{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T16:59:55Z","timestamp":1789837195246,"version":"4.0.1"},"reference-count":55,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T00:00:00Z","timestamp":1491004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","revespcardiol.org","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1016\/j.rec.2017.01.012","type":"journal-article","created":{"date-parts":[[2017,2,8]],"date-time":"2017-02-08T22:16:18Z","timestamp":1486592178000},"page":"282-291","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"title":["Three-dimensional Printed Cardiac Models: Applications in the Field of Medical Education, Cardiovascular Surgery, and Structural Heart Interventions"],"prefix":"10.1016","volume":"70","author":[{"given":"Israel","family":"Valverde","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.rec.2017.01.012_bib0280","doi-asserted-by":"crossref","first-page":"e608","DOI":"10.1161\/CIRCULATIONAHA.115.020735","article-title":"Three-dimensional printing as an aid in transcatheter closure of secundum atrial septal defect with rim deficiency: in vitro trial occlusion based on a personalized heart model","volume":"133","author":"Chaowu","year":"2016","journal-title":"Circulation."},{"key":"10.1016\/j.rec.2017.01.012_bib0285","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1093\/icvts\/ivv320","article-title":"Three-dimensional printed prototypes refine the anatomy of post-modified Norwood-1 complex aortic arch obstruction and allow presurgical simulation of the repair","volume":"22","author":"Kiraly","year":"2016","journal-title":"Interact Cardiovasc Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0290","doi-asserted-by":"crossref","DOI":"10.1016\/j.jtcvs.2014.12.059","article-title":"Three-dimensional printing to facilitate anatomic study, device development, simulation, and planning in thoracic surgery","volume":"149","author":"Kurenov","year":"2015","journal-title":"J Thorac Cardiovasc Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0295","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.jcmg.2014.04.030","article-title":"A novel approach to neonatal management of tetralogy of fallot, with pulmonary atresia, and multiple aortopulmonary collaterals","volume":"8","author":"Ryan","year":"2015","journal-title":"JACC Cardiovasc Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0300","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1161\/CIRCULATIONAHA.115.015842","article-title":"Myocardial 3-dimensional printing for septal myectomy guidance in a patient with obstructive hypertrophic cardiomyopathy","volume":"132","author":"Yang","year":"2015","journal-title":"Circulation."},{"key":"10.1016\/j.rec.2017.01.012_bib0305","doi-asserted-by":"crossref","first-page":"e31","DOI":"10.1016\/j.athoracsur.2011.09.031","article-title":"Three-dimensional printing of models for preoperative planning and simulation of transcatheter valve replacement","volume":"93","author":"Schmauss","year":"2012","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0310","doi-asserted-by":"crossref","first-page":"e297","DOI":"10.1016\/j.ijcard.2013.12.192","article-title":"3D heart model guides complex stent angioplasty of pulmonary venous baffle obstruction in a Mustard repair of D-TGA","volume":"172","author":"Olivieri","year":"2014","journal-title":"Int J Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0315","first-page":"302","article-title":"Simulative operation on congenital heart disease using rubber-like urethane stereolithographic biomodels based on 3D datasets of multislice computed tomography","volume":"37","author":"Shiraishi","year":"2010","journal-title":"Eur J Cardiothorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0320","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1177\/2150135115610285","article-title":"Use of a three-dimensional printed cardiac model to assess suitability for biventricular repair","volume":"7","author":"Farooqi","year":"2016","journal-title":"World J Pediatr Congenit Heart Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0325","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1002\/ccd.25810","article-title":"3D printed models for planning endovascular stenting in transverse aortic arch hypoplasia","volume":"85","author":"Valverde","year":"2015","journal-title":"Catheter Cardiovasc Interv."},{"key":"10.1016\/j.rec.2017.01.012_bib0330","doi-asserted-by":"crossref","first-page":"e007165","DOI":"10.1136\/bmjopen-2014-007165","article-title":"3D-manufactured patient-specific models of congenital heart defects for communication in clinical practice: feasibility and acceptability","volume":"5","author":"Biglino","year":"2015","journal-title":"BMJ Open."},{"key":"10.1016\/j.rec.2017.01.012_bib0335","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1017\/S1047951114000742","article-title":"Three-dimensional patient-specific cardiac model for surgical planning in Nikaidoh procedure","volume":"25","author":"Valverde","year":"2015","journal-title":"Cardiol Young."},{"key":"10.1016\/j.rec.2017.01.012_bib0340","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.athoracsur.2007.06.001","article-title":"Physical models aiding in complex congenital heart surgery","volume":"86","author":"Mottl-Link","year":"2008","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0345","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1016\/j.athoracsur.2006.12.004","article-title":"Stereolithographic models for surgical planning in congenital heart surgery","volume":"83","author":"Sodian","year":"2007","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0350","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1148\/radiol.2422051994","article-title":"Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data","volume":"242","author":"Schievano","year":"2007","journal-title":"Radiology."},{"key":"10.1016\/j.rec.2017.01.012_bib0355","doi-asserted-by":"crossref","DOI":"10.1007\/s10278-016-9879-8","article-title":"Integration of computed tomography and three-dimensional echocardiography for hybrid three-dimensional printing in congenital heart disease","author":"Gosnell","year":"2016","journal-title":"J Digit Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0360","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.acvd.2015.09.004","article-title":"Advances in 3D echocardiography: From foetus to printing","volume":"109","author":"Acar","year":"2016","journal-title":"Arch Cardiovasc Dis."},{"key":"10.1016\/j.rec.2017.01.012_bib0365","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/s10554-015-0801-0","article-title":"Three dimensional printing of an atrial septal defect: Is it multimodality imaging?","volume":"32","author":"Faganello","year":"2016","journal-title":"Int J Cardiovasc Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0370","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.echo.2015.02.005","article-title":"Echocardiography and three-dimensional printing: Sound ideas to touch a heart","volume":"28","author":"Farooqi","year":"2015","journal-title":"J Am Soc Echocardiogr."},{"key":"10.1016\/j.rec.2017.01.012_bib0375","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.echo.2014.12.016","article-title":"Three-dimensional printing of intracardiac defects from three-dimensional echocardiographic images: Feasibility and relative accuracy","volume":"28","author":"Olivieri","year":"2015","journal-title":"J Am Soc Echocardiogr."},{"key":"10.1016\/j.rec.2017.01.012_bib0380","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s10278-014-9761-5","article-title":"Ultrasound-derived three-dimensional printing in congenital heart disease","volume":"28","author":"Samuel","year":"2014","journal-title":"J Digit Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0385","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1007\/s00246-016-1385-8","article-title":"Blood pool segmentation results in superior virtual cardiac models than myocardial segmentation for 3D printing","volume":"37","author":"Farooqi","year":"2016","journal-title":"Pediatr Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0390","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","article-title":"User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability","volume":"31","author":"Yushkevich","year":"2006","journal-title":"Neuroimage."},{"key":"10.1016\/j.rec.2017.01.012_bib0395","first-page":"669","article-title":"New technologies applied to surgical processes: Virtual reality and rapid prototyping","volume":"210","author":"Su\u00e1rez-Mej\u00edas","year":"2015","journal-title":"Stud Heal Technol Inf."},{"key":"10.1016\/j.rec.2017.01.012_bib0400","first-page":"1","article-title":"A systematic review of image segmentation methodology, used in the additive manufacture of patient-specific 3D printed models of the cardiovascular system","volume":"5","author":"Byrne","year":"2016","journal-title":"JRSM Cardiovasc Dis."},{"key":"10.1016\/j.rec.2017.01.012_bib0405","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.copbio.2011.02.006","article-title":"Organ printing: from bioprinter to organ biofabrication line","volume":"22","author":"Mironov","year":"2011","journal-title":"Curr Opin Biotechnol."},{"key":"10.1016\/j.rec.2017.01.012_bib0410","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1097\/SLA.0b013e318243a4db","article-title":"Regenerative medicine as applied to general surgery","volume":"255","author":"Orlando","year":"2012","journal-title":"Ann Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0415","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1016\/j.surg.2015.12.017","article-title":"Advantages and disadvantages of 3-dimensional printing in surgery: A systematic review","volume":"159","author":"Martelli","year":"2016","journal-title":"Surgery."},{"key":"10.1016\/j.rec.2017.01.012_bib0420","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1007\/s40124-016-0099-y","article-title":"Novel uses for three-dimensional printing in congenital heart disease","volume":"4","author":"Loke","year":"2016","journal-title":"Curr Pediatr Rep."},{"key":"10.1016\/j.rec.2017.01.012_bib0425","unstructured":"U.S. Department of Health and Human Services \u2014 National Institutes of Health. NIH 3D Print Exchange [accessed 2016 Sept 27]. http:\/\/3dprint.nih.gov\/collections\/heart-library."},{"key":"10.1016\/j.rec.2017.01.012_bib0430","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/01.RVI.0000197480.16245.1A","article-title":"Simulation devices in interventional radiology: validation pending","volume":"17","author":"Gould","year":"2006","journal-title":"J Vasc Interv Radiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0435","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1002\/ccd.25048","article-title":"The current state of medical simulation in interventional cardiology: A clinical document from the Society for Cardiovascular Angiography and Intervention's (SCAI) Simulation Committee","volume":"83","author":"Green","year":"2014","journal-title":"Catheter Cardiovasc Interv."},{"key":"10.1016\/j.rec.2017.01.012_bib0440","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/j.jtcvs.2009.03.011","article-title":"The practical clinical value of three-dimensional models of complex congenitally malformed hearts","volume":"138","author":"Riesenkampff","year":"2009","journal-title":"J Thorac Cardiovasc Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0445","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.jtcvs.2008.03.055","article-title":"Pediatric cardiac transplantation: Three-dimensional printing of anatomic models for surgical planning of heart transplantation in patients with univentricular heart","volume":"136","author":"Sodian","year":"2008","journal-title":"J Thorac Cardiovasc Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0450","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1093\/ejcts\/ezu310","article-title":"Three-dimensional printing in cardiac surgery and interventional cardiology: a single-centre experience","volume":"47","author":"Schmauss","year":"2015","journal-title":"Eur J Cardiothorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0455","doi-asserted-by":"crossref","first-page":"2160","DOI":"10.1016\/j.athoracsur.2014.02.011","article-title":"Three-dimensional printing for perioperative planning of complex aortic arch surgery","volume":"97","author":"Schmauss","year":"2014","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0460","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.1016\/j.athoracsur.2007.12.033","article-title":"Three-dimensional printing creates models for surgical planning of aortic valve replacement after previous coronary bypass grafting","volume":"85","author":"Sodian","year":"2008","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0465","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.ijcard.2015.06.015","article-title":"Effect of personalized external aortic root support on aortic root motion and distension in Marfan syndrome patients","volume":"197","author":"Izgi","year":"2015","journal-title":"Int J Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0470","doi-asserted-by":"crossref","first-page":"343","DOI":"10.2217\/ica.15.25","article-title":"Potential of 3D-printed models in planning structural interventional procedures","volume":"7","author":"Gomez-Ciriza","year":"2015","journal-title":"Interv Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0475","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.recesp.2016.04.016","article-title":"Imaging techniques in percutaneous cardiac structural interventions: atrial septal defect closure and left atrial appendage occlusion","volume":"69","author":"Rodr\u00edguez Fern\u00e1ndez","year":"2016","journal-title":"Rev Esp Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0480","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.tcm.2008.11.001","article-title":"Use of rapid prototyping in the care of patients with structural heart disease","volume":"18","author":"Kim","year":"2008","journal-title":"Trends Cardiovasc Med."},{"key":"10.1016\/j.rec.2017.01.012_bib0485","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1093\/ehjci\/jew119","article-title":"Three-dimensional printing for quality management in device closure of interatrial communications","volume":"17","author":"Bartel","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0490","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.ihj.2015.09.021","article-title":"Postinfarct VSD management using 3D computer printing assisted percutaneous closure","volume":"67","author":"Lazkani","year":"2015","journal-title":"Indian Heart J."},{"key":"10.1016\/j.rec.2017.01.012_bib0495","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.recesp.2015.08.003","article-title":"Percutaneous transcatheter mitral valve replacement: heart model and prototyping","volume":"68","author":"Vaquerizo","year":"2015","journal-title":"Rev Esp Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0500","doi-asserted-by":"crossref","first-page":"546","DOI":"10.5603\/KP.2014.0119","article-title":"3D heart model printing for preparation of percutaneous structural interventions: Description of the technology and case report","volume":"72","author":"Dankowski","year":"2014","journal-title":"Kardiol Pol."},{"key":"10.1016\/j.rec.2017.01.012_bib0505","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1002\/ccd.26315","article-title":"Development of a novel hybrid strategy for transcatheter pulmonary valve placement in patients following transannular patch repair of tetralogy of Fallot","volume":"87","author":"Phillips","year":"2016","journal-title":"Catheter Cardiovasc Interv."},{"key":"10.1016\/j.rec.2017.01.012_bib0510","doi-asserted-by":"crossref","first-page":"e151","DOI":"10.1016\/j.jcin.2014.03.015","article-title":"Percutaneous pulmonary valve implantation in a native outflow tract: 3-dimensional DynaCT rotational angiographic reconstruction and 3-dimensional printed model","volume":"7","author":"Poterucha","year":"2014","journal-title":"JACC Cardiovasc Interv."},{"key":"10.1016\/j.rec.2017.01.012_bib0515","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.recesp.2015.10.024","article-title":"Coartaci\u00f3n del quinto arco a\u00f3rtico persistente con interrupci\u00f3n del cuarto arco: primer caso pedi\u00e1trico tratado con stent","volume":"69","author":"Valderrama","year":"2016","journal-title":"Rev Esp Cardiol."},{"key":"10.1016\/j.rec.2017.01.012_bib0520","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.athoracsur.2009.03.014","article-title":"3-dimensional printing of models to create custom-made devices for coil embolization of an anastomotic leak after aortic arch replacement","volume":"88","author":"Sodian","year":"2009","journal-title":"Ann Thorac Surg."},{"key":"10.1016\/j.rec.2017.01.012_bib0525","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.jcct.2015.12.004","article-title":"3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement","volume":"10","author":"Ripley","year":"2016","journal-title":"J Cardiovasc Comput Tomogr."},{"key":"10.1016\/j.rec.2017.01.012_bib0530","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/j.jcmg.2015.03.009","article-title":"The role of 3D printing in structural heart disease: all that glitters is not gold","volume":"8","author":"Mathur","year":"2015","journal-title":"JACC Cardiovasc Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0535","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41205-015-0003-3","article-title":"The residual STL volume as a metric to evaluate accuracy and reproducibility of anatomic models for 3D printing: application in the validation of 3D-printable models of maxillofacial bone from reduced radiation dose CT images","volume":"1","author":"Cai","year":"2015","journal-title":"3D Print Med."},{"key":"10.1016\/j.rec.2017.01.012_bib0540","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1007\/s10278-015-9803-7","article-title":"Factors affecting dimensional accuracy of 3D-printed anatomical structures derived from CT data","volume":"28","author":"Ogden","year":"2015","journal-title":"J Digit Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0545","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s13244-010-0028-5","article-title":"Reconstruction of fetal and infant anatomy using rapid prototyping of post-mortem MR images","volume":"1","author":"Schievano","year":"2010","journal-title":"Insights Imaging."},{"key":"10.1016\/j.rec.2017.01.012_bib0550","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jclinane.2010.02.003","article-title":"What does one minute of operating room time cost?","volume":"22","author":"Macario","year":"2010","journal-title":"J Clin Anesth."}],"container-title":["Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1885585717300440?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1885585717300440?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,4]],"date-time":"2018-09-04T08:51:10Z","timestamp":1536051070000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1885585717300440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":55,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["S1885585717300440"],"URL":"https:\/\/doi.org\/10.1016\/j.rec.2017.01.012","relation":{},"ISSN":["1885-5857"],"issn-type":[{"value":"1885-5857","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Three-dimensional Printed Cardiac Models: Applications in the Field of Medical Education, Cardiovascular Surgery, and Structural Heart Interventions","name":"articletitle","label":"Article Title"},{"value":"Revista Espa\u00f1ola de Cardiolog\u00eda (English Edition)","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.rec.2017.01.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.recesp.2016.09.043","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Sociedad Espa\u00f1ola de Cardiolog\u00eda. Published by Elsevier Espa\u00f1a, S.L.U. All rights reserved.","name":"copyright","label":"Copyright"}]}}