{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T12:48:04Z","timestamp":1787748484057,"version":"build-2784847793"},"reference-count":30,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","revespcardiol.org","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)"],"published-print":{"date-parts":[[2016,2]]},"DOI":"10.1016\/j.rec.2015.06.024","type":"journal-article","created":{"date-parts":[[2015,11,4]],"date-time":"2015-11-04T19:08:51Z","timestamp":1446664131000},"page":"141-148","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation"],"prefix":"10.1016","volume":"69","author":[{"given":"Oliver","family":"Husser","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thorsten","family":"Kessler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christof","family":"Burgdorf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Templin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Costanza","family":"Pellegrini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert Markus","family":"Kasel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adnan","family":"Kastrati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heribert","family":"Schunkert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Hengstenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.rec.2015.06.024_bib0155","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1093\/eurheartj\/eht381","article-title":"The German Aortic Valve Registry (GARY): in-hospital outcome","volume":"35","author":"Hamm","year":"2014","journal-title":"Eur Heart J."},{"key":"10.1016\/j.rec.2015.06.024_bib0160","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1056\/NEJMoa1114705","article-title":"Registry of transcatheter aortic-valve implantation in high-risk patients","volume":"366","author":"Gilard","year":"2012","journal-title":"N Engl J Med."},{"key":"10.1016\/j.rec.2015.06.024_bib0165","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N Engl J Med."},{"key":"10.1016\/j.rec.2015.06.024_bib0170","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter vs surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med."},{"key":"10.1016\/j.rec.2015.06.024_bib0175","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.amjcard.2013.04.026","article-title":"Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve vs the Edwards valve","volume":"112","author":"Franzoni","year":"2013","journal-title":"Am J Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0180","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1016\/j.jacc.2012.07.035","article-title":"Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve","volume":"60","author":"Urena","year":"2012","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0185","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.4244\/EIJV9I10A194","article-title":"Occurrence, fate and consequences of ventricular conduction abnormalities after transcatheter aortic valve implantation","volume":"9","author":"Houthuizen","year":"2014","journal-title":"EuroIntervention."},{"key":"10.1016\/j.rec.2015.06.024_bib0190","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1093\/eurheartj\/eht376","article-title":"Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience","volume":"35","author":"Nazif","year":"2013","journal-title":"Eur Heart J."},{"key":"10.1016\/j.rec.2015.06.024_bib0195","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jcin.2013.08.015","article-title":"Impact of new-onset persistent left bundle branch block on late clinical outcomes in patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve","volume":"7","author":"Urena","year":"2014","journal-title":"JACC Cardiovasc Interv."},{"key":"10.1016\/j.rec.2015.06.024_bib0200","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.jcin.2012.08.011","article-title":"Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function","volume":"5","author":"Hoffmann","year":"2012","journal-title":"JACC Cardiovasc Interv."},{"key":"10.1016\/j.rec.2015.06.024_bib0205","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.amjcard.2010.09.015","article-title":"Frequency of conduction abnormalities after transcatheter aortic valve implantation with the Medtronic-CoreValve and the effect on left ventricular ejection fraction","volume":"107","author":"Tzikas","year":"2011","journal-title":"Am J Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0210","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1161\/CIRCULATIONAHA.113.005479","article-title":"Permanent pacemaker implantation following transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function","volume":"129","author":"Urena","year":"2013","journal-title":"Circulation."},{"key":"10.1016\/j.rec.2015.06.024_bib0215","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jcin.2012.09.019","article-title":"Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve","volume":"6","author":"Binder","year":"2013","journal-title":"JACC Cardiovasc Interv."},{"key":"10.1016\/j.rec.2015.06.024_bib0220","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","article-title":"SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR)","volume":"6","author":"Achenbach","year":"2012","journal-title":"J Cardiovasc Comput Tomogr."},{"key":"10.1016\/j.rec.2015.06.024_bib0225","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.jacc.2008.12.013","volume":"53","author":"Surawicz","year":"2009","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0230","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1016\/j.jacc.2012.09.001","article-title":"Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document","volume":"60","author":"Kappetein","year":"2012","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0235","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1093\/eurheartj\/ehq261","article-title":"Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry","volume":"32","author":"Eltchaninoff","year":"2011","journal-title":"Eur Heart J."},{"key":"10.1016\/j.rec.2015.06.024_bib0240","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.amjcard.2010.07.012","article-title":"Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation","volume":"106","author":"Roten","year":"2010","journal-title":"Am J Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0245","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jacc.2014.04.033","article-title":"Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis","volume":"64","author":"Siontis","year":"2014","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0250","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1016\/j.jacc.2009.06.006","article-title":"The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy","volume":"54","author":"Tops","year":"2009","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0255","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.jacc.2012.03.054","article-title":"Impact of permanent pacemaker implantation on clinical outcome among patients undergoing transcatheter aortic valve implantation","volume":"60","author":"Buellesfeld","year":"2012","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0260","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.acvd.2013.01.006","article-title":"Cost of transcatheter aortic valve implantation and factors associated with higher hospital stay cost in patients of the FRANCE (FRench Aortic National CoreValve and Edwards) registry","volume":"106","author":"Chevreul","year":"2013","journal-title":"Arch Cardiovasc Dis."},{"key":"10.1016\/j.rec.2015.06.024_bib0265","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/joic.12182","article-title":"First experience with the new generation edwards sapien 3 aortic bioprosthesis: procedural results and short term outcome","volume":"28","author":"Murray","year":"2015","journal-title":"J Interv Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0270","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1016\/j.jacc.2014.09.026","article-title":"Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve","volume":"64","author":"Webb","year":"2014","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0275","article-title":"Unravelling the (arte)fact of increased pacemaker rate with the Edwards SAPIEN 3 valve","author":"Tarantini","year":"2014","journal-title":"EuroIntervention."},{"key":"10.1016\/j.rec.2015.06.024_bib0280","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jacc.2011.05.007","article-title":"Transcatheter valve therapy a professional society overview from the american college of cardiology foundation and the society of thoracic surgeons","volume":"58","author":"Holmes","year":"2011","journal-title":"J Am Coll Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0285","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.ijcard.2012.11.115","article-title":"Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System","volume":"168","author":"van der Boon","year":"2013","journal-title":"Int J Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0290","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1093\/eurheartj\/ehr110","article-title":"Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis","volume":"32","author":"Nuis","year":"2011","journal-title":"Eur Heart J."},{"key":"10.1016\/j.rec.2015.06.024_bib0295","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ijcard.2011.03.004","article-title":"Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation","volume":"160","author":"Aktug","year":"2012","journal-title":"Int J Cardiol."},{"key":"10.1016\/j.rec.2015.06.024_bib0300","doi-asserted-by":"crossref","first-page":"E144","DOI":"10.1002\/ccd.25765","article-title":"Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation","volume":"85","author":"van der Boon","year":"2015","journal-title":"Catheter Cardiovasc Interv."}],"container-title":["Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1885585715003400?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1885585715003400?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,18]],"date-time":"2018-09-18T01:58:27Z","timestamp":1537235907000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1885585715003400"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,2]]}},"alternative-id":["S1885585715003400"],"URL":"https:\/\/doi.org\/10.1016\/j.rec.2015.06.024","relation":{},"ISSN":["1885-5857"],"issn-type":[{"value":"1885-5857","type":"print"}],"subject":[],"published":{"date-parts":[[2016,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation","name":"articletitle","label":"Article Title"},{"value":"Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.rec.2015.06.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.recesp.2015.06.027","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Sociedad Espa\u00f1ola de Cardiolog\u00eda. Published by Elsevier Espa\u00f1a, S.L. All rights reserved.","name":"copyright","label":"Copyright"}]}}