{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:48:56Z","timestamp":1786996136555,"version":"build-2736575974"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T00:00:00Z","timestamp":1721865600000},"content-version":"vor","delay-in-days":54,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1016\/j.radi.2024.07.012","type":"journal-article","created":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T17:33:09Z","timestamp":1722879189000},"page":"94-101","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"S1","title":["Effect of patient characteristics on aortic attenuation in iodinated contrast-enhanced Abdominopelvic CT: A retrospective study"],"prefix":"10.1016","volume":"30","author":[{"given":"N.A.","family":"Varughese","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3725-6774","authenticated-orcid":false,"given":"N.C.","family":"Panakkal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0428-6926","authenticated-orcid":false,"given":"V.T.","family":"Nair","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Kadavigere","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Lakshmi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9345-9790","authenticated-orcid":false,"given":"S.","family":"Sukumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.radi.2024.07.012_bib1","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1148\/radiol.2332030994","article-title":"Multi-detector row CT: principles and practice for abdominal applications","volume":"233","author":"Saini","year":"2004","journal-title":"Radiology"},{"issue":"12","key":"10.1016\/j.radi.2024.07.012_bib2","doi-asserted-by":"crossref","first-page":"1314.e1","DOI":"10.1016\/j.crad.2016.07.009","article-title":"Comparison between a fixed-dose contrast protocol and a weight-based contrast dosing protocol in abdominal CT","volume":"71","author":"George","year":"2016","journal-title":"Clin Radiol"},{"issue":"3","key":"10.1016\/j.radi.2024.07.012_bib3","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jacr.2016.09.001","article-title":"Effect of fixed-volume and weight-based dosing regimens on the cost and volume of administered iodinated contrast material at abdominal CT","volume":"14","author":"Davenport","year":"2017","journal-title":"J\u00a0Am Coll Radiol"},{"issue":"6","key":"10.1016\/j.radi.2024.07.012_bib4","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.2214\/ajr.183.6.01831673","article-title":"Contrast-induced nephropathy","volume":"183","author":"Gleeson","year":"2004","journal-title":"AJR Am J Roentgenol"},{"issue":"8","key":"10.1016\/j.radi.2024.07.012_bib5","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1136\/heartjnl-2014-306962","article-title":"Contrast-induced nephropathy following angiography and cardiac interventions","volume":"102","author":"Rear","year":"2016","journal-title":"Heart"},{"issue":"1","key":"10.1016\/j.radi.2024.07.012_bib6","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s13244-021-00980-0","article-title":"Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols","volume":"12","author":"Caruso","year":"2021","journal-title":"Insights Imaging"},{"issue":"2","key":"10.1016\/j.radi.2024.07.012_bib7","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/RCT.0b013e31827dbc08","article-title":"Contrast enhancement during hepatic computed tomography: effect of total body weight, height, body mass index, blood volume, lean body weight, and body surface area","volume":"37","author":"Kidoh","year":"2013","journal-title":"J\u00a0Comput Assist Tomogr"},{"issue":"1","key":"10.1016\/j.radi.2024.07.012_bib8","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1148\/radiol.09090369","article-title":"Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume","volume":"254","author":"Kondo","year":"2010","journal-title":"Radiology"},{"issue":"3","key":"10.1016\/j.radi.2024.07.012_bib9","doi-asserted-by":"crossref","first-page":"777","DOI":"10.2214\/AJR.07.2765","article-title":"Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity","volume":"190","author":"Bae","year":"2008","journal-title":"Am J Roentgenol"},{"issue":"3","key":"10.1016\/j.radi.2024.07.012_bib10","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1148\/radiol.2015142941","article-title":"The optimal body size index with which to determine iodine dose for hepatic dynamic CT: a prospective multicenter study","volume":"278","author":"Awai","year":"2016","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.radi.2024.07.012_bib11","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1258\/ar.2012.120268","article-title":"Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures","volume":"53","author":"Svensson","year":"2012","journal-title":"Acta Radiol"},{"issue":"6","key":"10.1016\/j.radi.2024.07.012_bib12","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1258\/ar.2012.110657","article-title":"The influence of body mass index and gender on coronary arterial attenuation with fixed iodine load per body weight at dual-source CT coronary angiography","volume":"53","author":"Zhu","year":"2012","journal-title":"Acta Radiol"},{"issue":"4","key":"10.1016\/j.radi.2024.07.012_bib13","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.2214\/AJR.08.1407","article-title":"Effect of contrast injection protocols with dose adjusted to the estimated lean patient body weight on aortic enhancement at CT angiography","volume":"192","author":"Yanaga","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"10.1016\/j.radi.2024.07.012_bib14","first-page":"52","article-title":"Ethnicity, obesity and health pattern among Indian population","volume":"3","author":"Mungreiphy","year":"2012","journal-title":"J\u00a0Nat Sci Biol Med"},{"key":"10.1016\/j.radi.2024.07.012_bib15","first-page":"231","volume":"vol. 45","author":"Uppot","year":"2007"},{"issue":"2","key":"10.1016\/j.radi.2024.07.012_bib16","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1148\/radiol.2432060390","article-title":"Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?","volume":"243","author":"Ho","year":"2007","journal-title":"Radiology"},{"issue":"5","key":"10.1016\/j.radi.2024.07.012_bib17","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1177\/1078155215599669","article-title":"Comparison of two different formulas for body surface area in adults at extremes of height and weight","volume":"22","author":"Fancher","year":"2016","journal-title":"J\u00a0Oncol Pharm Pract"},{"key":"10.1016\/j.radi.2024.07.012_bib18","series-title":"StatPearls [Internet]","author":"Sharma","year":"2024"},{"issue":"6","key":"10.1016\/j.radi.2024.07.012_bib19","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1381\/096089206777346673","article-title":"Estimating blood volume in obese and morbidly obese patients","volume":"16","author":"Lemmens","year":"2006","journal-title":"Obes Surg"},{"issue":"3","key":"10.1016\/j.radi.2024.07.012_bib20","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1207\/s15327906mbr2603_7","article-title":"How many subjects does it take to do A regression analysis","volume":"26","author":"Green","year":"1991","journal-title":"Multivariate Behav Res"},{"key":"10.1016\/j.radi.2024.07.012_bib23","author":"Fox"},{"issue":"6","key":"10.1016\/j.radi.2024.07.012_bib24","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/j.acra.2019.07.014","article-title":"Dosing iodinated contrast media according to lean versus total body weight at abdominal CT: a stratified randomized controlled trial","volume":"27","author":"Costa","year":"2020","journal-title":"Acad Radiol"},{"issue":"7","key":"10.1016\/j.radi.2024.07.012_bib25","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1007\/s00330-013-2808-z","article-title":"Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight?","volume":"23","author":"Kondo","year":"2013","journal-title":"Eur Radiol"},{"key":"10.1016\/j.radi.2024.07.012_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2019.07.031","article-title":"Implementation of patient-tailored contrast volumes based on body surface area and heart rate harmonizes contrast enhancement and reduces contrast load in small patients in portal venous phase abdominal CT","volume":"121","author":"Walgraeve","year":"2019","journal-title":"Eur J Radiol"},{"issue":"2","key":"10.1016\/j.radi.2024.07.012_bib27","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1148\/radiol.10092086","article-title":"Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in\u00a0vitro and in\u00a0vivo study","volume":"256","author":"Schindera","year":"2010","journal-title":"Radiology"},{"issue":"1","key":"10.1016\/j.radi.2024.07.012_bib28","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.radi.2017.08.011","article-title":"Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: can image quality be maintained?","volume":"24","author":"Perrin","year":"2018","journal-title":"Radiography"},{"issue":"3","key":"10.1016\/j.radi.2024.07.012_bib29","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1148\/radiology.216.3.r00au43872","article-title":"Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model","volume":"216","author":"Bae","year":"2000","journal-title":"Radiology"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S107881742400186X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S107881742400186X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T17:34:10Z","timestamp":1762364050000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S107881742400186X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":27,"alternative-id":["S107881742400186X"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2024.07.012","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of patient characteristics on aortic attenuation in iodinated contrast-enhanced Abdominopelvic CT: A retrospective study","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2024.07.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers.","name":"copyright","label":"Copyright"}]}}