{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:27:31Z","timestamp":1788222451852,"version":"build-2803163510"},"reference-count":27,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2025,10]]},"DOI":"10.1016\/j.radi.2025.103197","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T17:49:08Z","timestamp":1760636948000},"page":"103197","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Efficacy of antiperistaltic agents in improving image quality in pelvic magnetic resonance imaging: A systematic review and meta-analysis"],"prefix":"10.1016","volume":"31","author":[{"given":"N.M.","family":"Muhammad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1794-5898","authenticated-orcid":false,"given":"I.","family":"Garba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.S.","family":"Yahaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Abubakar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Mohammed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"11","key":"10.1016\/j.radi.2025.103197_bib1","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.crad.2007.05.007","article-title":"The value of hyoscine butylbromide in pelvic MRI","volume":"62","author":"Johnson","year":"2007","journal-title":"Clin Radiol"},{"issue":"10","key":"10.1016\/j.radi.2025.103197_bib2","doi-asserted-by":"crossref","first-page":"5374","DOI":"10.1007\/s00330-020-06869-8","article-title":"Patient preparation and image quality in female pelvic MRI: recommendations revisited","volume":"30","author":"Sheikh-Sarraf","year":"2020","journal-title":"Eur Radiol"},{"issue":"3","key":"10.1016\/j.radi.2025.103197_bib3","doi-asserted-by":"crossref","DOI":"10.1148\/rycan.220070","article-title":"Assessment of T2-weighted image quality at prostate MRI in patients with and those without intramuscular injection of glucagon","volume":"5","author":"Sundaram","year":"2023","journal-title":"Radiol Imaging Cancer"},{"key":"10.1016\/j.radi.2025.103197_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2022.110222","article-title":"Bowel preparation in MRI for detection of endometriosis: comparison of the effect of an enema, no additional medication and intravenous butylscopolamine on image quality","author":"Ciggaar","year":"2022","journal-title":"Europ J Radiol [Internet];"},{"key":"10.1016\/j.radi.2025.103197_bib5","doi-asserted-by":"crossref","unstructured":"Mart\u00ed-Bonmat\u00ed L, Graells M, Ronchera-Oms CL. Reduction of peristaltic artifacts on magnetic resonance imaging of the abdomen: a comparative evaluation of three drugs. Abdom Imaging. 1996 Jul-Aug;21(4):309\u201313. https:\/\/doi.org\/10.1007\/s002619900070. PMID: 8661572.","DOI":"10.1007\/s002619900070"},{"issue":"6","key":"10.1016\/j.radi.2025.103197_bib6","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1007\/s00330-011-2366-1","article-title":"Evaluation of the anti-peristaltic effect of glucagon and hyoscine on the small bowel: comparison of intravenous and intramuscular drug administration","volume":"22","author":"Gutzeit","year":"2012","journal-title":"Eur Radiol"},{"issue":"1","key":"10.1016\/j.radi.2025.103197_bib7","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s00330-017-4940-7","article-title":"Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate","volume":"28","author":"Ullrich","year":"2018","journal-title":"Eur Radiol"},{"issue":"8","key":"10.1016\/j.radi.2025.103197_bib8","doi-asserted-by":"crossref","first-page":"4002","DOI":"10.1007\/s00261-021-03046-3","article-title":"Value of bowel preparation techniques for prostate MRI: a preliminary study","volume":"46","author":"Schmidt","year":"2021","journal-title":"Abdom Radiol (NY)"},{"key":"10.1016\/j.radi.2025.103197_bib9","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"10.1016\/j.radi.2025.103197_bib10","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.b2535","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the prisma statement","volume":"339","author":"Moher","year":"2009","journal-title":"BMJ"},{"key":"10.1016\/j.radi.2025.103197_bib11","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jclinepi.2020.07.005","article-title":"Using the full PICO model as a search tool for systematic reviews resulted in lower recall for some PICO elements","volume":"127","author":"Frandsen","year":"2020","journal-title":"J Clin Epidemiol"},{"issue":"3","key":"10.1016\/j.radi.2025.103197_bib12","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1017\/S1460396917000693","article-title":"Magnetic resonance imaging in radiotherapy treatment target volumes definition for brain tumours: a systematic review and meta-analysis","volume":"17","author":"Abubakar","year":"2018","journal-title":"J Radiother Pract"},{"issue":"3","key":"10.1016\/j.radi.2025.103197_bib13","doi-asserted-by":"crossref","first-page":"494","DOI":"10.11124\/JBIES-22-00430","article-title":"The revised JBI critical appraisal tool for the assessment of risk of bias for randomized controlled trials","volume":"21","author":"Barker","year":"2023","journal-title":"JBI Evid Synth"},{"issue":"8","key":"10.1016\/j.radi.2025.103197_bib14","doi-asserted-by":"crossref","first-page":"302","DOI":"10.3390\/nursrep15080302","article-title":"Humanized and community-based nursing for geriatric care: impact, clinical contributions, and implementation barriers","volume":"15","author":"Espinel-Jara","year":"2025","journal-title":"Nurs Rep"},{"issue":"6","key":"10.1016\/j.radi.2025.103197_bib15","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1111\/ans.18252","article-title":"The effect of anti-spasmodic administration on the accuracy of magnetic resonance imaging staging of rectal cancer","volume":"93","author":"Taylor","year":"2023","journal-title":"ANZ J Surg"},{"issue":"2","key":"10.1016\/j.radi.2025.103197_bib16","doi-asserted-by":"crossref","first-page":"216.e9","DOI":"10.1016\/j.crad.2017.07.013","article-title":"Effect of hyoscine butylbromide on prostate multiparametric MRI anatomical and functional image quality","volume":"73","author":"Slough","year":"2018","journal-title":"Clin Radiol"},{"key":"10.1016\/j.radi.2025.103197_bib17","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.tipsro.2017.08.001","article-title":"Efficacy of butylscopolamine in obtaining clear MR image for intensity-modulated radiotherapy for prostate cancer","volume":"3\u20134","author":"Tanaka","year":"2017","journal-title":"Tech Innov Patient Support Radiat Oncol"},{"issue":"7","key":"10.1016\/j.radi.2025.103197_bib18","doi-asserted-by":"crossref","first-page":"259","DOI":"10.4329\/wjr.v5.i7.259","article-title":"Prostate magnetic resonance imaging at 3 Tesla: is administration of hyoscine-N-butyl-bromide mandatory?","volume":"5","author":"Roethke","year":"2013","journal-title":"World J Radiol"},{"issue":"2","key":"10.1016\/j.radi.2025.103197_bib19","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1002\/jmri.22252","article-title":"Effect of hyoscine butylbromide (HBB) on the uterine corpus: quantitative assessment with T2-weighted (T2W) MRI in healthy volunteers","volume":"32","author":"Fujimoto","year":"2010","journal-title":"J Magn Reson Imag"},{"issue":"6","key":"10.1016\/j.radi.2025.103197_bib20","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.crad.2010.02.007","article-title":"Effect of butylscopolamine on image quality in MRI of the prostate","volume":"65","author":"Wagner","year":"2010","journal-title":"Clin Radiol"},{"issue":"2","key":"10.1016\/j.radi.2025.103197_bib21","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1148\/radiol.2461062091","article-title":"Do anticholinergic agents suppress uterine peristalsis and sporadic myometrial contractions at cine MR imaging?","volume":"246","author":"Nakai","year":"2008","journal-title":"Radiology"},{"issue":"16","key":"10.1016\/j.radi.2025.103197_bib22","doi-asserted-by":"crossref","first-page":"2833","DOI":"10.3390\/cancers16162833","article-title":"Antispasmodic agents in magnetic resonance imaging of the urinary bladder\u2014a narrative review","volume":"16","author":"Sklinda","year":"2024","journal-title":"Cancers"},{"issue":"1","key":"10.1016\/j.radi.2025.103197_bib23","doi-asserted-by":"crossref","DOI":"10.1148\/rg.230085","article-title":"Body MRI pulse sequences: atlas and user guide","volume":"44","author":"Shetty","year":"2024","journal-title":"Radiographics"},{"issue":"4","key":"10.1016\/j.radi.2025.103197_bib24","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.radi.2014.03.014","article-title":"Psychophysical evaluation of Catphan\u00ae600 CT image quality findings using human observers and software analysis","volume":"20","author":"Zarb","year":"2014","journal-title":"Radiography"},{"issue":"3","key":"10.1016\/j.radi.2025.103197_bib25","doi-asserted-by":"crossref","first-page":"397","DOI":"10.3348\/kjr.2018.19.3.397","article-title":"Pelvic MRI: is endovaginal or rectal filling needed?","volume":"19","author":"Engelaere","year":"2018","journal-title":"Korean J Radiol"},{"issue":"8","key":"10.1016\/j.radi.2025.103197_bib26","doi-asserted-by":"crossref","first-page":"3125","DOI":"10.1007\/s00330-017-5157-5","article-title":"European society of urogenital Radiology (ESUR) guidelines: MR imaging of leiomyomas","volume":"28","author":"Kubik-Huch","year":"2018","journal-title":"Eur Radiol"},{"issue":"6","key":"10.1016\/j.radi.2025.103197_bib27","doi-asserted-by":"crossref","first-page":"2770","DOI":"10.1007\/s00261-020-02916-6","article-title":"Do antispasmodics or rectal enemas improve image quality on multiparametric prostate MRI? An \u201cEvidence-Based Practice\u201d review of the literature","volume":"46","author":"Brennan","year":"2021","journal-title":"Abdom Radiol (NY)"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425003414?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425003414?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T21:41:17Z","timestamp":1770154877000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817425003414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["S1078817425003414"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2025.103197","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Efficacy of antiperistaltic agents in improving image quality in pelvic magnetic resonance imaging: A systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2025.103197","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Published by Elsevier Ltd on behalf of The College of Radiographers.","name":"copyright","label":"Copyright"}],"article-number":"103197"}}