{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T03:20:15Z","timestamp":1791343215577,"version":"4.3.1"},"reference-count":14,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2005,3,1]],"date-time":"2005-03-01T00:00:00Z","timestamp":1109635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Radiotherapy and Oncology"],"published-print":{"date-parts":[[2005,3]]},"DOI":"10.1016\/j.radonc.2004.12.003","type":"journal-article","created":{"date-parts":[[2004,12,29]],"date-time":"2004-12-29T05:13:36Z","timestamp":1104297216000},"page":"283-291","source":"Crossref","is-referenced-by-count":147,"title":["Quality assurance in radiotherapy: evaluation of errors and incidents recorded over a 10 year period"],"prefix":"10.1016","volume":"74","author":[{"given":"Tai Keung","family":"Yeung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Bortolotto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott","family":"Cosby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Margaret","family":"Hoar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernst","family":"Lederer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.radonc.2004.12.003_bib1","series-title":"Physics for clinical radiotherapy, Booklet No. 2","article-title":"Recommendations for a quality assurance programme in external radiotherapy","author":"Aletti","year":"1995"},{"key":"10.1016\/j.radonc.2004.12.003_bib2","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0167-8140(97)00095-9","article-title":"Detection of systematic errors in external radiotherapy before treatment delivery","volume":"45","author":"Calandrino","year":"1997","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.radonc.2004.12.003_bib3","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0360-3016(98)00341-1","article-title":"In vivo dosimetry during external photon beam radiotherapy","volume":"43","author":"Essers","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.radonc.2004.12.003_bib4","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1118\/1.598373","article-title":"AAPM Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning","volume":"25","author":"Fraass","year":"1998","journal-title":"Med Phys"},{"key":"10.1016\/j.radonc.2004.12.003_bib5","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/0958-3947(91)90124-K","article-title":"Standardization of dosimetry chart checks","volume":"16","author":"Jaeger","year":"1991","journal-title":"Med Dosim"},{"key":"10.1016\/j.radonc.2004.12.003_bib6","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1259\/0007-1285-46-552-1083-b","article-title":"Accuracy in clinical dosimetry","volume":"46","author":"Kartha","year":"1973","journal-title":"Br J Radiol"},{"key":"10.1016\/j.radonc.2004.12.003_bib7","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1016\/0360-3016(87)90331-2","article-title":"Procedural and operator error aspects of radiation accidents in radiotherapy","volume":"13","author":"Karzmark","year":"1987","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.radonc.2004.12.003_bib8","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1118\/1.597316","article-title":"Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40","volume":"21","author":"Kutcher","year":"1994","journal-title":"Med Phys"},{"key":"10.1016\/j.radonc.2004.12.003_bib9","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/S0167-8140(92)80124-2","article-title":"Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: \u2018garbage in, garbage out\u2019","volume":"23","author":"Leunens","year":"1992","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.radonc.2004.12.003_bib10","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/0360-3016(95)02056-X","article-title":"Lessons learned from investigations of therapy misadministration events","volume":"34","author":"Ostrom","year":"1996","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.radonc.2004.12.003_bib11","article-title":"Accuracy in radiotherapy, a survey of some effects of human fallibility","volume":"vol. 1","author":"Sutherland","year":"1980"},{"key":"10.1016\/j.radonc.2004.12.003_bib12","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/0167-8140(95)01549-V","article-title":"Quality assurance in radiotherapy (ESTRO advisory report to the Commission of the European Union for the \u2018Europe Against Cancer Programme\u2019)","volume":"35","author":"Thwaites","year":"1995","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.radonc.2004.12.003_bib13","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/0167-8140(94)90453-7","article-title":"Evaluation of most frequent errors in daily compilation and use of a radiation treatment chart","volume":"32","author":"Valli","year":"1994","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.radonc.2004.12.003_bib14","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/S0167-8140(00)00190-0","article-title":"Quality assurance in radiotherapy by identifying standards and monitoring treatment preparation","volume":"56","author":"Van Esch","year":"2000","journal-title":"Radiother Oncol"}],"container-title":["Radiotherapy and Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167814004005687?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167814004005687?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,30]],"date-time":"2019-01-30T15:20:52Z","timestamp":1548861652000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167814004005687"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,3]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2005,3]]}},"alternative-id":["S0167814004005687"],"URL":"https:\/\/doi.org\/10.1016\/j.radonc.2004.12.003","relation":{},"ISSN":["0167-8140"],"issn-type":[{"value":"0167-8140","type":"print"}],"subject":[],"published":{"date-parts":[[2005,3]]}}}