{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T02:13:43Z","timestamp":1788488023424,"version":"build-2803163510"},"reference-count":24,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100005778","name":"Central University of Technology","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005778","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.radi.2025.103271","type":"journal-article","created":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T23:25:32Z","timestamp":1765409132000},"page":"103271","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Reference levels in radiation doses and image quality metrics in chest\u2212abdomen protocols in a neonatal unit"],"prefix":"10.1016","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-6314-764X","authenticated-orcid":false,"given":"T.","family":"Mpikeleli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Phahlamohlaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Acho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.radi.2025.103271_bib1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.pedneo.2020.10.009","article-title":"Patient X-ray exposure and ALARA in the neonatal intensive care unit: global patterns","volume":"62","author":"Gislason-Lee","year":"2021","journal-title":"Pediatr Neonatol"},{"issue":"Supplement","key":"10.1016\/j.radi.2025.103271_bib2","first-page":"57","article-title":"Radiation dose reduction in a neonatal intensive care unit in computed","volume":"71","author":"Frayre","year":"2012","journal-title":"Radiography"},{"issue":"2","key":"10.1016\/j.radi.2025.103271_bib3","doi-asserted-by":"crossref","first-page":"e66","DOI":"10.1016\/j.radi.2019.10.013","article-title":"A multi institutional comparison of imaging dose and technique protocols for neonatal chest radiography","volume":"26","author":"Gunn","year":"2020","journal-title":"Radiography"},{"issue":"1","key":"10.1016\/j.radi.2025.103271_bib4","doi-asserted-by":"crossref","first-page":"31","DOI":"10.2471\/BLT.08.062554","article-title":"The worldwide incidence of preterm birth: a systematic review of maternal mortality and morbidity","volume":"88","author":"Beck","year":"2010","journal-title":"Bull World Health Organ"},{"issue":"4","key":"10.1016\/j.radi.2025.103271_bib5","doi-asserted-by":"crossref","first-page":"889","DOI":"10.2214\/AJR.18.21030","article-title":"Expanding the concept of diagnostic reference levels to noise and dose reference levels in CT","volume":"213","author":"Ria","year":"2019","journal-title":"Am J Roentgenol"},{"key":"10.1016\/j.radi.2025.103271_bib6","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.clinimag.2022.10.016","article-title":"Oncology-specific radiation dose and image noise reference levels in adult abdominal-pelvic CT","volume":"93","author":"Ahmad","year":"2023","journal-title":"Clin Imag"},{"issue":"11","key":"10.1016\/j.radi.2025.103271_bib7","doi-asserted-by":"crossref","first-page":"7019","DOI":"10.1118\/1.4760886","article-title":"An image-based technique to assess the perceptual quality of clinical chest radiographs","volume":"39","author":"Lin","year":"2012","journal-title":"Med Phys"},{"issue":"4","key":"10.1016\/j.radi.2025.103271_bib8","doi-asserted-by":"crossref","DOI":"10.1109\/TCOM.1983.1095851","article-title":"The Laplacian pyramid as a compact image code","author":"Burt","year":"1983","journal-title":"IEEE Trans Commun"},{"key":"10.1016\/j.radi.2025.103271_bib9","unstructured":"European CommissionGuidelinesEur16261.pdf [Internet]. Available from: https:\/\/www.sprmn.pt\/pdf\/EuropeanGuidelinesEur16261.pdf [accessed Sept 11, 2025]."},{"key":"10.1016\/j.radi.2025.103271_bib10","series-title":"Guidelines on requirements for licence holders with respect to quality control tests for medical diagnostic -ray imaging systems","year":"2022"},{"key":"10.1016\/j.radi.2025.103271_bib11","series-title":"The essential physics of medical imaging","author":"Bushberg","year":"2020"},{"key":"10.1016\/j.radi.2025.103271_bib12","series-title":"Dosimetry in diagnostic radiology: an international code of practice","year":"2007"},{"issue":"958","key":"10.1016\/j.radi.2025.103271_bib13","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1259\/bjr\/77948690","article-title":"Dose and image quality optimization in neonatal radiography","volume":"80","author":"Dougeni","year":"2007","journal-title":"Br J Radiol"},{"issue":"895","key":"10.1016\/j.radi.2025.103271_bib14","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1259\/bjr.75.895.750590","article-title":"Radiation dose quantities and risk in neonates in a special care baby unit","volume":"75","author":"Armpilia","year":"2002","journal-title":"Br J Radiol"},{"issue":"796","key":"10.1016\/j.radi.2025.103271_bib15","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1259\/0007-1285-67-796-366","article-title":"Energy imparted to neonates during X-ray examinations in a special care baby unit","volume":"67","author":"Chapple","year":"1994","journal-title":"Br J Radiol"},{"key":"10.1016\/j.radi.2025.103271_bib16","series-title":"Institute of physical sciences in medicine L (UK). Patient dosimetry techniques in diagnostic radiology","author":"Wall","year":"1988"},{"key":"10.1016\/j.radi.2025.103271_bib17","unstructured":"Solomon JB. imtool3D. MATLAB Help Center. Available from: https:\/\/www.mathworks.com\/matlabcentral\/fileexchange\/40753-imtool3d [accessed August 25, 2025]."},{"issue":"3","key":"10.1016\/j.radi.2025.103271_bib18","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1093\/rpd\/ncx051","article-title":"Excess radiation to newborns hospitalized in the intensive care unit","volume":"177","author":"Komatsu","year":"2017","journal-title":"Radiat Protect Dosim"},{"key":"10.1016\/j.radi.2025.103271_bib19","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.radphyschem.2013.11.035","article-title":"Evaluation of radiation dose to neonates in a special care baby unit","volume":"104","author":"Alzimami","year":"2014","journal-title":"Radiat Phys Chem"},{"issue":"2","key":"10.1016\/j.radi.2025.103271_bib20","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/s11604-021-01193-7","article-title":"Chest X-rays of newborns in a medical facility: variation between the entrance skin dose measurements using the indirect and direct methods for clinical dose audit","volume":"40","author":"Omojola","year":"2022","journal-title":"Jpn J Radiol"},{"issue":"1","key":"10.1016\/j.radi.2025.103271_bib21","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1093\/rpd\/nct184","article-title":"Radiation dose to premature new-borns in the Belgian neonatal intensive care units","volume":"158","author":"Dabin","year":"2014","journal-title":"Radiat Protect Dosim"},{"issue":"2","key":"10.1016\/j.radi.2025.103271_bib22","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/j.1651-2227.2008.01087.x","article-title":"Exposure of extremely low birth weight infants to diagnostic X-Rays: a longitudinal study","volume":"98","author":"Arad","year":"2009","journal-title":"Acta Paediatr"},{"key":"10.1016\/j.radi.2025.103271_bib23","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1590\/S0100-39842008000500011","article-title":"Risks of radiographic procedures for neonates admitted to a public hospital in Belo Horizonte, MG, Brazil","volume":"41","author":"Lacerda","year":"2008","journal-title":"Radiol Bras"},{"key":"10.1016\/j.radi.2025.103271_bib24","series-title":"Doses to patients from medical X-ray examinations in the UK. 2000 review","author":"Hart","year":"2002"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425004158?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817425004158?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T01:45:12Z","timestamp":1788486312000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817425004158"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["S1078817425004158"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2025.103271","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Reference levels in radiation doses and image quality metrics in chest\u2212abdomen protocols in a neonatal unit","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2025.103271","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Published by Elsevier Ltd on behalf of The College of Radiographers.","name":"copyright","label":"Copyright"}],"article-number":"103271"}}