{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,4]],"date-time":"2024-07-04T18:00:38Z","timestamp":1720116038361},"reference-count":5,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2014,10,1]],"date-time":"2014-10-01T00:00:00Z","timestamp":1412121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["resuscitationjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Resuscitation"],"published-print":{"date-parts":[[2014,10]]},"DOI":"10.1016\/j.resuscitation.2014.04.034","type":"journal-article","created":{"date-parts":[[2014,6,26]],"date-time":"2014-06-26T06:15:23Z","timestamp":1403763323000},"page":"e167-e168","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["The presence of pacing artifacts may impede diagnosis of ventricular fibrillation during cardiac arrest"],"prefix":"10.1016","volume":"85","author":[{"given":"Dariusz","family":"Timler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dorota","family":"Zy\u015bko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward","family":"Ko\u017aluk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agnieszka","family":"Pi\u0105tkowska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomasz","family":"Grzebieniak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacek","family":"Gajek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olle","family":"Melander","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Artur","family":"Fedorowski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.resuscitation.2014.04.034_bib0005","doi-asserted-by":"crossref","first-page":"36","DOI":"10.22514\/SV81.052013.6","article-title":"Recognition of ventricular fibrillation concomitant with pacing artifacts","volume":"8","author":"Smereka","year":"2013","journal-title":"Signa Vitae"},{"key":"10.1016\/j.resuscitation.2014.04.034_bib0010","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.resuscitation.2005.01.017","article-title":"Pacemaker spikes misleading the diagnosis of ventricular fibrillation","volume":"66","author":"Bonvini","year":"2005","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2014.04.034_bib0015","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.resuscitation.2011.09.009","article-title":"Impact of resuscitation system errors on survival from in-hospital cardiac arrest","volume":"83","author":"Ornato","year":"2012","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2014.04.034_bib0020","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1253\/circj.72.679","article-title":"Inappropriate analyses of automated external defibrillators used during in-hospital ventricular fibrillation","volume":"72","author":"Yamamoto","year":"2008","journal-title":"Circ J"},{"key":"10.1016\/j.resuscitation.2014.04.034_bib0025","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1093\/europace\/eup196","article-title":"Undersensing of ventricular fibrillation due to interference between a pacemaker and defibrillator in the same patient","volume":"11","author":"Van Casteren","year":"2009","journal-title":"Europace"}],"container-title":["Resuscitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957214005851?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957214005851?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,8,11]],"date-time":"2019-08-11T19:08:18Z","timestamp":1565550498000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300957214005851"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10]]},"references-count":5,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["S0300957214005851"],"URL":"https:\/\/doi.org\/10.1016\/j.resuscitation.2014.04.034","relation":{},"ISSN":["0300-9572"],"issn-type":[{"value":"0300-9572","type":"print"}],"subject":[],"published":{"date-parts":[[2014,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The presence of pacing artifacts may impede diagnosis of ventricular fibrillation during cardiac arrest","name":"articletitle","label":"Article Title"},{"value":"Resuscitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resuscitation.2014.04.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}