{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T03:49:32Z","timestamp":1791344972557,"version":"4.3.1"},"reference-count":39,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2024,5]]},"DOI":"10.1016\/j.radi.2024.04.013","type":"journal-article","created":{"date-parts":[[2024,4,29]],"date-time":"2024-04-29T17:15:05Z","timestamp":1714410905000},"page":"995-1000","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Contribution of CT scan to patient's radiation exposure in parathyroid SPECT\/CT scintigraphy"],"prefix":"10.1016","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2544-2123","authenticated-orcid":false,"given":"S.","family":"Rep","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Jensterle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.","family":"Zde\u0161ar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Zaletel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Tom\u0161e","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Le\u017eai\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.radi.2024.04.013_bib1","doi-asserted-by":"crossref","first-page":"2801","DOI":"10.1007\/s00259-021-05334-y","article-title":"The EANM practice guidelines for parathyroid imaging","volume":"48","author":"Petranovi\u0107 Ov\u010dari\u010dek","year":"2021","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1016\/j.radi.2024.04.013_bib2","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.2967\/jnumed.107.040428","article-title":"Comparison of SPECT\/CT, SPECT, and planar imaging with single- and dual-phase (99m)Tc-sestamibi parathyroid scintigraphy","volume":"48","author":"Lavely","year":"2007","journal-title":"J\u00a0Nucl Med"},{"key":"10.1016\/j.radi.2024.04.013_bib3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3348\/kjr.2012.13.1.1","article-title":"CT radiation dose optimization and estimation: an update for radiologists","volume":"13","author":"Goo","year":"2012","journal-title":"Korean J Radiol"},{"key":"10.1016\/j.radi.2024.04.013_bib4","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1097\/MNM.0b013e328355b6d5","article-title":"SPECT-CT in routine clinical practice: increase in patient radiation dose compared with SPECT alone","volume":"33","author":"Sharma","year":"2012","journal-title":"Nucl Med Commun"},{"key":"10.1016\/j.radi.2024.04.013_bib5","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1002\/acm2.13069","article-title":"On the optimization of bone SPECT\/CT in terms of image quality and radiation dose","volume":"21","author":"Tulik","year":"2020","journal-title":"J\u00a0Appl Clin Med Phys"},{"key":"10.1016\/j.radi.2024.04.013_bib6","doi-asserted-by":"crossref","first-page":"138","DOI":"10.2967\/jnmt.110.075770","article-title":"Assessment of patient exposure to X-radiation from SPECT\/CT scanners","volume":"38","author":"Hara","year":"2010","journal-title":"J Nucl Med Technol"},{"key":"10.1016\/j.radi.2024.04.013_bib7","doi-asserted-by":"crossref","first-page":"65","DOI":"10.2217\/iim.09.5","article-title":"Radiation dose reduction in computed tomography: techniques and future perspective","volume":"1","author":"Yu","year":"2009","journal-title":"Imaging Med"},{"key":"10.1016\/j.radi.2024.04.013_bib8","doi-asserted-by":"crossref","first-page":"E787","DOI":"10.3390\/diagnostics10100787","article-title":"Evaluation of impact of factors affecting CT radiation dose for optimizing patient dose levels","volume":"10","author":"Yang","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"10.1016\/j.radi.2024.04.013_bib9","doi-asserted-by":"crossref","first-page":"881","DOI":"10.2214\/AJR.09.3462","article-title":"Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning","volume":"194","author":"Christner","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.radi.2024.04.013_bib10","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography--an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.radi.2024.04.013_bib11","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1093\/rpd\/ncr261","article-title":"Radiation dose management in CT, SPECT\/CT and PET\/CT techniques","volume":"147","author":"Mattsson","year":"2011","journal-title":"Radiat Prot Dosimetry"},{"key":"10.1016\/j.radi.2024.04.013_bib12","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1007\/s12149-013-0724-6","article-title":"Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT\/CT explorations","volume":"27","author":"Montes","year":"2013","journal-title":"Ann Nucl Med"},{"key":"10.1016\/j.radi.2024.04.013_bib13","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/MNM.0b013e3282f258ef","article-title":"Effective doses to patients from CT acquisitions on the GE Infinia Hawkeye: a comparison of calculation methods","volume":"29","author":"Sawyer","year":"2008","journal-title":"Nucl Med Commun"},{"key":"10.1016\/j.radi.2024.04.013_bib14","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1016\/j.ejrad.2016.06.022","article-title":"Radiation exposure levels of routine SPECT\/CT imaging protocols","volume":"85","author":"Rausch","year":"2016","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.radi.2024.04.013_bib15","doi-asserted-by":"crossref","DOI":"10.1155\/2011\/897202","article-title":"Quantifying the increase in radiation exposure associated with SPECT\/CT compared to SPECT alone for routine nuclear medicine examinations","volume":"2011","author":"Larkin","year":"2011","journal-title":"Int J Mol Imaging"},{"key":"10.1016\/j.radi.2024.04.013_bib16","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/s40336-014-0093-8","article-title":"SPECT\/CT radiation dosimetry","volume":"2","author":"Ferrari","year":"2014","journal-title":"Clin Transl Imaging"},{"key":"10.1016\/j.radi.2024.04.013_bib17","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1097\/HP.0b013e31829db936","article-title":"Standardization versus individualization: how each contributes to managing dose in computed tomography","volume":"105","author":"McCollough","year":"2013","journal-title":"Health Phys"},{"key":"10.1016\/j.radi.2024.04.013_bib18","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0138658","article-title":"Optimization of SPECT-CT hybrid imaging using iterative image reconstruction for low-dose CT: a phantom study","volume":"10","author":"Grosser","year":"2015","journal-title":"PLoS One"},{"issue":"3","key":"10.1016\/j.radi.2024.04.013_bib19","doi-asserted-by":"crossref","first-page":"764","DOI":"10.2214\/AJR.09.2397","article-title":"Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study","volume":"193","author":"Hara","year":"2009","journal-title":"Am J Roentgenol"},{"key":"10.1016\/j.radi.2024.04.013_bib20","doi-asserted-by":"crossref","first-page":"229","DOI":"10.21037\/qims-21-215","article-title":"Effect of a new deep learning image reconstruction algorithm for abdominal computed tomography imaging on image quality and dose reduction compared with two iterative reconstruction algorithms: a phantom study","volume":"12","author":"Greffier","year":"2022","journal-title":"Quant Imaging Med Surg"},{"key":"10.1016\/j.radi.2024.04.013_bib21","doi-asserted-by":"crossref","DOI":"10.1148\/radiol.221257","article-title":"Deep learning image reconstruction for CT: technical principles and clinical prospects","volume":"306","author":"Koetzier","year":"2023","journal-title":"Radiology"},{"key":"10.1016\/j.radi.2024.04.013_bib22","doi-asserted-by":"crossref","first-page":"4238","DOI":"10.1007\/s00261-021-03111-x","article-title":"Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction","volume":"46","author":"Noda","year":"2021","journal-title":"Abdom Radiol (NY)"},{"key":"10.1016\/j.radi.2024.04.013_bib23","doi-asserted-by":"crossref","first-page":"2620","DOI":"10.1007\/s00330-021-08367-x","article-title":"Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography","volume":"32","author":"Benz","year":"2022","journal-title":"Eur Radiol"},{"key":"10.1016\/j.radi.2024.04.013_bib24","article-title":"Image quality improvement in low-dose chest CT with deep learning image reconstruction","volume":"23","author":"Tian","year":"2022","journal-title":"J\u00a0Appl Clin Med Phys"},{"key":"10.1016\/j.radi.2024.04.013_bib25","first-page":"266","article-title":"Estimation of radiation dosimetry\u00a0for some common SPECT-CT exams","volume":"1","author":"Mhiri","year":"2012","journal-title":"Int J Biotechnol Wellness Ind"},{"key":"10.1016\/j.radi.2024.04.013_bib26","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.ijscr.2019.04.005","article-title":"An anatomic aberration and a surgical challenge: mediastinal parathyroid adenoma anterior the pericardium. A case report","volume":"58","author":"Patrinos","year":"2019","journal-title":"Int J Surg Case Rep"},{"key":"10.1016\/j.radi.2024.04.013_bib27","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s40463-016-0165-z","article-title":"Ectopic parathyroid adenoma in the soft palate: a case report","volume":"45","author":"Chang","year":"2016","journal-title":"J\u00a0Otolaryngol Head Neck Surg"},{"key":"10.1016\/j.radi.2024.04.013_bib28","first-page":"156","article-title":"Primary hyperparathyroidism through an ectopic parathyroid adenoma","volume":"111","author":"Grozavu","year":"2016","journal-title":"Chirurgia (Bucur)"},{"key":"10.1016\/j.radi.2024.04.013_bib29","first-page":"1","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection. Ann. ICRP 37","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"10.1016\/j.radi.2024.04.013_bib30","first-page":"1","article-title":"1998 Recommendations of the International Commission on Radiological Protection, Ann. ICRP 21","volume":"28","year":"1998","journal-title":"Ann ICRP"},{"key":"10.1016\/j.radi.2024.04.013_bib31","series-title":"IBM SPSS Statistics for Windows","year":"2017"},{"key":"10.1016\/j.radi.2024.04.013_bib32","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1088\/1361-6498\/aaa86f","article-title":"18F-choline PET\/CT for parathyroid scintigraphy: significantly lower radiation exposure of patients in comparison to conventional nuclear medicine imaging approaches","volume":"38","author":"Rep","year":"2018","journal-title":"J Radiol Prot"},{"key":"10.1016\/j.radi.2024.04.013_bib33","doi-asserted-by":"crossref","first-page":"52","DOI":"10.4103\/wjnm.WJNM_29_18","article-title":"Low-radiation of technetium-99m-sestamibi and single-photon emission computed tomography\/computed tomography to diagnose parathyroid lesions","volume":"18","author":"Vaiman","year":"2019","journal-title":"World J Nucl Med"},{"key":"10.1016\/j.radi.2024.04.013_bib34","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.2214\/AJR.17.18674","article-title":"Dynamic CT for parathyroid adenoma detection: how does radiation dose compare with nuclear medicine?","volume":"210","author":"Czarnecki","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.radi.2024.04.013_bib35","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.jacr.2013.05.032","article-title":"CT scan parameters and radiation dose: practical advice for radiologists","volume":"10","author":"Raman","year":"2013","journal-title":"J Am Coll Radiol"},{"key":"10.1016\/j.radi.2024.04.013_bib36","doi-asserted-by":"crossref","first-page":"W49","DOI":"10.2214\/AJR.09.2878","article-title":"Dose reduction in helical CT: dynamically adjustable z-axis X-ray beam collimation","volume":"194","author":"Christner","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.radi.2024.04.013_bib37","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1067\/j.cpradiol.2018.05.010","article-title":"Radiation dose associated with over scanning in neck CT","volume":"48","author":"Badawy","year":"2019","journal-title":"Curr Probl Diagn Radiol"},{"key":"10.1016\/j.radi.2024.04.013_bib38","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1111\/1754-9485.12339","article-title":"Computed tomography overexposure as a consequence of extended scan length","volume":"59","author":"Badawy","year":"2015","journal-title":"J\u00a0Med Imaging Radiat Oncol"},{"key":"10.1016\/j.radi.2024.04.013_bib39","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation, Sources and effects of ionizing radiation, 2008, United Nations; New York, (published 2010). Unscear 2008 Report Volume I. United Nations: Scientific Committee on the Effects of Atomic Radiation www.unscear.org\/unscear\/uploads\/documents\/unscear-reports\/UNSCEAR_2008_Report_Vol.I-CORR.pdf."}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817424000907?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817424000907?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T21:15:42Z","timestamp":1715721342000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817424000907"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["S1078817424000907"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2024.04.013","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Contribution of CT scan to patient's radiation exposure in parathyroid SPECT\/CT scintigraphy","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2024.04.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}