":"387","author":"Goyal","year":"2016","journal-title":"Lancet"},{"key":"10.1016\/j.radcr.2023.05.050_bib0002","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.wneu.2020.05.268","article-title":"Double stent retriever (SR) technique: a novel mechanical thrombectomy technique to facilitate the device-clot interaction for refractory acute cerebral large vessel occlusions","volume":"141","author":"Imahori","year":"2020","journal-title":"World Neurosurg"},{"key":"10.1016\/j.radcr.2023.05.050_bib0003","doi-asserted-by":"crossref","first-page":"e24993","DOI":"10.1097\/MD.0000000000024993","article-title":"Y-configuration double-stent-retriever thrombectomy for refractory thrombus in middle cerebral artery bifurcation","volume":"100","author":"Jiang","year":"2021","journal-title":"Medicine"},{"key":"10.1016\/j.radcr.2023.05.050_bib0004","doi-asserted-by":"crossref","first-page":"e747","DOI":"10.1016\/j.wneu.2018.12.023","article-title":"Increased success of single-1 pass large vessel recanalization using a combined stentriever and aspiration technique: a single institution study","volume":"123","author":"Colby","year":"2019","journal-title":"World Neurosurg"},{"key":"10.1016\/j.radcr.2023.05.050_bib0005","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1016\/j.jstrokecerebrovasdis.2015.10.005","article-title":"Double stent-retriever technique in endovascular treatment of middle cerebral artery Saddle Embolus","volume":"25","author":"Asadi","year":"2016","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"10.1016\/j.radcr.2023.05.050_bib0006","doi-asserted-by":"crossref","first-page":"552","DOI":"10.3174\/ajnr.A4133","article-title":"Double solitaire mechanical thrombectomy in acute stroke: effective rescue strategy for refractory artery occlusions?","volume":"36","author":"Klisch","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.radcr.2023.05.050_bib0007","doi-asserted-by":"crossref","first-page":"1848","DOI":"10.1016\/j.radcr.2022.03.023","article-title":"Crossing double stent retriever technique for refractory terminal internal carotid artery occlusion","volume":"17","author":"Sasaki","year":"2022","journal-title":"Radiol Case Rep"},{"key":"10.1016\/j.radcr.2023.05.050_bib0008","doi-asserted-by":"crossref","first-page":"E634","DOI":"10.1503\/cmaj.160472","article-title":"Dual-stent retrieval for mechanical thrombectomy of a refractory clot in acute stroke as a rescue technique","volume":"189","author":"Patro","year":"2017","journal-title":"Can Med Assoc J"},{"key":"10.1016\/j.radcr.2023.05.050_bib0009","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.3171\/2017.1.FOCUS16511","article-title":"Utility of a Y-configured stentriever technique as a rescue method of thrombectomy for an intractable rooted thrombus located on the middle cerebral artery bifurcation","volume":"42","author":"Okada","year":"2017","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.radcr.2023.05.050_bib0010","doi-asserted-by":"crossref","first-page":"22","DOI":"10.5469\/neuroint.2015.10.1.22","article-title":"Adjuvant tirofiban injection through deployed solitaire stent as a rescue technique after failed mechanical thrombectomy in acute stroke","volume":"10","author":"Seo","year":"2015","journal-title":"Neurointervention"},{"key":"10.1016\/j.radcr.2023.05.050_bib0011","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1161\/STROKEAHA.117.020072","article-title":"Rescue stenting for failed mechanical thrombectomy in acute ischemic stroke: a multicenter experience","volume":"49","author":"Chang","year":"2018","journal-title":"Stroke"},{"key":"10.1016\/j.radcr.2023.05.050_bib0012","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1136\/neurintsurg-2018-013918","article-title":"Longer stent retrievers enhance thrombectomy performance in acute stroke","volume":"11","author":"Haussen","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"10.1016\/j.radcr.2023.05.050_bib0013","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1161\/STROKEAHA.118.022987","article-title":"Impact of stent retriever size on clinical and angiographic outcomes in the STRATIS Stroke Thrombectomy Registry","volume":"50","author":"Zaidat","year":"2019","journal-title":"Stroke"},{"key":"10.1016\/j.radcr.2023.05.050_bib0014","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.3171\/2016.12.JNS161233","article-title":"Y-stent retriever\": a new rescue technique for refractory large-vessel occlusions?","volume":"128","author":"Corsa","year":"2018","journal-title":"J Neurosurg"},{"key":"10.1016\/j.radcr.2023.05.050_bib0015","doi-asserted-by":"crossref","first-page":"e303","DOI":"10.1016\/j.wneu.2018.12.087","article-title":"Stent expansion and in-stent thrombus sign in the Trevo stent retriever predict recanalization and possible etiology during mechanical thrombectomy: a case series of 50 patients with acute middle cerebral artery occlusion","volume":"124","author":"Imahori","year":"2018","journal-title":"World Neurosurg"},{"key":"10.1016\/j.radcr.2023.05.050_bib0016","doi-asserted-by":"crossref","first-page":"2170","DOI":"10.1016\/j.radcr.2022.03.086","article-title":"Dissective tandem stroke: an endovascular approach","volume":"17","author":"Guida","year":"2022","journal-title":"Radiol Case Rep"},{"key":"10.1016\/j.radcr.2023.05.050_bib0017","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.radcr.2022.10.017","article-title":"Acute internal carotid artery occlusion due to dissection of the paraclinoid segment: diagnostic usefulness of angiographic findings during stent retriever deployment","volume":"18","author":"Sasaki","year":"2023","journal-title":"Radiol Case Rep"}],"container-title":["Radiology Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1930043323003448?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1930043323003448?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T12:01:35Z","timestamp":1761825695000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1930043323003448"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2023,8]]}},"alternative-id":["S1930043323003448"],"URL":"https:\/\/doi.org\/10.1016\/j.radcr.2023.05.050","relation":{},"ISSN":["1930-0433"],"issn-type":[{"value":"1930-0433","type":"print"}],"subject":[],"published":{"date-parts":[[2023,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Double stent retriever technique for rescue recanalization in refractory large vessel occlusions","name":"articletitle","label":"Article Title"},{"value":"Radiology Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radcr.2023.05.050","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of University of Washington.","name":"copyright","label":"Copyright"}]}}