{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:50:12Z","timestamp":1793145012073,"version":"4.5.0"},"reference-count":40,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","resuscitationjournal.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Resuscitation"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1016\/j.resuscitation.2017.01.002","type":"journal-article","created":{"date-parts":[[2017,1,19]],"date-time":"2017-01-19T12:14:06Z","timestamp":1484828046000},"page":"192-198","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":36,"special_numbering":"C","title":["Endotracheal tube placement confirmation: 100% sensitivity and specificity with sustained four-phase capnographic waveforms in a cadaveric experimental model"],"prefix":"10.1016","volume":"115","author":[{"given":"Salvatore","family":"Silvestri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay G.","family":"Ladde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8015-4768","authenticated-orcid":false,"given":"James F.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesus V.","family":"Roa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Hunter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George A.","family":"Ralls","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linda","family":"Papa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.resuscitation.2017.01.002_bib0005","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00000542-199502000-00007","article-title":"Death and other complications of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations","volume":"82","author":"Schwartz","year":"1995","journal-title":"Anesthesiology"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0010","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/S0735-6757(99)90046-3","article-title":"Complications of emergency intubation with and without paralysis","volume":"17","author":"Li","year":"1999","journal-title":"Am J Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0015","doi-asserted-by":"crossref","first-page":"S729","DOI":"10.1161\/CIRCULATIONAHA.110.970988","article-title":"Part 8: adult advanced cardiovascular life support: 2010. American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care science","volume":"122","author":"Neumar","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0020","first-page":"707","article-title":"Emergency physician-verified out-of-hospital intubation: miss rates by paramedics","volume":"11","author":"Jones","year":"2004","journal-title":"Acad Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0025","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0196-0644(98)70312-9","article-title":"Field trial of endotracheal intubation by basic EMTs","volume":"31","author":"Sayre","year":"1998","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0030","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1067\/mem.2001.112098","article-title":"Misplaced endotracheal tubes by paramedics in an urban emergency medical services system","volume":"37","author":"Katz","year":"2001","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0035","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1197\/S1069-6563(03)00315-4","article-title":"Unrecognized misplacement of endotracheal tubes in a mixed urban to rural emergency medical services setting","volume":"10","author":"Jemmett","year":"2003","journal-title":"Acad Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0040","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.resuscitation.2010.12.014","article-title":"Out-of-hospital airway management in the United States","volume":"82","author":"Wang","year":"2011","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0045","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.resuscitation.2014.02.032","article-title":"An update on out-of-hospital airway management practices in the United States","volume":"85","author":"Diggs","year":"2014","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0050","series-title":"Review panel of the Fourth National Audit Project. The 4th National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society Major complications of airway management in the United Kingdom: Report and findings","author":"Cook","year":"2011"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0055","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1111\/j.1365-2044.2011.06808.x","article-title":"The use of capnography to confirm tracheal intubation during cardiac arrest","volume":"66","author":"Edwards","year":"2011","journal-title":"Anaesthesia"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0060","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.resuscitation.2012.04.002","article-title":"Capnography during cardiopulmonary resuscitation","volume":"83","author":"Scarth","year":"2012","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0065","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/2036-7902-5-7","article-title":"A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation","volume":"5","author":"Adi","year":"2013","journal-title":"Crit Ultrasound J"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0070","first-page":"283","article-title":"Usefulness of bedside ultrasound compared to capnography and X-ray for tracheal intubation","volume":"81","author":"Quintela","year":"2014","journal-title":"An Pediatr"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0075","doi-asserted-by":"crossref","first-page":"S444","DOI":"10.1161\/CIR.0000000000000261","article-title":"Part 7: adult advanced cardiovascular life support: 2015. American Heart Association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care","volume":"132","author":"Link","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0080","article-title":"2005 American Heart Association guidelines for resuscitation and emergency cardiovascular care","volume":"112","author":"ECC Committee","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0085","doi-asserted-by":"crossref","first-page":"S876","DOI":"10.1161\/CIRCULATIONAHA.110.971101","article-title":"Part 14: pediatric advanced life support: 2010. American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care","volume":"122","author":"Kleinman","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0090","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.resuscitation.2012.08.329","article-title":"Appropriate documentation of confirmation of endotracheal tube position and relationship to patient outcome from in-hospital cardiac arrest","volume":"84","author":"Phelan","year":"2013","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0095","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1136\/emermed-2013-203105","article-title":"Sustained life-like waveform capnography after human cadaveric tracheal intubation","volume":"32","author":"Reid","year":"2015","journal-title":"Emerg Med J"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0100","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1136\/emermed-2015-204950","article-title":"End-tidal CO2 detection during cadaveric ventilation","volume":"32","author":"Coats","year":"2015","journal-title":"Emerg Med J"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0105","series-title":"Rosen\u2019s emergency medicine, concepts and clinical practice","first-page":"62","article-title":"Monitoring the emergency patient","author":"Napoli","year":"2013"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0110","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0736-4679(00)00318-8","article-title":"Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation","volume":"20","author":"Li","year":"2001","journal-title":"J Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0115","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/S0196-0644(05)82517-X","article-title":"Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device","volume":"21","author":"Ornato","year":"1992","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0120","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/S0196-0644(05)80937-0","article-title":"Verification of endotracheal tube placement with colorimetric end-tidal CO2 detection","volume":"20","author":"MacLeod","year":"1991","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0125","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1097\/00000542-200012000-00015","article-title":"Accuracy and reliability of the self-inflating bulb to verify tracheal intubation in out-of-hospital cardiac arrest patients","volume":"93","author":"Tanigawa","year":"2000","journal-title":"Anesthesiology"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0130","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1213\/00000539-200102000-00018","article-title":"The efficacy of esophageal detector devices in verifying tracheal tube placement: a randomized cross-over study of out-of-hospital cardiac arrest patients","volume":"92","author":"Tanigawa","year":"2001","journal-title":"Anesth Analg"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0135","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0300-9572(02)00345-3","article-title":"The assessment of three methods to verify tracheal tube placement in the emergency setting","volume":"56","author":"Takeda","year":"2003","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0140","series-title":"Verification of endotracheal tube placement","year":"2009"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0145","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1007\/s00134-002-1290-x","article-title":"Comparison of three different methods to confirm tracheal tube placement in emergency intubation","volume":"28","author":"Grmec","year":"2002","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0150","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0196-0644(05)80938-2","article-title":"A disposable end-tidal CO2 detector to verify endotracheal intubation","volume":"20","author":"Anton","year":"1991","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0155","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0196-0644(05)80148-9","article-title":"Validity of a disposable end-tidal CO2 detector in verifying endotracheal tube placement in infants and children","volume":"21","author":"Bhende","year":"1992","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0160","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1542\/peds.95.3.395","article-title":"Evaluation of an end-tidal CO2 detector during pediatric cardiopulmonary resuscitation","volume":"95","author":"Bhende","year":"1995","journal-title":"Pediatrics"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0165","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1111\/j.1553-2712.1995.tb03247.x","article-title":"Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest","volume":"2","author":"Hayden","year":"1995","journal-title":"Acad Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0170","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.annemergmed.2004.09.014","article-title":"The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system","volume":"45","author":"Silvestri","year":"2005","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0175","doi-asserted-by":"crossref","first-page":"332","DOI":"10.4103\/0974-2700.142778","article-title":"Capnography during cardiopulmonary resuscitation: current evidence and future directions","volume":"7","author":"Kodali","year":"2014","journal-title":"J Emerg Trauma Shock"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0180","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1016\/j.resuscitation.2011.05.016","article-title":"Tracheal rapid ultrasound exam (T.R.U.E.) for confirming endotracheal tube placement during emergency intubation","volume":"82","author":"Chou","year":"2011","journal-title":"Resuscitation"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0185","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/S0196-0644(05)81557-4","article-title":"End-tidal CO2 measurement in the detection of esophageal intubation during cardiac arrest","volume":"19","author":"Sayah","year":"1990","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0190","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.2527\/jas.2005-590","article-title":"Effects of condensed tannins supplementation level on weight gain and in vitro and in vivo bloat precursors in steers grazing winter wheat","volume":"84","author":"Min","year":"2006","journal-title":"J Anim Sci"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0195","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1097\/PAF.0b013e3181dd17b9","article-title":"Putrefactive rigor: apparent rigor mortis due to gas distension","volume":"32","author":"Gil","year":"2011","journal-title":"Am J Forensic Med Pathol"},{"key":"10.1016\/j.resuscitation.2017.01.002_bib0200","first-page":"190","article-title":"Beyond the grave\u2014understanding human decomposition","volume":"28","author":"Vass","year":"2001","journal-title":"Microbiol Today"}],"container-title":["Resuscitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957217300114?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0300957217300114?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T02:15:16Z","timestamp":1658456116000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0300957217300114"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":40,"alternative-id":["S0300957217300114"],"URL":"https:\/\/doi.org\/10.1016\/j.resuscitation.2017.01.002","relation":{},"ISSN":["0300-9572"],"issn-type":[{"value":"0300-9572","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Endotracheal tube placement confirmation: 100% sensitivity and specificity with sustained four-phase capnographic waveforms in a cadaveric experimental model","name":"articletitle","label":"Article Title"},{"value":"Resuscitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.resuscitation.2017.01.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}