{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T15:21:59Z","timestamp":1760368919694},"reference-count":29,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2011,1,1]],"date-time":"2011-01-01T00:00:00Z","timestamp":1293840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100002428","name":"Austrian Science Fund (FWF)","doi-asserted-by":"crossref","award":["L288-N13"],"award-info":[{"award-number":["L288-N13"]}],"id":[{"id":"10.13039\/501100002428","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Resuscitation"],"published-print":{"date-parts":[[2011,1]]},"DOI":"10.1016\/j.resuscitation.2010.08.034","type":"journal-article","created":{"date-parts":[[2010,10,18]],"date-time":"2010-10-18T05:45:28Z","timestamp":1287380728000},"page":"79-84","source":"Crossref","is-referenced-by-count":11,"title":["Use of independent component analysis for reducing CPR artefacts in human emergency ECGs"],"prefix":"10.1016","volume":"82","author":[{"given":"Marcus","family":"Granegger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Werther","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hermann","family":"Gilly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.resuscitation.2010.08.034_bib0005","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1109\/10.880095","article-title":"CPR artifact removal from human ECG using optimal multichannel filtering","volume":"47","author":"Aase","year":"2000","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0010","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.resuscitation.2003.12.019","article-title":"Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG","volume":"61","author":"Eilevstjonn","year":"2004","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0015","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1109\/TBME.2008.2010329","article-title":"A least mean-square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions","volume":"56","author":"Irusta","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0020","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.resuscitation.2007.03.007","article-title":"Rhythm discrimination during uninterrupted CPR using motion artifact reduction system","volume":"75","author":"Berger","year":"2007","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0025","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.resuscitation.2006.05.017","article-title":"Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts","volume":"72","author":"Aramendi","year":"2007","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0030","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.resuscitation.2007.08.002","article-title":"A method to remove CPR artefacts from human ECG using only the recorded ECG","volume":"76","author":"Ruiz de","year":"2008","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0035","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/1475-925X-9-2","article-title":"Reduction of CPR artefacts in the ventricular fibrillation ECG by coherent line removal","volume":"9","author":"Amann","year":"2010","journal-title":"Biomed Eng Online"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0040","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S0300-9572(00)00259-8","article-title":"Reducing CPR artefacts in ventricular fibrillation in vitro","volume":"48","author":"Langhelle","year":"2001","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0045","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1109\/TBME.2002.804591","article-title":"Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm","volume":"49","author":"Husoy","year":"2002","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0050","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1016\/j.resuscitation.2009.07.020","article-title":"Strong corruption of electrocardiograms caused by cardiopulmonary resuscitation reduces efficiency of two-channel methods for removing motion artefacts in non-shockable rhythms","volume":"80","author":"Werther","year":"2009","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0055","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1109\/TBME.2008.2003107","article-title":"CPR artifact removal in ventricular fibrillation ECG signals using Gabor multipliers","volume":"56","author":"Werther","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0060","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.resuscitation.2009.09.003","article-title":"Techniques for artefact filtering from chest compression corrupted ECG signals: good, but not enough","volume":"80","author":"Li","year":"2009","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0065","doi-asserted-by":"crossref","first-page":"R15","DOI":"10.1088\/0967-3334\/26\/1\/R02","article-title":"Independent component analysis for biomedical signals","volume":"26","author":"James","year":"2005","journal-title":"Physiol Meas"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0070","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/S0893-6080(00)00026-5","article-title":"Independent component analysis: algorithms and applications","volume":"13","author":"Hyvarinen","year":"2000","journal-title":"Neural Netw"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0075","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1515\/BMT.2007.005","article-title":"The role of independent component analysis in the signal processing of ECG recordings","volume":"52","author":"Castells","year":"2007","journal-title":"Biomed Tech (Berl)"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0080","doi-asserted-by":"crossref","first-page":"3391","DOI":"10.1109\/IEMBS.2006.260464","article-title":"Multichannel techniques for motion artifacts removal from electrocardiographic signals","volume":"1","author":"Milanesi","year":"2006","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0085","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s11517-007-0293-8","article-title":"Independent component analysis applied to the removal of motion artifacts from electrocardiographic signals","volume":"46","author":"Milanesi","year":"2008","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0090","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s00521-005-0013-y","article-title":"Application of ICA in removing artefacts from the ECG","volume":"15","author":"He","year":"2005","journal-title":"Neural Comput Appl"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0095","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.ijcard.2007.06.037","article-title":"Artifacts and noise removal in electrocardiograms using independent component analysis","volume":"129","author":"Chawla","year":"2008","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0100","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.resuscitation.2010.03.003","article-title":"Human ECGs corrupted with real CPR artefacts in an animal model: generating a database to evaluate and refine algorithms for eliminating CPR artefacts","volume":"81","author":"Granegger","year":"2010","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0105","series-title":"ICAcentral","author":"Cardoso","year":"2010"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0110","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1109\/TNN.2006.875991","article-title":"Efficient variant of algorithm FastICA for independent component analysis attaining the Cramer-Rao lower bound","volume":"17","author":"Koldovsky","year":"2006","journal-title":"IEEE Trans Neural Netw"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0115","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1109\/TBME.2008.919714","article-title":"Multichannel electrocardiogram decomposition using periodic component analysis","volume":"55","author":"Sameni","year":"2008","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0120","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1162\/089976699300016863","article-title":"High-order contrasts for independent component analysis","volume":"11","author":"Cardoso","year":"1999","journal-title":"Neural Comput"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0125","doi-asserted-by":"crossref","first-page":"S148","DOI":"10.1097\/00003246-200204001-00006","article-title":"Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation","volume":"30","author":"FitzGibbon","year":"2002","journal-title":"Crit Care Med"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0130","author":"Altman","year":"1991"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0135","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1007\/s11517-009-0452-1","article-title":"Independent component analysis: comparison of algorithms for the investigation of surface electrical brain activity","volume":"47","author":"Klemm","year":"2009","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0140","first-page":"4685","article-title":"Limitations of ICA for artefact removal","volume":"5","author":"Djuwari","year":"2005","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"10.1016\/j.resuscitation.2010.08.034_bib0145","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1161\/01.CIR.95.6.1677","volume":"95","author":"Kerber","year":"1997","journal-title":"Circulation"}],"container-title":["Resuscitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957210004636?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957210004636?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,5,6]],"date-time":"2020-05-06T20:39:17Z","timestamp":1588797557000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300957210004636"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,1]]}},"alternative-id":["S0300957210004636"],"URL":"https:\/\/doi.org\/10.1016\/j.resuscitation.2010.08.034","relation":{},"ISSN":["0300-9572"],"issn-type":[{"value":"0300-9572","type":"print"}],"subject":[],"published":{"date-parts":[[2011,1]]}}}