{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T06:44:33Z","timestamp":1761979473002,"version":"build-2065373602"},"reference-count":23,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2014,7,1]],"date-time":"2014-07-01T00:00:00Z","timestamp":1404172800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","respiratoryinvestigation.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Investigation"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1016\/j.resinv.2014.03.002","type":"journal-article","created":{"date-parts":[[2014,4,24]],"date-time":"2014-04-24T08:51:16Z","timestamp":1398329476000},"page":"236-241","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Comparing surrogates of oxygenation and ventilation between airway pressure release ventilation and biphasic airway pressure in a mechanical model of adult respiratory distress syndrome"],"prefix":"10.1016","volume":"52","author":[{"given":"Ehab G.","family":"Daoud","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert L.","family":"Chatburn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.resinv.2014.03.002_bib1","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/00003246-198705000-00002","article-title":"Airway pressure release ventilation","volume":"15","author":"Stock","year":"1987","journal-title":"Crit Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib2","first-page":"452","article-title":"Biphasic positive airway pressure (BIPAP): a new form of augmented ventilation","volume":"38","author":"Baum","year":"1989","journal-title":"Anaesthesist"},{"key":"10.1016\/j.resinv.2014.03.002_bib3","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1586\/ers.10.66","article-title":"Understanding mechanical ventilators","volume":"4","author":"Chatburn","year":"2010","journal-title":"Expert Rev Respir Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib4","doi-asserted-by":"crossref","first-page":"1766","DOI":"10.1007\/s00134-008-1216-3","article-title":"Airway pressure release ventilation and biphasic positive airway pressure: a systemic review of definitional criteria","volume":"34","author":"Rose","year":"2008","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib5","doi-asserted-by":"crossref","first-page":"282","DOI":"10.4187\/respcare.01238","article-title":"Airway pressure release ventilation: what do we know?","volume":"57","author":"Daoud","year":"2012","journal-title":"Respir Care"},{"key":"10.1016\/j.resinv.2014.03.002_bib6","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1186\/cc2919","article-title":"Clinical review: biphasic positive airway pressure and airway pressure release ventilation","volume":"8","author":"Putensen","year":"2004","journal-title":"Crit Care"},{"key":"10.1016\/j.resinv.2014.03.002_bib7","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1097\/TA.0b013e31803c562f","article-title":"Airway pressure release ventilation and biphasic intermittent positive airway pressure ventilation: are they ready for prime time?","volume":"62","author":"Seymor","year":"2007","journal-title":"J Trauma"},{"key":"10.1016\/j.resinv.2014.03.002_bib8","doi-asserted-by":"crossref","first-page":"296","DOI":"10.3109\/tcic.8.6.296.301","article-title":"Airway pressure release ventilation and biphasic positive airway pressure: a 10-year literature review","volume":"8","author":"Calzia","year":"1997","journal-title":"Clin Intensive Care"},{"key":"10.1016\/j.resinv.2014.03.002_bib9","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","article-title":"Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome","volume":"342","year":"2000","journal-title":"N Engl J Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib10","series-title":"Measurements of respiratory mechanics during mechanical ventilation","first-page":"103","volume":"7","author":"Iotti","year":"1999"},{"key":"10.1016\/j.resinv.2014.03.002_bib11","doi-asserted-by":"crossref","first-page":"15s","DOI":"10.1183\/09031936.03.00420303","article-title":"How respiratory system mechanics may help in minimizing ventilator-induced lung injury in ARDS patients","volume":"22","author":"Terragni","year":"2003","journal-title":"Eur Respir J"},{"key":"10.1016\/j.resinv.2014.03.002_bib12","first-page":"1516","article-title":"Auto-PEEP during APRV varies with the ventilator model","volume":"55","author":"Daoud","year":"2010","journal-title":"Respir Care"},{"key":"10.1016\/j.resinv.2014.03.002_bib13","doi-asserted-by":"crossref","first-page":"1742","DOI":"10.1007\/s00134-002-1522-0","article-title":"Influence of different release times on spontaneous breathing pattern during airway pressure release ventilation","volume":"28","author":"Neumann","year":"2002","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib14","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1097\/00003246-199403000-00020","article-title":"Optimal release time during airway pressure release ventilation in neonatal sheep","volume":"22","author":"Martin","year":"1994","journal-title":"Crit Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib15","first-page":"5603","article-title":"Circuit compliance compensation in lung protective ventilation","volume":"1","author":"Masselli","year":"2006","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"10.1016\/j.resinv.2014.03.002_bib16","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1007\/s00134-009-1467-7","article-title":"A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators","volume":"35","author":"Thille","year":"2009","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib17","doi-asserted-by":"crossref","first-page":"S228","DOI":"10.1097\/01.CCM.0000155920.11893.37","article-title":"Other approaches to open-lung ventilation: airway pressure release ventilation","volume":"33","author":"Habashi","year":"2005","journal-title":"Crit Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib18","first-page":"234","article-title":"Airway pressure release ventilation: theory and practice","volume":"12","author":"Frawley","year":"2001","journal-title":"AACN"},{"key":"10.1016\/j.resinv.2014.03.002_bib19","first-page":"517","article-title":"Airway pressure release ventilation: a new approach to ventilatory support during acute lung injury","volume":"32","author":"Stock","year":"1987","journal-title":"Respir Care"},{"key":"10.1016\/j.resinv.2014.03.002_bib20","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1093\/bja\/86.2.176","article-title":"Is pulmonary resistance constant, within the range of tidal volume ventilation, in patients with ARDS?","volume":"86","author":"Mols","year":"2001","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.resinv.2014.03.002_bib21","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/BF02738546","article-title":"A new approach for tracking respiratory mechanical parameters in real-time","volume":"25","author":"Avanzolini","year":"1997","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.resinv.2014.03.002_bib22","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1097\/00003246-199405000-00026","article-title":"Timing of pressure release affects power of breathing and minute ventilation during airway pressure release ventilation","volume":"22","author":"Putensen","year":"1994","journal-title":"Crit Care Med"},{"key":"10.1016\/j.resinv.2014.03.002_bib23","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1183\/09031936.01.00083901","article-title":"The effects of pressurization rate on breathing pattern, work of breathing, gas exchange and patient comfort in pressure support ventilation","volume":"18","author":"Chiumello","year":"2001","journal-title":"Eur Respir J"}],"container-title":["Respiratory Investigation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534514000276?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534514000276?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,7,12]],"date-time":"2023-07-12T10:57:01Z","timestamp":1689159421000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2212534514000276"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["S2212534514000276"],"URL":"https:\/\/doi.org\/10.1016\/j.resinv.2014.03.002","relation":{},"ISSN":["2212-5345"],"issn-type":[{"type":"print","value":"2212-5345"}],"subject":[],"published":{"date-parts":[[2014,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparing surrogates of oxygenation and ventilation between airway pressure release ventilation and biphasic airway pressure in a mechanical model of adult respiratory distress syndrome","name":"articletitle","label":"Article Title"},{"value":"Respiratory Investigation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resinv.2014.03.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 The Japanese Respiratory Society. Published by Elsevier Japan KK All rights reserved.","name":"copyright","label":"Copyright"}]}}