{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T00:17:17Z","timestamp":1791505037676,"version":"4.3.4"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","resmedjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Respiratory Medicine"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1016\/j.rmed.2025.108413","type":"journal-article","created":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T06:41:51Z","timestamp":1760078511000},"page":"108413","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["A comprehensive overview of ventilation intensity and mutual relationship with mechanical power, strain and ventilatory ratio"],"prefix":"10.1016","volume":"249","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2168-9017","authenticated-orcid":false,"given":"Lorenzo","family":"Schiavoni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7571-6121","authenticated-orcid":false,"given":"Alessia","family":"Mattei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8319-9662","authenticated-orcid":false,"given":"Alessandro","family":"Ruggiero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3505-1153","authenticated-orcid":false,"given":"Alessandro","family":"Strumia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.rmed.2025.108413_bib1","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1164\/ajrccm\/137.5.1159","article-title":"High inflation pressure pulmonary edema. Respective effects of high airway pressure, high tidal volume, and positive end-expiratory pressure","volume":"137","author":"Dreyfuss","year":"1988","journal-title":"Am. Rev. Respir. Dis."},{"key":"10.1016\/j.rmed.2025.108413_bib2","doi-asserted-by":"crossref","first-page":"395","DOI":"10.21037\/atm.2018.08.17","article-title":"Is the mechanical power the final word on ventilator-induced lung injury?-we are not sure","volume":"6","author":"Vasques","year":"2018","journal-title":"Ann. Transl. Med."},{"key":"10.1016\/j.rmed.2025.108413_bib3","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/S2213-2600(20)30325-8","article-title":"Time-varying intensity of mechanical ventilation and mortality in patients with acute respiratory failure: a registry-based, prospective cohort study","volume":"8","author":"Urner","year":"2020","journal-title":"Lancet Respir. Med."},{"key":"10.1016\/j.rmed.2025.108413_bib4","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1186\/s13054-021-03710-6","article-title":"PRoVENT\u2013COVID collaborative group, association of intensity of ventilation with 28-day mortality in COVID-19 patients with acute respiratory failure: insights from the PRoVENT-COVID study","volume":"25","author":"Schuijt","year":"2021","journal-title":"Crit. Care"},{"key":"10.1016\/j.rmed.2025.108413_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcrc.2024.154531","article-title":"ERICC, LUNG SAFE, PRoVENT, PRoVENT-iMiC-investigators, different ventilation intensities among various categories of patients ventilated for reasons other than ARDS--A pooled analysis of 4 observational studies","volume":"81","author":"Serafini","year":"2024","journal-title":"J. Crit. Care"},{"key":"10.1016\/j.rmed.2025.108413_bib6","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/EJA.0000000000001778","article-title":"For the NEBULAE, PReVENT, RELAx investigators, effect of mechanical power on mortality in invasively ventilated ICU patients without the acute respiratory distress syndrome: an analysis of three randomised clinical trials","volume":"40","author":"van Meenen","year":"2023","journal-title":"Eur. J. Anaesthesiol."},{"key":"10.1016\/j.rmed.2025.108413_bib7","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/s13054-020-03428-x","article-title":"Mechanical power during extracorporeal membrane oxygenation and hospital mortality in patients with acute respiratory distress syndrome","volume":"25","author":"Chiu","year":"2021","journal-title":"Crit. Care"},{"key":"10.1016\/j.rmed.2025.108413_bib8","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1513\/AnnalsATS.201812-910OC","article-title":"Epidemiology, mechanical power, and 3-Year outcomes in acute respiratory distress syndrome patients using standardized screening. An observational cohort study","volume":"16","author":"Parhar","year":"2019","journal-title":"Ann Am Thorac Soc"},{"key":"10.1016\/j.rmed.2025.108413_bib9","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1007\/s00134-016-4505-2","article-title":"Ventilator-related causes of lung injury: the mechanical power","volume":"42","author":"Gattinoni","year":"2016","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib10","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1186\/s13054-017-1750-x","article-title":"The future of mechanical ventilation: lessons from the present and the past","volume":"21","author":"Gattinoni","year":"2017","journal-title":"Crit. Care"},{"key":"10.1016\/j.rmed.2025.108413_bib11","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1164\/rccm.202009-3467OC","article-title":"Ventilatory variables and mechanical power in patients with acute respiratory distress syndrome","volume":"204","author":"Costa","year":"2021","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib12","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1007\/s00134-019-05698-8","article-title":"Calculating mechanical power for pressure-controlled ventilation","volume":"45","author":"van der Meijden","year":"2019","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib13","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s40635-022-00448-5","article-title":"Simple, accurate calculation of mechanical power in pressure controlled ventilation (PCV)","volume":"10","author":"Trinkle","year":"2022","journal-title":"Intensive Care Med Exp"},{"key":"10.1016\/j.rmed.2025.108413_bib14","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1007\/s00134-019-05636-8","article-title":"Calculation of mechanical power for pressure-controlled ventilation","volume":"45","author":"Becher","year":"2019","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib15","first-page":"e1224","article-title":"Mechanical power in pressure-controlled ventilation: a simple and reliable bedside method","volume":"7","author":"Snoep","year":"2025","journal-title":"Crit Care Explor"},{"key":"10.1016\/j.rmed.2025.108413_bib16","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1097\/ALN.0000000000001056","article-title":"Mechanical power and development of ventilator-induced lung injury","volume":"124","author":"Cressoni","year":"2016","journal-title":"Anesthesiology"},{"key":"10.1016\/j.rmed.2025.108413_bib17","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1007\/s00134-018-5375-6","article-title":"PROVE network investigators, mechanical power of ventilation is associated with mortality in critically ill patients: an analysis of patients in two observational cohorts","volume":"44","author":"Serpa Neto","year":"2018","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib18","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/ALN.0000000000002458","article-title":"Positive end-expiratory pressure and mechanical power","volume":"130","author":"Collino","year":"2019","journal-title":"Anesthesiology"},{"key":"10.1016\/j.rmed.2025.108413_bib19","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1007\/s00134-009-1510-8","article-title":"Is there an optimal breath pattern to minimize stress and strain during mechanical ventilation?","volume":"35","author":"Brunner","year":"2009","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib20","doi-asserted-by":"crossref","DOI":"10.1177\/17534666231155744","article-title":"Ventilatory ratio and mechanical power in prolonged mechanically ventilated COVID-19 patients versus respiratory failures of other etiologies","volume":"17","author":"Ghiani","year":"2023","journal-title":"Ther. Adv. Respir. Dis."},{"key":"10.1016\/j.rmed.2025.108413_bib21","doi-asserted-by":"crossref","DOI":"10.3389\/fmed.2025.1553672","article-title":"Associations of mechanical power, ventilatory ratio, and other respiratory indices with mortality in patients with acute respiratory distress syndrome undergoing pressure-controlled mechanical ventilation","volume":"12","author":"Kim","year":"2025","journal-title":"Front. Med."},{"key":"10.1016\/j.rmed.2025.108413_bib22","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.medin.2024.05.007","article-title":"Association of dead space fraction to mortality in patients with COVID-19-related ARDS: a historical cohort observational study","volume":"48","author":"Carvajal","year":"2024","journal-title":"Med. Intensiva"},{"key":"10.1016\/j.rmed.2025.108413_bib23","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1186\/s13613-025-01514-3","article-title":"Omics approach to chest electrical impedance tomography reveals physiological cluster of ARDS characterised by increased respiratory drive and effort","volume":"15","author":"Mauri","year":"2025","journal-title":"Ann. Intensive Care"},{"key":"10.1016\/j.rmed.2025.108413_bib24","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1007\/s00134-005-2627-z","article-title":"The concept of \u201cbaby lung,\u201d","volume":"31","author":"Gattinoni","year":"2005","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib25","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s00134-024-07352-4","article-title":"Measuring patient's effort on the ventilator","volume":"50","author":"Cornejo","year":"2024","journal-title":"Intensive Care Med."},{"key":"10.1016\/j.rmed.2025.108413_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcrc.2024.154851","article-title":"Letter to the editor: \u201cdifferent ventilation intensities among various categories of patients ventilated for reasons other than ARDS - a pooled analysis of 4 observational studies.,\u201d","volume":"83","author":"Schiavoni","year":"2024","journal-title":"J. Crit. Care"}],"container-title":["Respiratory Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0954611125004767?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0954611125004767?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T02:08:54Z","timestamp":1763690934000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0954611125004767"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":26,"alternative-id":["S0954611125004767"],"URL":"https:\/\/doi.org\/10.1016\/j.rmed.2025.108413","relation":{},"ISSN":["0954-6111"],"issn-type":[{"value":"0954-6111","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A comprehensive overview of ventilation intensity and mutual relationship with mechanical power, strain and ventilatory ratio","name":"articletitle","label":"Article Title"},{"value":"Respiratory Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.rmed.2025.108413","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"108413"}}