{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T13:13:03Z","timestamp":1778850783259,"version":"3.51.4"},"reference-count":19,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T00:00:00Z","timestamp":1773964800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Investigation"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.resinv.2026.101411","type":"journal-article","created":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T16:50:51Z","timestamp":1774457451000},"page":"101411","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of 22-gauge and 25-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration: A prospective observational study"],"prefix":"10.1016","volume":"64","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1103-4276","authenticated-orcid":false,"given":"Tadashi","family":"Sakaguchi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3263-2809","authenticated-orcid":false,"given":"Takeo","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Morikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoichi","family":"Nishii","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osamu","family":"Hataji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masamichi","family":"Mineshita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.resinv.2026.101411_bib1","doi-asserted-by":"crossref","first-page":"e211S","DOI":"10.1378\/chest.12-2355","article-title":"Methods for staging non-small cell lung cancer: diagnosis and management of lung cancer, 3rd ed: American college of chest physicians evidence-based clinical practice guidelines","volume":"143","author":"Silvestri","year":"2013","journal-title":"Chest"},{"key":"10.1016\/j.resinv.2026.101411_bib2","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1111\/crj.13436","article-title":"Comparing diagnostic sensitivity of different needle sizes for lymph nodes suspected of lung cancer in endobronchial ultrasound transbronchial needle aspiration: systematic review and meta-analysis","volume":"15","author":"Yu Lee-Mateus","year":"2021","journal-title":"Clin Res J"},{"key":"10.1016\/j.resinv.2026.101411_bib3","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1378\/chest.15-1216","article-title":"Technical aspects of endobronchial ultrasound-guided transbronchial needle aspiration: CHEST guideline and expert panel report","volume":"149","author":"Wahidi","year":"2016","journal-title":"Chest"},{"key":"10.1016\/j.resinv.2026.101411_bib4","doi-asserted-by":"crossref","first-page":"3643","DOI":"10.21037\/jtd.2019.04.20","article-title":"Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration","volume":"11","author":"Di Felice","year":"2019","journal-title":"J Thorac Dis"},{"key":"10.1016\/j.resinv.2026.101411_bib5","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1111\/1759-7714.13332","article-title":"Novel ProCore 25-gauge needle for endobronchial ultrasound-guided transbronchial needle aspiration reduces the puncture time and frequency, with comparable diagnostic rate for mediastinal and hilar lymphadenopathy","volume":"11","author":"Yang","year":"2020","journal-title":"Thorac Cancer"},{"key":"10.1016\/j.resinv.2026.101411_bib6","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.resinv.2020.10.003","article-title":"Comparison of the 22-gauge and 25-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration","volume":"59","author":"Sakaguchi","year":"2021","journal-title":"Respir Investig"},{"key":"10.1016\/j.resinv.2026.101411_bib7","doi-asserted-by":"crossref","first-page":"3745","DOI":"10.21037\/tlcr-21-480","article-title":"Comparison of the efficiency of endobronchial ultrasound-guided transbronchial needle aspiration using a 22G needle versus 25G needle for the diagnosis of lymph node metastasis in patients with lung cancer: a prospective randomized, crossover study","volume":"10","author":"Sakai","year":"2021","journal-title":"Transl Lung Cancer Res"},{"key":"10.1016\/j.resinv.2026.101411_bib8","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/LBR.0000000000000753","article-title":"Comparison of sample adequacy and diagnostic yield of the 21-G and 25-G EBUS TBNA needles","volume":"29","author":"Sood","year":"2022","journal-title":"J Bronchol Interv Pulmonol"},{"key":"10.1016\/j.resinv.2026.101411_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.cllc.2017.11.010","article-title":"Feasibility of endobronchial ultrasound-guided transbronchial needle aspiration cytology specimens for next generation sequencing in non-small-cell lung cancer","volume":"19","author":"Stoy","year":"2018","journal-title":"Clin Lung Cancer"},{"key":"10.1016\/j.resinv.2026.101411_bib10","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jasc.2021.10.003","article-title":"Prospective randomized trial to compare the safety, diagnostic yield and utility of 22-gauge and 19-gauge endobronchial ultrasound transbronchial needle aspirates and processing technique by cytology and histopathology","volume":"11","author":"Manley","year":"2022","journal-title":"J Am Soc Cytopathol"},{"key":"10.1016\/j.resinv.2026.101411_bib11","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1183\/09031936.00033011","article-title":"Cryobiopsy increases the diagnostic yield of endobronchial biopsy: a multicentre trial","volume":"39","author":"Hetzel","year":"2012","journal-title":"Eur Respir J"},{"key":"10.1016\/j.resinv.2026.101411_bib12","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/j.1440-1843.2010.01871.x","article-title":"Comparison of 21\u2010gauge and 22\u2010gauge aspiration needle during endobronchial ultrasound\u2010guided transbronchial needle aspiration","volume":"16","author":"Nakajima","year":"2010","journal-title":"Respirology"},{"key":"10.1016\/j.resinv.2026.101411_bib13","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/LBR.0b013e318233016c","article-title":"Randomized study of 21-gauge versus 22-gauge endobronchial ultrasound-guided transbronchial needle aspiration needles for sampling histology specimens","volume":"18","author":"Oki","year":"2011","journal-title":"J Bronchol Interv Pulmonol"},{"key":"10.1016\/j.resinv.2026.101411_bib14","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/LBR.0b013e3182273b41","article-title":"Comparison of 21-gauge and 22-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes","volume":"18","author":"Saji","year":"2011","journal-title":"J Bronchol Interv Pulmonol"},{"key":"10.1016\/j.resinv.2026.101411_bib15","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software 'EZR' for medical statistics","volume":"48","author":"Kanda","year":"2013","journal-title":"Bone Marrow Transplant"},{"key":"10.1016\/j.resinv.2026.101411_bib16","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1111\/resp.12293","article-title":"Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples","volume":"19","author":"Jeyabalan","year":"2014","journal-title":"Respirology"},{"key":"10.1016\/j.resinv.2026.101411_bib17","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1513\/AnnalsATS.202103-366OC","article-title":"Effect of needle size on diagnosis of sarcoidosis with endobronchial ultrasound-guided transbronchial needle aspiration: systematic review and meta-analysis","volume":"19","author":"Kassirian","year":"2022","journal-title":"Ann Am Thorac Soc"},{"key":"10.1016\/j.resinv.2026.101411_bib18","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.21037\/tlcr-22-120","article-title":"Preclinical evaluation of thin convex probe endobronchial ultrasound-guided transbronchial needle aspiration for intrapulmonary lesions","volume":"11","author":"Ishiwata","year":"2022","journal-title":"Transl Lung Cancer Res"},{"key":"10.1016\/j.resinv.2026.101411_bib19","article-title":"Evaluating the efficacy of thin convex-probe endobronchial ultrasound bronchoscope in cadaveric models","volume":"32","author":"Takashima","year":"2025","journal-title":"J Bronchol Interv Pulmonol"}],"container-title":["Respiratory Investigation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534526000456?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534526000456?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T12:58:17Z","timestamp":1778849897000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2212534526000456"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S2212534526000456"],"URL":"https:\/\/doi.org\/10.1016\/j.resinv.2026.101411","relation":{},"ISSN":["2212-5345"],"issn-type":[{"value":"2212-5345","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of 22-gauge and 25-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration: A prospective observational study","name":"articletitle","label":"Article Title"},{"value":"Respiratory Investigation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resinv.2026.101411","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V. on behalf of The Japanese Respiratory Society.","name":"copyright","label":"Copyright"}],"article-number":"101411"}}