{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:36:36Z","timestamp":1740148596023,"version":"3.37.3"},"reference-count":10,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T00:00:00Z","timestamp":1576713600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev Bras Ortop"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:title>Resumo<\/jats:title><jats:p>O uso dos dispositivos cefalomedulares tem ganhado popularidade no tratamento das fraturas do f\u00eamur proximal. Apesar das vantagens biomec\u00e2nicas, v\u00e1rias complica\u00e7\u00f5es s\u00e3o descritas, entre as quais a migra\u00e7\u00e3o medial do parafuso cef\u00e1lico \u00e9 pouco conhecida. Os autores apresentam um caso dessa complica\u00e7\u00e3o incomum em um implante de haste longa tratada em dois tempos cir\u00fargicos para a retirada dos implantes e posterior osteoss\u00edntese com placa bloqueada para f\u00eamur proximal, assim como o desfecho at\u00e9 a consolida\u00e7\u00e3o da fratura e resolu\u00e7\u00e3o do caso.<\/jats:p>","DOI":"10.1016\/j.rbo.2017.12.004","type":"journal-article","created":{"date-parts":[[2018,2,14]],"date-time":"2018-02-14T03:40:06Z","timestamp":1518579606000},"page":"121-124","source":"Crossref","is-referenced-by-count":1,"title":["Migra\u00e7\u00e3o intrap\u00e9lvica do parafuso cef\u00e1lico da haste intramedular longa para f\u00eamur proximal: Relato de caso*"],"prefix":"10.1055","volume":"55","author":[{"given":"Elton Luiz Batista","family":"Cavalcante","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Centro M\u00e9dico Hospitalar Vila Velha (CMHVV), Vila Velha, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernando Junqueira","family":"de Faria","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Centro M\u00e9dico Hospitalar Vila Velha (CMHVV), Vila Velha, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rubens Azevedo","family":"Rodrigues","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Hospital Estadual Jayme dos Santos Neves (HEJSN), Serra, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 Eduardo Grandi","family":"Ribeiro Filho","sequence":"additional","affiliation":[{"name":"Departamento de Ortopedia e Traumatologia, Hospital de Vila Velha, Vila Velha, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7247-9864","authenticated-orcid":false,"given":"Saulo Gomes","family":"de Oliveira","sequence":"additional","affiliation":[{"name":"Departamento de Ortopedia e Traumatologia, Hospital de Vila Velha, Vila Velha, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nelson","family":"Elias","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Ortopedia e Traumatologia, Centro M\u00e9dico Hospitalar Vila Velha (CMHVV), Vila Velha, ES, Brasil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2019,12,19]]},"reference":[{"year":"2008","series-title":"Campbell's operative orthopaedics","author":"Campbell","key":"10.1016\/j.rbo.2017.12.004_bib0055"},{"key":"10.1016\/j.rbo.2017.12.004_bib0060","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/1749-799X-5-62","article-title":"Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature","volume":"5","author":"Li","year":"2010","journal-title":"J Orthop Surg Res."},{"issue":"2","key":"10.1016\/j.rbo.2017.12.004_bib0065","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s00402-005-0085-2","article-title":"Sigmoid perforation after medial migration of lag screw in gamma nailing","volume":"126","author":"Tauber","year":"2006","journal-title":"Arch Orthop Trauma Surg."},{"issue":"4","key":"10.1016\/j.rbo.2017.12.004_bib0070","doi-asserted-by":"crossref","DOI":"10.3928\/01477447-20100225-19","article-title":"Intrapelvic migration of a gamma nail lag screw: review of the possible mechanisms","volume":"33","author":"Flint","year":"2010","journal-title":"Orthopedics."},{"issue":"12","key":"10.1016\/j.rbo.2017.12.004_bib0075","doi-asserted-by":"crossref","first-page":"e119","DOI":"10.1097\/BOT.0b013e3181db7f25","article-title":"Intra\u2010abdominal migration of a lag screw in gamma nailing: report of a case","volume":"24","author":"Heineman","year":"2010","journal-title":"J Orthop Trauma."},{"key":"10.1016\/j.rbo.2017.12.004_bib0080","first-page":"519045","article-title":"Intrapelvic migration of the lag screw in intramedullary nailing","volume":"2014","author":"Takasago","year":"2014","journal-title":"Case Rep Orthop."},{"issue":"8","key":"10.1016\/j.rbo.2017.12.004_bib0085","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.injury.2014.04.016","article-title":"Medial migration of lag screw after gamma nailing","volume":"45","author":"Thein","year":"2014","journal-title":"Injury."},{"issue":"2","key":"10.1016\/j.rbo.2017.12.004_bib0090","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1097\/BOT.0b013e3181a4eeb2","article-title":"Medial migration of lag screw with intrapelvic dislocation in gamma nailing \u2013 A unique problem? A report of 2 cases","volume":"24","author":"Lucke","year":"2010","journal-title":"J Orthop Trauma."},{"issue":"6","key":"10.1016\/j.rbo.2017.12.004_bib0095","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.rbo.2015.12.006","article-title":"Medial migration of the intramedullary Gamma 3 nail \u2013 a case report","volume":"51","author":"Pinheiro","year":"2016","journal-title":"Rev Bras Ortop."},{"issue":"2","key":"10.1016\/j.rbo.2017.12.004_bib0100","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s00402-007-0497-2","article-title":"Medial migration of intramedullary hip fixation devices: a biomechanical analysis","volume":"128","author":"Weil","year":"2008","journal-title":"Arch Orthop Trauma Surg."}],"container-title":["Revista Brasileira de Ortopedia"],"original-title":[],"language":"pt","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S010236161730557X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S010236161730557X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1016\/j.rbo.2017.12.004.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T23:59:18Z","timestamp":1693526358000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1016\/j.rbo.2017.12.004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,19]]},"references-count":10,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2020,2,28]]},"published-print":{"date-parts":[[2020,2]]}},"URL":"https:\/\/doi.org\/10.1016\/j.rbo.2017.12.004","relation":{},"ISSN":["0102-3616","1982-4378"],"issn-type":[{"type":"print","value":"0102-3616"},{"type":"electronic","value":"1982-4378"}],"subject":[],"published":{"date-parts":[[2019,12,19]]}}}