{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T03:12:36Z","timestamp":1788491556279,"version":"build-2803163510"},"reference-count":19,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T00:00:00Z","timestamp":1783728000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.radi.2026.103489","type":"journal-article","created":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T08:47:34Z","timestamp":1784710054000},"page":"103489","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of a silver filter with deep learning reconstruction on noncontrast abdominopelvic MDCT in terms of image quality, density values and radiation dose reduction"],"prefix":"10.1016","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0527-5305","authenticated-orcid":false,"given":"C.","family":"Roy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Kledy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Mertz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"Jaillet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Q.","family":"le Duff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Labani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Moli\u00e9re","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Ohana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.radi.2026.103489_bib1","doi-asserted-by":"crossref","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","article-title":"Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer","volume":"169","author":"Smith-Bindman","year":"2009","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.radi.2026.103489_bib2","doi-asserted-by":"crossref","DOI":"10.3389\/fpubh.2022.1094328","article-title":"Estimation of radiation doses and lifetime attributable risk of radiation-induced cancer in the uterus and prostate from abdomen pelvis CT examinations","volume":"10","author":"Shubayr","year":"2023","journal-title":"Front Public Health"},{"key":"10.1016\/j.radi.2026.103489_bib3","doi-asserted-by":"crossref","DOI":"10.1136\/bmj.f2360","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ"},{"key":"10.1016\/j.radi.2026.103489_bib4","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.2015132766","article-title":"State of the art: iterative CT reconstruction techniques","volume":"276","author":"Geyer","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.radi.2026.103489_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2019.108703","article-title":"Assessment of image quality in abdominal computed tomography: effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction","volume":"122","author":"Kataria","year":"2020","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib6","first-page":"107","article-title":"Prospective evaluation of ultra-low-dose contrast-enhanced 100-kV abdominal computed tomography with tin filter: effect on radiation dose reduction and image quality with a third-generation dual-source CT system","volume":"292","author":"Leyendecker","year":"2019","journal-title":"Eur Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib7","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1055\/a-1248-2556","article-title":"Deep learning CT image reconstruction in clinical practice","volume":"193","author":"Arndt","year":"2021","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"10.1016\/j.radi.2026.103489_bib8","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.crad.2021.01.010","article-title":"The future of CT: deep learning reconstruction","volume":"76","author":"McLeavy","year":"2021","journal-title":"Clin Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib9","doi-asserted-by":"crossref","first-page":"2921","DOI":"10.1007\/s00330-021-08438-z","article-title":"The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis","volume":"32","author":"Van Stiphout","year":"2022","journal-title":"Eur Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib10","doi-asserted-by":"crossref","first-page":"5613","DOI":"10.1007\/s00330-024-10649-z","article-title":"Ultra-low dose chest CT with silver filter and deep learning reconstruction significantly reduces radiation dose and retains quantitative information in the investigation and monitoring of lymphangioleiomyomatosis (LAM)","volume":"34","author":"Golbus","year":"2024","journal-title":"Eur Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib11","doi-asserted-by":"crossref","first-page":"74","DOI":"10.15406\/jcpcr.2023.14.00524","article-title":"Impact of silver beam on radiation dose reduction in chest computed tomography: first impressions","volume":"14","author":"Cirino","year":"2023","journal-title":"J Cancer Prev Curr Res"},{"key":"10.1016\/j.radi.2026.103489_bib12","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1097\/RCT.0000000000001538","article-title":"Usefulness of Ag additional filter on image quality and radiation dose for Low- dose chest computed tomography","volume":"48","author":"Kawamoto","year":"2024","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.radi.2026.103489_bib13","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/RCT.0000000000001026","article-title":"Radiation dose reduction for computed tomography localizer radiography using an Ag additional filter","volume":"45","author":"Nomura","year":"2021","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.radi.2026.103489_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2023.110969","article-title":"Capability for dose reduction while maintaining nodule detection: comparison of silver and copper X-ray spectrum modulation filters for chest CT using a phantom study with different reconstruction methods","volume":"166","author":"Oshima","year":"2023","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.radi.2026.103489_bib15","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-025-11184-7","article-title":"Image quality and radiation dose of reduced-dose abdominopelvic computed tomography (CT) with silver filter and deep learning reconstruction","volume":"15","author":"Otgonbaatar","year":"2025","journal-title":"Sci Rep"},{"key":"10.1016\/j.radi.2026.103489_bib16","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1120\/jacmp.v17i3.5724","article-title":"An evaluation of organ dose modulation on a GE optima CT660-computed tomography scanner","volume":"17","author":"Dixon","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.radi.2026.103489_bib17","first-page":"1","article-title":"The effects of CT x-ray tube voltage and current variations on the relative electron density (RED) and CT number conversion curves","volume":"13","author":"Afifi","year":"2020","journal-title":"J Radiat Res Appl Sci"},{"key":"10.1016\/j.radi.2026.103489_bib18","first-page":"289","article-title":"The influence of different kVs and phantoms on computed tomography number to relative electron density calibration curve for radiotherapy dose calculation Prec","volume":"6","author":"Jaafar","year":"2022","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.radi.2026.103489_bib19","doi-asserted-by":"crossref","first-page":"426","DOI":"10.4103\/jcrt.jcrt_260_21","article-title":"Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: a semi-anthropomorphic thorax phantom study","volume":"19","author":"Sorooshfard","year":"2023","journal-title":"J Cancer Res Therapeut"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817426001653?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817426001653?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T02:18:36Z","timestamp":1788488316000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817426001653"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S1078817426001653"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2026.103489","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Impact of a silver filter with deep learning reconstruction on noncontrast abdominopelvic MDCT in terms of image quality, density values and radiation dose reduction","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2026.103489","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd on behalf of The College of Radiographers.","name":"copyright","label":"Copyright"}],"article-number":"103489"}}