{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T03:12:12Z","timestamp":1788491532539,"version":"build-2803163510"},"reference-count":38,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003593","name":"National Council for Scientific and Technological Development","doi-asserted-by":"publisher","award":["133076\/2023-7"],"award-info":[{"award-number":["133076\/2023-7"]}],"id":[{"id":"10.13039\/501100003593","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","radiographyonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Radiography"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.radi.2026.103532","type":"journal-article","created":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T15:50:44Z","timestamp":1786117844000},"page":"103532","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure"],"prefix":"10.1016","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-0337-7745","authenticated-orcid":false,"given":"L.A.O.","family":"da Silva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.D.C.B.","family":"Braga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.R.R.","family":"Cardoso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.H.F.","family":"Jord\u00e3o","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.M.","family":"de Arruda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.O.S. de C.","family":"Meneses","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.S.","family":"Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Fernandes-Ferreira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.radi.2026.103532_bib1","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1007\/s00330-013-2808-z","article-title":"Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight?","volume":"23","author":"Kondo","year":"2013","journal-title":"Eur Radiol julho de"},{"issue":"1","key":"10.1016\/j.radi.2026.103532_bib2","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s41747-018-0074-1","article-title":"Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight","volume":"2","author":"Zanardo","year":"2018","journal-title":"Eur Radiol Exp"},{"key":"10.1016\/j.radi.2026.103532_bib6","article-title":"Implementation of patient-tailored contrast volumes based on body surface area and heart rate harmonizes contrast enhancement and reduces contrast load in small patients in portal venous phase abdominal CT","volume":"121","author":"Walgraeve","year":"2019","journal-title":"Eur J Radiol dezembro de"},{"key":"10.1016\/j.radi.2026.103532_bib7","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.eclinm.2018.07.002","article-title":"Immediate hypersensitivity to contrast agents: the French 5-year CIRTACI Study","volume":"1","author":"Clement","year":"2018","journal-title":"EClinicalMedicine julho de"},{"issue":"5","key":"10.1016\/j.radi.2026.103532_bib8","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1007\/s00261-019-01896-6","article-title":"Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study","volume":"44","author":"You","year":"2019","journal-title":"Abdom Radiol (NY) maio de"},{"issue":"12","key":"10.1016\/j.radi.2026.103532_bib9","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.3390\/jpm11121255","article-title":"Liver enhancement on computed tomography Is suboptimal in patients with liver steatosis","volume":"11","author":"van Cooten","year":"2021","journal-title":"J Pers Med"},{"issue":"8","key":"10.1016\/j.radi.2026.103532_bib10","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1007\/s00330-014-3227-5","article-title":"Determination of optimal intravenous contrast agent iodine dose for the detection of liver metastasis at 80-kVp CT","volume":"24","author":"Goshima","year":"2014","journal-title":"Eur Radiol agosto de"},{"key":"10.1016\/j.radi.2026.103532_bib11","article-title":"Evaluation of the practice of performing abdominal CT Scan with manually administered fixed dose of contrast in achieving adequate hepatic enhancement: an institutional-based cross-sectional Study","volume":"2023","author":"Legesse","year":"2023","journal-title":"Radiol Res Pract"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib12","first-page":"199","article-title":"Iodinated contrast media and the role of renal replacement therapy. Advances in chronic kidney disease","volume":"18","author":"Weisbord","year":"2011","journal-title":"Toxicology for Nephrologists"},{"key":"10.1016\/j.radi.2026.103532_bib13","doi-asserted-by":"crossref","first-page":"50","DOI":"10.25259\/JCIS_153_2024","article-title":"Correlation of patient characteristics with peak enhancement time for pediatric cardiac computed tomography in congenital heart disease","volume":"14","author":"Visakh","year":"2024","journal-title":"J Clin Imaging Sci"},{"issue":"1","key":"10.1016\/j.radi.2026.103532_bib14","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s13244-021-00980-0","article-title":"Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols","volume":"12","author":"Caruso","year":"2021","journal-title":"Insights Imaging"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib15","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jacr.2016.09.001","article-title":"Effect of fixed-volume and weight-based dosing regimens on the cost and volume of administered iodinated contrast material at abdominal CT","volume":"14","author":"Davenport","year":"2017","journal-title":"J Am Coll Radiol mar\u00e7o de"},{"issue":"2","key":"10.1016\/j.radi.2026.103532_bib16","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.carj.2018.08.005","article-title":"Effect of patient characteristics on vessel enhancement in pediatric chest computed tomography angiography","volume":"70","author":"Masuda","year":"2019","journal-title":"Can Assoc Radiol J maio de"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib17","first-page":"773","article-title":"The optimal body size index with Which to determine iodine dose for hepatic dynamic CT: a prospective multicenter Study. Radiology","volume":"278","author":"Awai","year":"2016","journal-title":"mar\u00e7o de"},{"issue":"7","key":"10.1016\/j.radi.2026.103532_bib18","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1177\/0284185118801137","article-title":"Hepatic enhancement differences when dosing iodinated contrast media according to total versus lean body weight","volume":"60","author":"Peet","year":"2019","journal-title":"Acta Radiol julho de"},{"key":"10.1016\/j.radi.2026.103532_bib19","doi-asserted-by":"crossref","DOI":"10.1155\/2020\/5407936","article-title":"Personalization of CM injection protocols in coronary computed tomographic angiography (people CT trial)","volume":"2020","author":"Eijsvoogel","year":"2020","journal-title":"Contrast Media Mol Imaging"},{"key":"10.1016\/j.radi.2026.103532_bib20","article-title":"Contrast media dose adjustment to allometric parameters of body mass in multiphasic CT of the liver: a comparison of different metrics","volume":"141","author":"Janek","year":"2021","journal-title":"Eur J Radiol agosto de"},{"issue":"2","key":"10.1016\/j.radi.2026.103532_bib21","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1007\/s00330-024-11009-7","article-title":"Feasibility of a single-phase portal venous CT protocol using bolus tracking technique and lean body weight-based contrast media dose","volume":"35","author":"Valletta","year":"2025","journal-title":"Eur Radiol fevereiro de"},{"issue":"6","key":"10.1016\/j.radi.2026.103532_bib22","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/j.acra.2019.07.014","article-title":"Dosing iodinated contrast media according to lean versus total body weight at abdominal CT: a stratified randomized controlled trial","volume":"27","author":"Costa","year":"2020","journal-title":"Acad Radiol junho de"},{"issue":"4","key":"10.1016\/j.radi.2026.103532_bib23","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1007\/s11547-024-01944-2","article-title":"Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose","volume":"130","author":"Caruso","year":"2025","journal-title":"Radiol Med abril de"},{"key":"10.1016\/j.radi.2026.103532_bib24","doi-asserted-by":"crossref","first-page":"38","DOI":"10.25259\/JCIS_97_2021","article-title":"Does contrast dose based in lean body weight allow lesser volumes on high BMI patients for CT angiography?","volume":"11","author":"Chandrasekharan","year":"2021","journal-title":"J Clin Imaging Sci"},{"key":"10.1016\/j.radi.2026.103532_bib25","series-title":"Child and teen BMI categories","year":"2024"},{"issue":"5","key":"10.1016\/j.radi.2026.103532_bib26","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1093\/bja\/aer057","article-title":"Estimation of lean body mass in children","volume":"106","author":"Peters","year":"2011","journal-title":"Br J Anaesth maio de"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib28","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1080\/00401706.1964.10490181","article-title":"Multiple comparisons using rank sums","volume":"6","author":"Dunn","year":"1964","journal-title":"Technometrics"},{"key":"10.1016\/j.radi.2026.103532_bib30","first-page":"1","article-title":"A technique for the measurement of attitudes","volume":"140","author":"Likert","year":"1932","journal-title":"Archives of Psychology"},{"key":"10.1016\/j.radi.2026.103532_bib31","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1177\/001316446002000104","article-title":"A coefficient of agreement for nominal scales","volume":"20","author":"Cohen","year":"1960","journal-title":"Educational and Psychological Measurement"},{"key":"10.1016\/j.radi.2026.103532_bib32","series-title":"Fluid management in pediatric patients. Em: Agr\u00f2 FE, organizador. Body fluid management","first-page":"165","author":"S\u00fcmpelmann","year":"2013"},{"issue":"6","key":"10.1016\/j.radi.2026.103532_bib33","doi-asserted-by":"crossref","first-page":"1721","DOI":"10.1007\/s00431-021-03936-0","article-title":"Body composition monitoring in children and adolescents: reproducibility and reference values","volume":"180","author":"Van Eyck","year":"2021","journal-title":"Eur J Pediatr"},{"issue":"1","key":"10.1016\/j.radi.2026.103532_bib34","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1038\/s41430-019-0409-x","article-title":"Body composition reference charts for UK infants and children aged 6 weeks to 5 years based on measurement of total body water by isotope dilution","volume":"74","author":"Wells","year":"2020","journal-title":"Eur J Clin Nutr"},{"issue":"4","key":"10.1016\/j.radi.2026.103532_bib35","doi-asserted-by":"crossref","first-page":"267","DOI":"10.5114\/pedm.2023.133122","article-title":"Pediatric obesity \u2013 time to act as early as possible","volume":"29","author":"Szczyrska","year":"2023","journal-title":"Pediatr Endocrinol Diabetes Metab"},{"issue":"5","key":"10.1016\/j.radi.2026.103532_bib36","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1097\/RCT.0000000000000909","article-title":"Contrast material injection protocol With the dose determined according to lean body weight at hepatic dynamic computed tomography: Comparison Among patients With different body mass indices","volume":"43","author":"Matsumoto","year":"2019","journal-title":"J Comput Assist Tomogr"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib37","doi-asserted-by":"crossref","first-page":"159","DOI":"10.3390\/jpm11030159","article-title":"Towards personalised contrast injection: Artificial-Intelligence-Derived body composition and liver enhancement in computed tomography","volume":"11","author":"de Jong","year":"2021","journal-title":"J Pers Med"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib38","doi-asserted-by":"crossref","first-page":"489","DOI":"10.3348\/kjr.2018.19.3.489","article-title":"Two small intravenous catheters for high-rate contrast medium injection for computed tomography in patients lacking superficial veins to accommodate a large catheter","volume":"19","author":"Son","year":"2018","journal-title":"Korean J Radiol"},{"issue":"3","key":"10.1016\/j.radi.2026.103532_bib39","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1148\/radiol.2492080033","article-title":"Abdominal multidetector CT in patients with varying body fat percentages: estimation of optimal contrast material dose","volume":"249","author":"Kondo","year":"2008","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.radi.2026.103532_bib40","doi-asserted-by":"crossref","first-page":"703","DOI":"10.2214\/AJR.15.14329","article-title":"Nephrotoxic polypharmacy and risk of contrast medium-induced nephropathy in hospitalized patients undergoing contrast-enhanced CT","volume":"205","author":"Ho","year":"2015","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"10.1016\/j.radi.2026.103532_bib41","doi-asserted-by":"crossref","first-page":"748","DOI":"10.2214\/AJR.23.29651","article-title":"Detection of moderate hepatic steatosis on portal venous phase contrast-enhanced CT: evaluation using an automated artificial intelligence tool","volume":"221","author":"Pickhardt","year":"2023","journal-title":"AJR Am J Roentgenol dezembro de"},{"issue":"1","key":"10.1016\/j.radi.2026.103532_bib42","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1186\/s12887-020-02289-1","article-title":"Improving assessment of child growth in a pediatric hospital setting","volume":"20","author":"Gupta","year":"2020","journal-title":"BMC Pediatr"},{"key":"10.1016\/j.radi.2026.103532_bib43","article-title":"Determining body height and weight from thoracic and abdominal CT localizers in pediatric and young adult patients using deep learning","volume":"13","author":"Demircio\u011flu","year":"2023","journal-title":"Sci Rep"}],"container-title":["Radiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817426002087?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078817426002087?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T02:16:35Z","timestamp":1788488195000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078817426002087"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S1078817426002087"],"URL":"https:\/\/doi.org\/10.1016\/j.radi.2026.103532","relation":{},"ISSN":["1078-8174"],"issn-type":[{"value":"1078-8174","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure","name":"articletitle","label":"Article Title"},{"value":"Radiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.radi.2026.103532","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"103532"}}