{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T22:05:15Z","timestamp":1781215515720,"version":"3.54.1"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T00:00:00Z","timestamp":1768262400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Medicine and Research"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.resmer.2026.101248","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T16:32:56Z","timestamp":1768235576000},"page":"101248","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Vibrating mesh nebulization increases tidal volume relative to jet nebulization during NIV in COPD exacerbation"],"prefix":"10.1016","volume":"89","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4788-1189","authenticated-orcid":false,"given":"C\u00e9sar","family":"Cinesi-Gomez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mar\u00eda","family":"Garcia-Palacios","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorena","family":"Bernabe-Vera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mabel Coromoto","family":"Suarez-Pineda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisa","family":"Serrano-Carrasco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose Andres","family":"Sanchez-Nicolas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.resmer.2026.101248_bib0001","article-title":"Official ERS\/ATS clinical practice guideline: non-invasive ventilation for acute respiratory failure","volume":"50","author":"Rochwerg","year":"2017","journal-title":"Eur Respir J"},{"issue":"8","key":"10.1016\/j.resmer.2026.101248_bib0002","doi-asserted-by":"crossref","first-page":"821","DOI":"10.4187\/respcare.11069","article-title":"Respiratory care management of COPD exacerbations","volume":"68","author":"Hess","year":"2023","journal-title":"Respir Care"},{"issue":"5","key":"10.1016\/j.resmer.2026.101248_bib0003","doi-asserted-by":"crossref","first-page":"2553","DOI":"10.21037\/jtd.2020.03.27","article-title":"Non-invasive ventilation for acute respiratory failure: pressure-supporting ventilation vs pressure-controlled ventilation","volume":"12","author":"Nam","year":"2020","journal-title":"J Thorac Dis"},{"issue":"24","key":"10.1016\/j.resmer.2026.101248_bib0004","first-page":"2034","volume":"118","year":"2005","journal-title":"Chin Med J (Engl)"},{"issue":"9219","key":"10.1016\/j.resmer.2026.101248_bib0005","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1016\/S0140-6736(00)02323-0","article-title":"Early use of non-invasive ventilation for acute exacerbations of chronic obstructive pulmonary disease in general respiratory wards: a multicenter randomized controlled trial","volume":"355","author":"Plant","year":"2000","journal-title":"Lancet"},{"issue":"1","key":"10.1016\/j.resmer.2026.101248_bib0006","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1186\/s13054-024-04953-9","article-title":"Expiratory flow limitation during mechanical ventilation: real-time detection and physiological subtypes","volume":"28","author":"Junhasavasdikul","year":"2024","journal-title":"Crit Care"},{"issue":"1","key":"10.1016\/j.resmer.2026.101248_bib0007","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/s13613-023-01147-4","article-title":"Aerosol therapy in critically ill adult patients: a consensus statement on aerosol delivery strategies during various modes of respiratory support","volume":"13","author":"Li","year":"2023","journal-title":"Ann Intensive Care"},{"issue":"12","key":"10.1016\/j.resmer.2026.101248_bib0008","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.4187\/respcare.08470","article-title":"Innovation in aerosol drug delivery during mechanical ventilation in adults","volume":"65","author":"Berlinski","year":"2020","journal-title":"Respir Care"},{"issue":"6","key":"10.1016\/j.resmer.2026.101248_bib0009","doi-asserted-by":"crossref","first-page":"858","DOI":"10.4187\/respcare.03790","article-title":"Aerosol therapy in pulmonary intensive care","volume":"60","author":"Ari","year":"2015","journal-title":"Respir Care"},{"issue":"4","key":"10.1016\/j.resmer.2026.101248_bib0010","doi-asserted-by":"crossref","first-page":"438","DOI":"10.5578\/tt.20239613","article-title":"The key to success of AVAPS: emphasizing appropriate patient selection after fixed-level PS-NIV use in respiratory failure","volume":"71","author":"Briones Claudett","year":"2023","journal-title":"Tuberk Toraks"},{"issue":"2","key":"10.1016\/j.resmer.2026.101248_bib0011","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1007\/s00134-015-4114-5","article-title":"Aerosol therapy in intensive and intermediate care units: prospective observation of 2808 critically ill patients","volume":"42","author":"Ehrmann","year":"2016","journal-title":"Intensive Care Med"},{"issue":"7","key":"10.1016\/j.resmer.2026.101248_bib0012","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1111\/j.2042-7158.2010.01134.x","article-title":"In vitro characterization of nebulized dose during noninvasive ventilation","volume":"62","author":"Abdelrahim","year":"2010","journal-title":"J Pharm Pharmacol"},{"issue":"6","key":"10.1016\/j.resmer.2026.101248_bib0013","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1089\/jamp.2020.1665","article-title":"Comparison of vibrating mesh and jet nebulizers during noninvasive ventilation in acute exacerbation of chronic obstructive pulmonary disease","volume":"34","author":"Avdeev","year":"2021","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"7","key":"10.1016\/j.resmer.2026.101248_bib0014","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.4187\/respcare.02074","article-title":"Administration of albuterol using 4 different nebulizers placed in 4 different positions in an in vitro pediatric ventilator model","volume":"58","author":"Berlinski","year":"2013","journal-title":"Respir Care"},{"issue":"12","key":"10.1016\/j.resmer.2026.101248_bib0015","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.4187\/respcare.05501649","article-title":"Administration of albuterol during non-invasive ventilation","volume":"50","author":"Branconnier","year":"2005","journal-title":"Respir Care"},{"issue":"Suppl 10","key":"10.1016\/j.resmer.2026.101248_bib0016","article-title":"A prospectively designed chart review comparison of the vibrating mesh nebulizer versus the standard jet nebulizer for administering bronchodilators in patients with asthma and COPD in the emergency department","volume":"64","author":"Carragher","year":"2019","journal-title":"Respir Care"},{"issue":"9","key":"10.1016\/j.resmer.2026.101248_bib0017","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.4187\/respcare.03667","article-title":"Pulmonary deposition of radioaerosols using mesh and jet nebulizers during noninvasive ventilation in healthy subjects","volume":"60","author":"Galindo-Filho","year":"2015","journal-title":"Respir Care"},{"issue":"Suppl 3","key":"10.1016\/j.resmer.2026.101248_bib0018","doi-asserted-by":"crossref","first-page":"A251","DOI":"10.1136\/thoraxjnl-2016-209333.435","article-title":"P292 Pilot study to evaluate bronchodilator response during acute COPD exacerbation using a vibrating mesh nebulizer versus a jet nebulizer for bronchodilator administration","volume":"71","author":"Cushen","year":"2016","journal-title":"Thorax"},{"issue":"4","key":"10.1016\/j.resmer.2026.101248_bib0019","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.ajem.2017.10.067","article-title":"Comparison of bronchodilator administration with a vibrating mesh nebulizer and a standard jet nebulizer in the emergency department","volume":"36","author":"Dunne","year":"2018","journal-title":"Am J Emerg Med"},{"issue":"9","key":"10.1016\/j.resmer.2026.101248_bib0020","first-page":"837","article-title":"Non-invasive ventilation in acute respiratory failure","volume":"38","author":"Mas","year":"2014","journal-title":"Med Intensiva"},{"issue":"3","key":"10.1016\/j.resmer.2026.101248_bib0021","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1136\/thorax.57.3.192","article-title":"Non-invasive ventilation in acute respiratory failure","volume":"57","year":"2002","journal-title":"Thorax"},{"issue":"6","key":"10.1016\/j.resmer.2026.101248_bib0022","first-page":"543","article-title":"New aerosol delivery devices","volume":"21","author":"Singh","year":"2015","journal-title":"Curr Opin Pulm Med"},{"issue":"1","key":"10.1016\/j.resmer.2026.101248_bib0023","first-page":"33","article-title":"Vibrating mesh nebulisers \u2013 can greater drug delivery to the airways and lungs improve respiratory outcomes?","volume":"4","author":"Ehrmann","year":"2018","journal-title":"Eur Respir Pulm Dis"},{"key":"10.1016\/j.resmer.2026.101248_bib0024","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/1471-2466-13-12","article-title":"Noninvasive mechanical ventilation with medium-volume assured pressure support (AVAPS) in patients with chronic obstructive pulmonary disease and hypercapnic encephalopathy","volume":"13","author":"Briones Claudett","year":"2013","journal-title":"BMC Pulm Med"},{"issue":"12","key":"10.1016\/j.resmer.2026.101248_bib0025","first-page":"1057","article-title":"Titration of non-invasive positive pressure ventilation in chronic respiratory failure","volume":"61","author":"Tuggey","year":"2006","journal-title":"Thorax"}],"container-title":["Respiratory Medicine and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590041226000036?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590041226000036?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T12:13:14Z","timestamp":1780920794000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2590041226000036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":25,"alternative-id":["S2590041226000036"],"URL":"https:\/\/doi.org\/10.1016\/j.resmer.2026.101248","relation":{},"ISSN":["2590-0412"],"issn-type":[{"value":"2590-0412","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Vibrating mesh nebulization increases tidal volume relative to jet nebulization during NIV in COPD exacerbation","name":"articletitle","label":"Article Title"},{"value":"Respiratory Medicine and Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resmer.2026.101248","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}],"article-number":"101248"}}