{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T16:39:35Z","timestamp":1782319175755,"version":"3.54.5"},"reference-count":33,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.radi.2025.102980","type":"journal-article","created":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T02:32:35Z","timestamp":1747362755000},"page":"102980","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Investigating the effect of thyroid shields and lead glasses on image quality and artefacts in cone beam computed tomography devices: A phantom study"],"prefix":"10.1016","volume":"31","author":[{"given":"L.","family":"Hafezi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9631-3081","authenticated-orcid":false,"given":"A.","family":"Aghaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.R.","family":"Deevband","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Vaezi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.radi.2025.102980_bib1","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1111\/prd.12161","article-title":"Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research","volume":"73","author":"Bornstein","year":"2000","journal-title":"Periodontology"},{"key":"10.1016\/j.radi.2025.102980_bib2","first-page":"7140","volume":"vol. 12","author":"Spagnuolo","year":"2022"},{"issue":"2","key":"10.1016\/j.radi.2025.102980_bib3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.17352\/2455-4634.000050","article-title":"A review on cone beam computed tomography in dentistry","volume":"7","author":"Nimeshkumar","year":"2021","journal-title":"Int J Oral Craniofac Sci"},{"issue":"1","key":"10.1016\/j.radi.2025.102980_bib4","first-page":"110","article-title":"Influence of lead apron shielding on absorbed doses from cone-beam computed tomography","volume":"175","author":"Rottke","year":"2017","journal-title":"Radiat Protect Dosim"},{"issue":"1","key":"10.1016\/j.radi.2025.102980_bib5","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.oooo.2023.01.011","article-title":"Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography","volume":"136","author":"Sar\u0131bal","year":"2023","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"10.1016\/j.radi.2025.102980_bib6","doi-asserted-by":"crossref","DOI":"10.1093\/dmfr\/twaf007","article-title":"Investigation of the effect of thyroid collar, radiation safety glasses and lead apron on radiation dose in cone beam computed tomography","author":"\u0130\u00e7\u00f6z","year":"2025","journal-title":"Dentomaxillofacial Radiol"},{"issue":"4","key":"10.1016\/j.radi.2025.102980_bib7","first-page":"707","article-title":"What is cone-beam CT and how does it work? Dental Clinics of","volume":"52","author":"Scarfe","year":"2008","journal-title":"North America"},{"issue":"10","key":"10.1016\/j.radi.2025.102980_bib8","doi-asserted-by":"crossref","DOI":"10.1088\/1748-0221\/16\/10\/P10011","article-title":"Patient-specific dose assessment using CBCT images and Monte Carlo calculations","volume":"16","author":"Aghaz","year":"2021","journal-title":"J Instrum"},{"key":"10.1016\/j.radi.2025.102980_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.radphyschem.2019.108347","article-title":"The use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in cbct exams using Monte Carlo","volume":"167","author":"Soares","year":"2020","journal-title":"Radiat Phys Chem"},{"key":"10.1016\/j.radi.2025.102980_bib10","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00411-017-0686-5","article-title":"The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography","volume":"56","author":"Akhlaghi","year":"2017","journal-title":"Radiat Environ Biophys"},{"issue":"3","key":"10.1016\/j.radi.2025.102980_bib11","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1088\/0031-9155\/21\/3\/004","article-title":"Beam hardening in x-ray reconstructive tomography","volume":"21","author":"Brooks","year":"1976","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.radi.2025.102980_bib12","first-page":"4103","article-title":"Diagnostic accuracy of cone-beam computed tomography (CBCT) in identifying periapical lesions: a comparative study with conventional radiography","volume":"10","author":"Kanneppady","year":"2025","journal-title":"J Pharm BioAllied Sci"},{"issue":"3","key":"10.1016\/j.radi.2025.102980_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.ortho.2023.100780","article-title":"The diagnostic accuracy of cone-beam computed tomography and two-dimensional imaging methods in the 3D localization and assessment of maxillary impacted canines compared to the gold standard in-vivo readings: a cross-sectional study","volume":"21","author":"Alfailany","year":"2023","journal-title":"Int Orthod"},{"key":"10.1016\/j.radi.2025.102980_bib14","series-title":"Health & science 2021-III","first-page":"207","article-title":"Cone beam computed tomography in dentistry","author":"Yavuz","year":"2009"},{"key":"10.1016\/j.radi.2025.102980_bib15","series-title":"Oral radiology-E-Book: principles and interpretation","author":"White","year":"2014"},{"key":"10.1016\/j.radi.2025.102980_bib16","series-title":"Radiologic science for technologists","author":"Bushong","year":"1988"},{"key":"10.1016\/j.radi.2025.102980_bib17","series-title":"Pro-project","article-title":"Pro-dent CT mk II - pro-project - 01-501","year":"2023"},{"key":"10.1016\/j.radi.2025.102980_bib18","first-page":"223","article-title":"Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners","volume":"15","author":"Aghaz","year":"2018","journal-title":"Iran J Med Phys"},{"issue":"6","key":"10.1016\/j.radi.2025.102980_bib19","doi-asserted-by":"crossref","DOI":"10.1259\/dmfr.20120260","article-title":"Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom","volume":"42","author":"Goren","year":"2013","journal-title":"Dentomaxillofacial Radiol"},{"key":"10.1016\/j.radi.2025.102980_bib20","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.ejmp.2017.05.069","article-title":"Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)","volume":"39","author":"de Las Heras Gala","year":"2017","journal-title":"Phys Med"},{"issue":"12","key":"10.1016\/j.radi.2025.102980_bib21","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1111\/clr.13019","article-title":"Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views","volume":"28","author":"Codari","year":"2017","journal-title":"Clin Oral Implants Res"},{"issue":"3","key":"10.1016\/j.radi.2025.102980_bib22","first-page":"113","article-title":"Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography","volume":"22","author":"Panjnoush","year":"2009","journal-title":"J Dent Med Tehran Univ Med Sci"},{"issue":"1","key":"10.1016\/j.radi.2025.102980_bib23","doi-asserted-by":"crossref","DOI":"10.1259\/dmfr.20140197","article-title":"Effective dose of dental CBCT\u2014a meta analysis of published data and additional data for nine CBCT units","volume":"44","author":"Ludlow","year":"2015","journal-title":"Dentomaxillofacial Radiol"},{"issue":"3","key":"10.1016\/j.radi.2025.102980_bib24","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1093\/rpd\/ncx008","article-title":"Effective dose in two different dental CBCT systems: Newtom VGi and Planmeca 3D mid","volume":"176","author":"Ghaedizirgar","year":"2017","journal-title":"Radiat Protect Dosim"},{"issue":"4","key":"10.1016\/j.radi.2025.102980_bib25","doi-asserted-by":"crossref","first-page":"281","DOI":"10.5624\/isd.2020.50.4.281","article-title":"Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: a CBCT-based study","volume":"50","author":"Ribas","year":"2020","journal-title":"Imag Sci Dent"},{"issue":"5","key":"10.1016\/j.radi.2025.102980_bib26","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1259\/dmfr\/30200901","article-title":"Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars","volume":"41","author":"Qu","year":"2012","journal-title":"Dentomaxillofacial Radiol"},{"issue":"2","key":"10.1016\/j.radi.2025.102980_bib27","doi-asserted-by":"crossref","first-page":"224","DOI":"10.26574\/maedica.2020.15.2.224","article-title":"Evaluation of the metal artifact caused by dental implants in cone beam computed tomography images","volume":"15","author":"Vahdani","year":"2020","journal-title":"Maedica"},{"issue":"6","key":"10.1016\/j.radi.2025.102980_bib28","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.oooo.2019.01.074","article-title":"Evaluation of artifacts generated by titanium, zirconium, and titanium\u2013zirconium alloy dental implants on MRI, CT, and CBCT images: a phantom study","volume":"127","author":"Kocasarac","year":"2019","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"10.1016\/j.radi.2025.102980_bib29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12880-019-0334-4","article-title":"Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities","volume":"19","author":"Shokri","year":"2019","journal-title":"BMC Med Imag"},{"issue":"2","key":"10.1016\/j.radi.2025.102980_bib30","doi-asserted-by":"crossref","first-page":"93","DOI":"10.5624\/isd.20200320","article-title":"Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: an integrative review","volume":"51","author":"Terrabuio","year":"2021","journal-title":"Imag Sci Dent"},{"issue":"3","key":"10.1016\/j.radi.2025.102980_bib31","first-page":"45","article-title":"Thyroid shield during brain CT scan: dose reduction and image quality evaluation","volume":"9","author":"Abuzaid","year":"2017","journal-title":"Imag Med"},{"issue":"4","key":"10.1016\/j.radi.2025.102980_bib32","article-title":"Radiation protection in dental imaging: evaluating the impact of the SABA thyroid shield during panoramic and cone beam computed tomography","volume":"17","author":"Bawazeer","year":"2024","journal-title":"J Radiat Res Appl Sci"},{"issue":"7","key":"10.1016\/j.radi.2025.102980_bib33","doi-asserted-by":"crossref","DOI":"10.1259\/dmfr.20190014","article-title":"Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use","volume":"48","author":"Pauwels","year":"2019","journal-title":"Dentomaxillofacial Radiol"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425001245?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425001245?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T14:29:43Z","timestamp":1754058583000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817425001245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":33,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["S1078817425001245"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2025.102980","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Investigating the effect of thyroid shields and lead glasses on image quality and artefacts in cone beam computed tomography devices: A phantom study","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2025.102980","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"102980"}}