{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T06:07:42Z","timestamp":1790489262307,"version":"4.1.0"},"reference-count":53,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T00:00:00Z","timestamp":1456790400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T00:00:00Z","timestamp":1456790400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"vor","delay-in-days":730,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","resmedjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Medicine"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1016\/j.rmed.2016.01.017","type":"journal-article","created":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T02:01:09Z","timestamp":1453860069000},"page":"112-118","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":72,"special_numbering":"C","title":["Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation"],"prefix":"10.1016","volume":"112","author":[{"given":"Sigurd","family":"Aarrestad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elin","family":"Tollefsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne Louise","family":"Kleiven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magnus","family":"Qvarfort","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul","family":"Janssens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ole Henning","family":"Skj\u00f8nsberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.rmed.2016.01.017_bib1","doi-asserted-by":"crossref","first-page":"289S","DOI":"10.1378\/chest.113.5_Supplement.289S","article-title":"Mechanical ventilation beyond the intensive care unit: report of a consensus conference of the American College of Chest Physicians","volume":"113","author":"Make","year":"1998","journal-title":"Chest"},{"key":"10.1016\/j.rmed.2016.01.017_bib2","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1136\/thx.2010.139782","article-title":"Nocturnal monitoring of home non-invasive ventilation: the contribution of simple tools such as pulse oximetry, capnography, built-in ventilator software and autonomic markers of sleep fragmentation","volume":"66","author":"Janssens","year":"2011","journal-title":"Thorax"},{"key":"10.1016\/j.rmed.2016.01.017_bib3","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.4187\/respcare.02829","article-title":"The importance of controlling PaCO(2) throughout long-term noninvasive ventilation","volume":"59","author":"Tsuboi","year":"2014","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib4","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1016\/j.rmed.2010.08.013","article-title":"Predictors of mortality in chest wall disease treated with noninvasive home mechanical ventilation","volume":"104","author":"Marti","year":"2010","journal-title":"Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib5","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1111\/j.1440-1843.2007.01086.x","article-title":"Predictors of long-term survival in patients with restrictive thoracic disorders and chronic respiratory failure undergoing non-invasive home ventilation","volume":"12","author":"Budweiser","year":"2007","journal-title":"Respirology"},{"key":"10.1016\/j.rmed.2016.01.017_bib6","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/S2213-2600(14)70153-5","article-title":"Non-invasive positive pressure ventilation for the treatment of severe stable chronic obstructive pulmonary disease: a prospective, multicentre, randomised, controlled clinical trial","volume":"2","author":"Kohnlein","year":"2014","journal-title":"Lancet Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib7","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1136\/bmj.281.6233.128","article-title":"Arterial puncture","volume":"281","author":"Flenley","year":"1980","journal-title":"Br. Med. J."},{"key":"10.1016\/j.rmed.2016.01.017_bib8","first-page":"597","article-title":"Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine","volume":"8","author":"Berry","year":"2012","journal-title":"J.\u00a0Clin. sleep Med.: JCSM : Off. Publ. Am. Acad. Sleep Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib9","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1007\/s00134-009-1408-5","article-title":"Carbon dioxide monitoring during long-term noninvasive respiratory support in children","volume":"35","author":"Paiva","year":"2009","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib10","doi-asserted-by":"crossref","first-page":"126","DOI":"10.5535\/arm.2012.36.1.126","article-title":"The significance of transcutaneous continuous overnight CO(2) monitoring in determining initial mechanical ventilator application for patients with neuromuscular disease","volume":"36","author":"Lee","year":"2012","journal-title":"Ann. Rehabilit. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib11","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.4187\/respcare.01658","article-title":"Nocturnal oximetry and transcutaneous carbon dioxide in home-ventilated neuromuscular patients","volume":"57","author":"Nardi","year":"2012","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib12","doi-asserted-by":"crossref","first-page":"S48","DOI":"10.1213\/01.ane.0000278642.16117.f8","article-title":"The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions","volume":"105","author":"Eberhard","year":"2007","journal-title":"Anesth. Analgesia"},{"key":"10.1016\/j.rmed.2016.01.017_bib13","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1159\/000083990","article-title":"Non-invasive (transcutaneous) monitoring of PCO2 (TcPCO2) in older adults","volume":"51","author":"Janssens","year":"2005","journal-title":"Gerontology"},{"key":"10.1016\/j.rmed.2016.01.017_bib14","doi-asserted-by":"crossref","first-page":"1872","DOI":"10.1016\/j.ajem.2012.03.033","article-title":"Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED","volume":"30","author":"Delerme","year":"2012","journal-title":"Am. J. Emerg. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib15","doi-asserted-by":"crossref","first-page":"528","DOI":"10.3109\/17482968.2012.688836","article-title":"Using transcutaneous carbon dioxide monitor (TOSCA 500) to detect respiratory failure in patients with amyotrophic lateral sclerosis: a validation study","volume":"13","author":"Rafiq","year":"2012","journal-title":"Amyotroph. Lateral Scler.: Off. Publ. World Fed. Neurol. Res. Group Mot. Neuron Dis."},{"key":"10.1016\/j.rmed.2016.01.017_bib16","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1007\/s00134-008-1078-8","article-title":"Evaluation of a transcutaneous carbon dioxide monitor in severe obesity","volume":"34","author":"Maniscalco","year":"2008","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib17","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1159\/000187631","article-title":"Accuracy of transcutaneous carbon dioxide tension measurements during cardiopulmonary exercise testing","volume":"78","author":"Stege","year":"2009","journal-title":"Respiration"},{"key":"10.1016\/j.rmed.2016.01.017_bib18","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.rmed.2010.11.010","article-title":"Agreement between arterial and transcutaneous PCO2 in patients undergoing non-invasive ventilation","volume":"105","author":"Kelly","year":"2011","journal-title":"Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib19","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1111\/j.1445-5994.2010.02213.x","article-title":"Assessing PaCO2 in acute respiratory disease: accuracy of a transcutaneous carbon dioxide device","volume":"41","author":"Perrin","year":"2011","journal-title":"Intern. Med. J."},{"key":"10.1016\/j.rmed.2016.01.017_bib20","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1111\/j.1365-2044.2007.04987.x","article-title":"The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems","volume":"62","author":"Bolliger","year":"2007","journal-title":"Anaesthesia"},{"key":"10.1016\/j.rmed.2016.01.017_bib21","doi-asserted-by":"crossref","first-page":"e91563","DOI":"10.1371\/journal.pone.0091563","article-title":"The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery","volume":"9","author":"Liu","year":"2014","journal-title":"PloS one"},{"key":"10.1016\/j.rmed.2016.01.017_bib22","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1053\/rmed.2001.1045","article-title":"Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?","volume":"95","author":"Janssens","year":"2001","journal-title":"Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib23","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1034\/j.1399-3003.1999.13e18.x","article-title":"Validity of transcutaneous oxygen\/carbon dioxide pressure measurement in the monitoring of mechanical ventilation in stable chronic respiratory failure","volume":"13","author":"Rosner","year":"1999","journal-title":"Eur. Respir. J."},{"key":"10.1016\/j.rmed.2016.01.017_bib24","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1378\/chest.127.5.1744","article-title":"Limitations of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation","volume":"127","author":"Cuvelier","year":"2005","journal-title":"Chest"},{"key":"10.1016\/j.rmed.2016.01.017_bib25","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.rmed.2010.10.007","article-title":"Transcutaneous monitoring as a replacement for arterial PCO(2) monitoring during nocturnal non-invasive ventilation","volume":"105","author":"Storre","year":"2011","journal-title":"Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib26","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1159\/000323074","article-title":"Validation of a transcutaneous CO(2) monitor in adult patients with chronic respiratory failure","volume":"81","author":"Hazenberg","year":"2011","journal-title":"Respiration"},{"key":"10.1016\/j.rmed.2016.01.017_bib27","doi-asserted-by":"crossref","first-page":"2203","DOI":"10.1097\/01.CCM.0000181734.26070.26","article-title":"Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor","volume":"33","author":"Bendjelid","year":"2005","journal-title":"Crit. Care Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib28","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1378\/chest.07-1173","article-title":"Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation","volume":"132","author":"Storre","year":"2007","journal-title":"Chest"},{"key":"10.1016\/j.rmed.2016.01.017_bib29","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1378\/chest.113.3.768","article-title":"Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device","volume":"113","author":"Janssens","year":"1998","journal-title":"Chest"},{"key":"10.1016\/j.rmed.2016.01.017_bib30","doi-asserted-by":"crossref","first-page":"442","DOI":"10.4187\/respcare.00454","article-title":"Transcutaneous measurement of carbon dioxide tension during extended monitoring: evaluation of accuracy and stability, and an algorithm for correcting calibration drift","volume":"56","author":"Berlowitz","year":"2011","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib31","series-title":"Non-Invasive Ventilation & Weaning: Principles and Practice","first-page":"151","article-title":"Diagnostic tests in the assessment of patients for home mechanical ventilation","author":"Murphy","year":"2010"},{"key":"10.1016\/j.rmed.2016.01.017_bib32","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.4187\/respcare.02011","article-title":"AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012","volume":"57","author":"Restrepo","year":"2012","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib33","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s00540-006-0422-9","article-title":"Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension","volume":"20","author":"Nishiyama","year":"2006","journal-title":"J.\u00a0Anesth."},{"key":"10.1016\/j.rmed.2016.01.017_bib34","first-page":"638","article-title":"[Transcutaneous P(CO2) (TcP(CO2)) reflects Pa(CO2) of previous 1 or 2 minutes]","volume":"61","author":"Kuzuta","year":"2012","journal-title":"Masui. Jpn. J. Anesthesiol."},{"key":"10.1016\/j.rmed.2016.01.017_bib35","doi-asserted-by":"crossref","first-page":"217","DOI":"10.4103\/1817-1737.84776","article-title":"Evaluation of a transcutaneous carbon dioxide monitor in patients with acute respiratory failure","volume":"6","author":"Nicolini","year":"2011","journal-title":"Ann. Thorac. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib36","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s00134-005-0006-4","article-title":"Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients","volume":"32","author":"Rodriguez","year":"2006","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib37","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s10877-011-9311-3","article-title":"Comparison of ear and chest probes in transcutaneous carbon dioxide pressure measurements during general anesthesia in adults","volume":"25","author":"Nishiyama","year":"2011","journal-title":"J.\u00a0Clin. Monit. Comput."},{"key":"10.1016\/j.rmed.2016.01.017_bib38","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1093\/bja\/aeq092","article-title":"Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements","volume":"104","author":"De Oliveira","year":"2010","journal-title":"Br. J. Anaesth."},{"key":"10.1016\/j.rmed.2016.01.017_bib39","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1213\/ANE.0b013e3181e30b54","article-title":"Transcutaneous carbon dioxide monitoring accurately predicts arterial carbon dioxide partial pressure in patients undergoing prolonged laparoscopic surgery","volume":"111","author":"Xue","year":"2010","journal-title":"Anesth. Analgesia"},{"key":"10.1016\/j.rmed.2016.01.017_bib40","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1053\/j.jvca.2009.06.015","article-title":"Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements","volume":"24","author":"Chakravarthy","year":"2010","journal-title":"J.\u00a0Cardiothorac. Vasc. Anesth."},{"key":"10.1016\/j.rmed.2016.01.017_bib41","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1007\/s00540-008-0734-z","article-title":"Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors","volume":"23","author":"Hirabayashi","year":"2009","journal-title":"J.\u00a0Anesth."},{"key":"10.1016\/j.rmed.2016.01.017_bib42","first-page":"10","article-title":"Accuracy and precision of three different methods to determine Pco2 (Paco2 vs. Petco2 vs. Ptcco2) during interhospital ground transport of critically ill and ventilated adults","volume":"65","author":"Hinkelbein","year":"2008","journal-title":"J.\u00a0Trauma"},{"key":"10.1016\/j.rmed.2016.01.017_bib43","first-page":"1042","article-title":"Transcutaneous carbon dioxide pressure monitoring in a specialized weaning unit","volume":"53","author":"Johnson","year":"2008","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib44","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1378\/chest.128.3.1291","article-title":"Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea","volume":"128","author":"Senn","year":"2005","journal-title":"Chest"},{"key":"10.1016\/j.rmed.2016.01.017_bib45","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1159\/000295904","article-title":"Evaluation of a system for transcutaneous long-term capnometry","volume":"80","author":"Randerath","year":"2010","journal-title":"Respiration"},{"key":"10.1016\/j.rmed.2016.01.017_bib46","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.rmed.2006.05.011","article-title":"Evaluation of a transcutaneous carbon dioxide monitor (\u201cTOSCA\u201d) in adult patients in routine respiratory practice","volume":"101","author":"Parker","year":"2007","journal-title":"Respir. Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib47","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1017\/S0265021506001116","article-title":"Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia","volume":"23","author":"Nishiyama","year":"2006","journal-title":"Eur. J. Anaesthesiol."},{"key":"10.1016\/j.rmed.2016.01.017_bib48","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s00134-010-2076-1","article-title":"Accuracy of a transcutaneous carbon dioxide pressure monitoring device in emergency room patients with acute respiratory failure","volume":"37","author":"Gancel","year":"2011","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2016.01.017_bib49","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1136\/emj.2007.055715","article-title":"Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department","volume":"26","author":"Mcvicar","year":"2009","journal-title":"Emerg. Med. J.: EMJ"},{"key":"10.1016\/j.rmed.2016.01.017_bib50","first-page":"1162","article-title":"An evaluation of a transcutaneous and an end-tidal capnometer for noninvasive monitoring of spontaneously breathing patients","volume":"51","author":"Stein","year":"2006","journal-title":"Respir. Care"},{"key":"10.1016\/j.rmed.2016.01.017_bib51","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1136\/thx.2005.051664","article-title":"Non-invasive monitoring of CO2 levels in patients using NIV for AECOPD","volume":"61","author":"Cox","year":"2006","journal-title":"Thorax"},{"key":"10.1016\/j.rmed.2016.01.017_bib52","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1111\/j.1440-1843.2008.01442.x","article-title":"Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjects","volume":"14","author":"Fuke","year":"2009","journal-title":"Respirology"},{"key":"10.1016\/j.rmed.2016.01.017_bib53","first-page":"375","article-title":"Transcutaneous carbon dioxide monitoring in spontaneously breathing, nonintubated patients in the early postoperative period","volume":"74","author":"Fanelli","year":"2008","journal-title":"Minerva Anestesiol."}],"container-title":["Respiratory Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0954611116300130?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0954611116300130?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T11:34:22Z","timestamp":1760614462000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0954611116300130"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3]]},"references-count":53,"alternative-id":["S0954611116300130"],"URL":"https:\/\/doi.org\/10.1016\/j.rmed.2016.01.017","relation":{},"ISSN":["0954-6111"],"issn-type":[{"value":"0954-6111","type":"print"}],"subject":[],"published":{"date-parts":[[2016,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation","name":"articletitle","label":"Article Title"},{"value":"Respiratory Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.rmed.2016.01.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}