{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T13:26:15Z","timestamp":1793885175734,"version":"4.8.0"},"reference-count":34,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Revista Espa\u00f1ola de Anestesiolog\u00eda y Reanimaci\u00f3n (English Edition)"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.redare.2026.502209","type":"journal-article","created":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T16:07:29Z","timestamp":1792685249000},"page":"502209","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["PROtective ventilation with FLOW\u2013controlled ventilation in ROBOT\u2013assisted laparoscopic surgery (PROFLOW\u2013ROBOTic pilot) \u2013\u2013 study protocol for an international multicenter pilot randomized clinical trial"],"prefix":"10.1016","author":[{"given":"T.","family":"Yurttas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Battaglini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Becker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Dorland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.G.","family":"de Abreu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Gasteiger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.G.","family":"Gil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.N.T.","family":"Hemmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Laffey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Mazzinari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.M.","family":"van Meenen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Moll","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.S.","family":"Neto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Reiter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.M.","family":"Rocco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.R.","family":"Garcia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.G.","family":"Santos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Scharffenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.J.","family":"Schultz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.S.","family":"Slutsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Wittenstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.M.","family":"Luedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.redare.2026.502209_bib0005","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1097\/ALN.0000000000000754","article-title":"Intraoperative protective mechanical ventilation for prevention of postoperative pulmonary complications: a comprehensive review of the role of tidal volume, positive end-expiratory pressure, and lung recruitment maneuvers","volume":"123","author":"G\u00fcldner","year":"2015","journal-title":"Anesthesiology"},{"key":"10.1016\/j.redare.2026.502209_bib0010","first-page":"726","article-title":"Protective lung ventilation in operating room: a systematic review","volume":"80","author":"Futier","year":"2014","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0015","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/j.bja.2020.08.058","article-title":"Ventilation and outcomes following robotic-assisted abdominal surgery: an international, multicentre observational study","volume":"126","year":"2021","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.redare.2026.502209_bib0020","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1097\/EJA.0000000000000646","article-title":"Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - an observational study in 29 countries","volume":"34","year":"2017","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0025","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1016\/S2213-2600(14)70228-0","article-title":"Incidence of mortality and morbidity related to postoperative lung injury in patients who have undergone abdominal or thoracic surgery: a systematic review and meta-analysis","volume":"2","author":"Serpa Neto","year":"2014","journal-title":"Lancet Respir Med"},{"key":"10.1016\/j.redare.2026.502209_bib0030","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1001\/jama.2020.12866","article-title":"Effect of Intraoperative Low Tidal Volume vs Conventional Tidal Volume on Postoperative Pulmonary Complications in Patients Undergoing Major Surgery: A Randomized Clinical Trial","volume":"324","author":"Karalapillai","year":"2020","journal-title":"JAMA"},{"key":"10.1016\/j.redare.2026.502209_bib0035","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1016\/j.bja.2022.02.039","article-title":"Intraoperative positive end-expiratory pressure and postoperative pulmonary complications: a patient-level meta-analysis of three randomised clinical trials","volume":"128","author":"Campos","year":"2022","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.redare.2026.502209_bib0040","doi-asserted-by":"crossref","first-page":"2292","DOI":"10.1001\/jama.2019.7505","article-title":"Effect of Intraoperative High Positive End-Expiratory Pressure (PEEP) With Recruitment Maneuvers vs Low PEEP on Postoperative Pulmonary Complications in Obese Patients: A Randomized Clinical Trial","volume":"321","year":"2019","journal-title":"JAMA"},{"key":"10.1016\/j.redare.2026.502209_bib0045","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0140-6736(14)60416-5","article-title":"High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicentre randomised controlled trial","volume":"384","year":"2014","journal-title":"Lancet"},{"key":"10.1016\/j.redare.2026.502209_bib0050","doi-asserted-by":"crossref","DOI":"10.1016\/S2213-2600(25)00040-2","article-title":"Perioperative lung expansion and pulmonary outcomes after open abdominal surgery versus usual care in the USA (PRIME-AIR): a multicentre, randomised, controlled, phase 3 trial","author":"Fernandez-Bustamante","year":"2025","journal-title":"The Lancet Respir Med"},{"key":"10.1016\/j.redare.2026.502209_bib0055","first-page":"5","article-title":"Ventilation for low dissipated energy achieved using flow control during both inspiration and expiration","volume":"24","author":"Barnes","year":"2019","journal-title":"Trends Anaesth Crit Care"},{"key":"10.1016\/j.redare.2026.502209_bib0060","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/s44158-022-00066-3","article-title":"A new perspective during laryngo-tracheal surgery: the use of an ultra-thin endotracheal tube (Tritube\u00ae) and flow-controlled ventilation-a retrospective case series and a review of the literature","volume":"2","author":"Grassetto","year":"2022","journal-title":"J Anesth Analg Crit Care"},{"key":"10.1016\/j.redare.2026.502209_bib0065","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1093\/bja\/aeu058","article-title":"Flow-controlled expiration: a novel ventilation mode to attenuate experimental porcine lung injury","volume":"113","author":"Goebel","year":"2014","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.redare.2026.502209_bib0070","first-page":"24","article-title":"Individualized flow-controlled ventilation compared to best clinical practice pressure-controlled ventilation: a prospective randomized porcine study","author":"Spraider","year":"2020","journal-title":"Crit Care"},{"key":"10.1016\/j.redare.2026.502209_bib0075","first-page":"8","article-title":"Comparative effects of flow vs. volume-controlled one-lung ventilation on gas exchange and respiratory system mechanics in pigs","author":"Wittenstein","year":"2020","journal-title":"Intensive Care Med Exp"},{"key":"10.1016\/j.redare.2026.502209_bib0080","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/EJA.0000000000000967","article-title":"Flow-controlled ventilation during ear, nose and throat surgery: A prospective observational study","volume":"36","author":"Schmidt","year":"2019","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0085","doi-asserted-by":"crossref","DOI":"10.1016\/j.jclinane.2023.111279","article-title":"Flow-controlled versus pressure-controlled ventilation in cardiac surgery with cardiopulmonary bypass - A single-center, prospective, randomized, controlled trial","volume":"91","author":"Spraider","year":"2023","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.redare.2026.502209_bib0090","doi-asserted-by":"crossref","DOI":"10.1186\/s40635-020-00360-w","article-title":"Flow-controlled ventilation during EVLP improves oxygenation and preserves alveolar recruitment","volume":"8","author":"Ordies","year":"2020","journal-title":"Intensive Care Med Exp"},{"key":"10.1016\/j.redare.2026.502209_bib0095","article-title":"Enhanced ventilation strategies in bariatric surgery: a case report of flow-controlled ventilation in an extremely obese patient undergoing robot-assisted bariatric surgery","volume":"19","author":"Sohm","year":"2025","journal-title":"A A Pract"},{"key":"10.1016\/j.redare.2026.502209_bib0100","doi-asserted-by":"crossref","DOI":"10.1186\/s12871-020-0944-y","article-title":"Flow-controlled ventilation (FCV) improves regional ventilation in obese patients - a randomized controlled crossover trial","volume":"20","author":"Weber","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0105","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1111\/aas.13526","article-title":"Flow-controlled ventilation improves gas exchange in lung-healthy patients- a randomized interventional cross-over study","volume":"64","author":"Weber","year":"2020","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.redare.2026.502209_bib0110","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1097\/ALN.0b013e3181fc6e0a","article-title":"Prediction of postoperative pulmonary complications in a population-based surgical cohort","volume":"113","author":"Canet","year":"2010","journal-title":"Anesthesiology"},{"key":"10.1016\/j.redare.2026.502209_bib0115","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1186\/s13063-024-08479-x","article-title":"Driving pressure during general anesthesia for minimally invasive abdominal surgery (GENERATOR)-study protocol of a randomized clinical trial","volume":"25","year":"2024","journal-title":"Trials"},{"key":"10.1016\/j.redare.2026.502209_bib0120","author":"Castor"},{"issue":"8","key":"10.1016\/j.redare.2026.502209_bib0125","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1001\/jama.2025.23373","article-title":"Intraoperative driving pressure-guided high PEEP vs standard low PEEP for postoperative pulmonary complications.","volume":"335","author":"Aarts","year":"2026","journal-title":"JAMA"},{"key":"10.1016\/j.redare.2026.502209_bib0130","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1164\/rccm.202303-0558WS","article-title":"A new global definition of acute respiratory distress syndrome","volume":"209","author":"Matthay","year":"2024","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.redare.2026.502209_bib0135","doi-asserted-by":"crossref","first-page":"964","DOI":"10.23736\/S0375-9393.23.17382-2","article-title":"Postoperative pulmonary complications and mortality after major abdominal surgery. An observational multicenter prospective study","volume":"89","author":"Piccioni","year":"2023","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0145","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1097\/EJA.0000000000001901","article-title":"Individualised positive end-expiratory pressure titrated intra-operatively by electrical impedance tomography optimises pulmonary mechanics and reduces postoperative atelectasis: a randomised controlled trial","volume":"40","author":"Ma","year":"2023","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.redare.2026.502209_bib0150","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/j.bja.2023.08.007","article-title":"Effect of driving pressure-guided positive end-expiratory pressure on postoperative pulmonary complications in patients undergoing laparoscopic or robotic surgery: a randomised controlled trial","volume":"131","author":"Kim","year":"2023","journal-title":"Br J Anaesth"},{"issue":"3","key":"10.1016\/j.redare.2026.502209_bib0155","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1097\/ALN.0000000000005851","article-title":"Individualized flow-controlled versus pressure-controlled ventilation in cardiac surgery: a randomized controlled trial","volume":"144","author":"Becker","year":"2026","journal-title":"Anesthesiology"},{"issue":"5","key":"10.1016\/j.redare.2026.502209_bib0165","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1111\/anae.16537","article-title":"Association of ventilation volumes, pressures and rates with the mechanical power of ventilation in patients without acute respiratory distress syndrome: exploring the impact of rate reduction","volume":"80","author":"Buiteman-Kruizinga","year":"2025","journal-title":"Anaesthesia"},{"key":"10.1016\/j.redare.2026.502209_bib0170","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1164\/rccm.202009-3467OC","article-title":"Ventilatory variables and mechanical power in patients with acute respiratory distress syndrome","volume":"204","author":"Costa","year":"2021","journal-title":"Am J Respir Crit Care Med"},{"issue":"25","key":"10.1016\/j.redare.2026.502209_bib0175","article-title":"Effects of intraoperative higher versus lower positive end-expiratory pressure during one-lung ventilation for thoracic surgery on postoperative pulmonary complications (PROTHOR): a multicentre, international, randomised, controlled, phase 3 trial","volume":"S2213-2600","year":"2025","journal-title":"Lancet Respir Med"},{"key":"10.1016\/j.redare.2026.502209_bib0180","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2025-103888","article-title":"Consensus on the definition, components, timeframe and grading of composite outcome of postoperative pulmonary complication-protocol for an international mixed-method consensus study (PrECiSIOn)","volume":"15","author":"Nasa","year":"2025","journal-title":"BMJ Open"}],"container-title":["Revista Espa\u00f1ola de Anestesiolog\u00eda y Reanimaci\u00f3n (English Edition)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2341192926001964?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2341192926001964?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T12:39:48Z","timestamp":1793882388000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2341192926001964"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":34,"alternative-id":["S2341192926001964"],"URL":"https:\/\/doi.org\/10.1016\/j.redare.2026.502209","relation":{},"ISSN":["2341-1929"],"issn-type":[{"value":"2341-1929","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"PROtective ventilation with FLOW\u2013controlled ventilation in ROBOT\u2013assisted laparoscopic surgery (PROFLOW\u2013ROBOTic pilot) \u2013\u2013 study protocol for an international multicenter pilot randomized clinical trial","name":"articletitle","label":"Article Title"},{"value":"Revista Espa\u00f1ola de Anestesiolog\u00eda y Reanimaci\u00f3n (English Edition)","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.redare.2026.502209","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.redar.2026.502209","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Sociedad Espa\u00f1ola de Anestesiolog\u00eda, Reanimaci\u00f3n y Terap\u00e9utica del Dolor. Published by Elsevier Espa\u00f1a, S.L.U. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"502209"}}