{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T13:12:55Z","timestamp":1778850775593,"version":"3.51.4"},"reference-count":11,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100010486","name":"Teijin Pharma","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100010486","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Investigation"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.resinv.2026.101437","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T22:07:25Z","timestamp":1777932445000},"page":"101437","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of the Pulsox-Me500, a pulse oximeter with built-in accelerometer, as an obstructive sleep apnea screening device: A pilot study"],"prefix":"10.1016","volume":"64","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7215-9027","authenticated-orcid":false,"given":"Satoshi","family":"Hamada","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4617-2348","authenticated-orcid":false,"given":"Hironobu","family":"Sunadome","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kimihiko","family":"Murase","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maya","family":"Tojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7431-9044","authenticated-orcid":false,"given":"Toyohiro","family":"Hirai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9626-1090","authenticated-orcid":false,"given":"Susumu","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.resinv.2026.101437_bib1","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/S2213-2600(19)30198-5","article-title":"Estimation of the global prevalence and burden of obstructive sleep apnoea: a literature-based analysis","volume":"7","author":"Benjafield","year":"2019","journal-title":"Lancet Respir Med"},{"key":"10.1016\/j.resinv.2026.101437_bib2","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s11325-016-1393-1","article-title":"Meta-analysis of all-cause and cardiovascular mortality in obstructive sleep apnea with or without continuous positive airway pressure treatment","volume":"21","author":"Fu","year":"2017","journal-title":"Sleep Breath"},{"key":"10.1016\/j.resinv.2026.101437_bib3","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2015-007956","article-title":"Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography?","volume":"5","author":"Dawson","year":"2015","journal-title":"BMJ Open"},{"key":"10.1016\/j.resinv.2026.101437_bib4","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.5664\/jcsm.7230","article-title":"Use of actigraphy for the evaluation of sleep disorders and circadian rhythm sleep-wake disorders: an American academy of sleep medicine clinical practice guideline","volume":"14","author":"Smith","year":"2018","journal-title":"J Clin Sleep Med"},{"key":"10.1016\/j.resinv.2026.101437_bib5","series-title":"The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications version 2.1. Darien, IL","author":"Berry","year":"2014"},{"key":"10.1016\/j.resinv.2026.101437_bib7","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s11325-025-03329-9","article-title":"Objective evaluation of major depressive disorder using sleep electroencephalography measured by an in-home portable one-channel device: a preliminary study","volume":"29","author":"Kawamura","year":"2025","journal-title":"Sleep Breath"},{"key":"10.1016\/j.resinv.2026.101437_bib8","first-page":"88","article-title":"Comparison of the usability of an automatic sleep staging program via portable 1-channel electroencephalograph and manual sleep staging with traditional polysomnography","volume":"21","author":"Kawamura","year":"2022","journal-title":"Sleep Biol Rhythm"},{"key":"10.1016\/j.resinv.2026.101437_bib9","unstructured":"https:\/\/www.konicaminolta.jp\/healthcare\/products\/pulseoximeters\/pulsox-500i\/index.html. [Accessed 1 October 2025]."},{"key":"10.1016\/j.resinv.2026.101437_bib10","series-title":"Statistical methods for rates and proportions","first-page":"212","article-title":"The measurement of interrater agreement","author":"Fleis","year":"1981"},{"key":"10.1016\/j.resinv.2026.101437_bib11","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1164\/ajrccm.162.3.9908002","article-title":"Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome","volume":"162","author":"Portier","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.resinv.2026.101437_bib12","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.5664\/jcsm.7228","article-title":"Use of actigraphy for the evaluation of sleep disorders and circadian rhythm sleep-wake disorders: an American academy of sleep medicine systematic review, meta-analysis, and GRADE assessment","volume":"14","author":"Smith","year":"2018","journal-title":"J Clin Sleep Med"}],"container-title":["Respiratory Investigation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534526000717?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212534526000717?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T12:57:34Z","timestamp":1778849854000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2212534526000717"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S2212534526000717"],"URL":"https:\/\/doi.org\/10.1016\/j.resinv.2026.101437","relation":{},"ISSN":["2212-5345"],"issn-type":[{"value":"2212-5345","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy of the Pulsox-Me500, a pulse oximeter with built-in accelerometer, as an obstructive sleep apnea screening device: A pilot study","name":"articletitle","label":"Article Title"},{"value":"Respiratory Investigation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resinv.2026.101437","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Japanese Respiratory Society. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"101437"}}