{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T14:43:53Z","timestamp":1781016233627,"version":"3.54.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013302","name":"King Abdullah International Medical Research Center","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100013302","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Saudi Dental Journal"],"published-print":{"date-parts":[[2021,11]]},"DOI":"10.1016\/j.sdentj.2020.07.005","type":"journal-article","created":{"date-parts":[[2020,8,6]],"date-time":"2020-08-06T01:52:32Z","timestamp":1596678752000},"page":"614-619","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Evidence for reduced torsional resistance of rotary files under curved position"],"prefix":"10.1007","volume":"33","author":[{"given":"Ahmed","family":"Jamleh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raghad","family":"Almedlej","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rasha","family":"Alomar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nouf","family":"Almayouf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulmohsen","family":"Alfadley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalid","family":"Alfouzan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"issue":"10","key":"10.1016\/j.sdentj.2020.07.005_b0005","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1016\/j.joen.2018.07.009","article-title":"Effects of sodium hypochlorite concentration and temperature on the cyclic fatigue resistance of heat-treated nickel-titanium rotary instruments","volume":"44","author":"Alfawaz","year":"2018","journal-title":"J. Endod."},{"issue":"1","key":"10.1016\/j.sdentj.2020.07.005_b0010","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1186\/s12903-019-0820-7","article-title":"Torsional resistance of three ProTaper rotary systems","volume":"19","author":"Alqedairi","year":"2019","journal-title":"BMC Oral Health"},{"issue":"9","key":"10.1016\/j.sdentj.2020.07.005_b0015","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.joen.2011.05.032","article-title":"Comparison of torsional stiffness of nickel-titanium rotary files with different geometric characteristics","volume":"37","author":"Baek","year":"2011","journal-title":"J. Endod."},{"issue":"6","key":"10.1016\/j.sdentj.2020.07.005_b0020","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.dental.2007.09.004","article-title":"Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution","volume":"24","author":"Cheung","year":"2008","journal-title":"Dent. Mat."},{"issue":"7","key":"10.1016\/j.sdentj.2020.07.005_b0025","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1016\/j.joen.2015.02.011","article-title":"In vivo intracanal temperature evolution during endodontic treatment after the injection of room temperature or preheated sodium hypochlorite","volume":"41","author":"de Hemptinne","year":"2015","journal-title":"J. Endod."},{"issue":"1","key":"10.1016\/j.sdentj.2020.07.005_b0030","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jebdp.2017.08.001","article-title":"In vivo and in vitro effectiveness of rotary nickel-titanium vs manual stainless steel instruments for root canal therapy: systematic review and meta-analysis","volume":"18","author":"Del Fabbro","year":"2018","journal-title":"J. Evid. Based. Dent. Pract."},{"issue":"11","key":"10.1016\/j.sdentj.2020.07.005_b0035","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1111\/iej.12244","article-title":"Cyclic fatigue resistance of ProTaper next nickel-titanium rotary files","volume":"47","author":"Elnaghy","year":"2014","journal-title":"Int. Endod. J."},{"issue":"11","key":"10.1016\/j.sdentj.2020.07.005_b0040","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1111\/iej.12557","article-title":"Mechanical properties of ProTaper Gold nickel-titanium rotary instruments","volume":"49","author":"Elnaghy","year":"2016","journal-title":"Int. Endod. J."},{"issue":"8","key":"10.1016\/j.sdentj.2020.07.005_b0045","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1111\/iej.12700","article-title":"Laboratory comparison of the mechanical properties of TRUShape with several nickel-titanium rotary instruments","volume":"50","author":"Elnaghy","year":"2017","journal-title":"Int. Endod. J."},{"issue":"5","key":"10.1016\/j.sdentj.2020.07.005_b0050","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1111\/iej.12815","article-title":"Torsional resistance of XP-endo Shaper at body temperature compared with several nickel-titanium rotary instruments","volume":"51","author":"Elnaghy","year":"2018","journal-title":"Int.l Endod. J."},{"issue":"3","key":"10.1016\/j.sdentj.2020.07.005_b0055","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/S0099-2399(06)80441-3","article-title":"A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-flex endodontic instruments","volume":"21","author":"Glossen","year":"1995","journal-title":"J. Endod."},{"issue":"11","key":"10.1016\/j.sdentj.2020.07.005_b0060","doi-asserted-by":"crossref","first-page":"1872","DOI":"10.1016\/j.joen.2017.05.025","article-title":"Mechanical properties of various heat-treated nickel-titanium rotary instruments","volume":"43","author":"Goo","year":"2017","journal-title":"J. Endod."},{"issue":"7","key":"10.1016\/j.sdentj.2020.07.005_b0065","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/j.joen.2017.01.040","article-title":"Environmental temperature drastically affects flexural fatigue resistance of nickel-titanium rotary files","volume":"43","author":"Grande","year":"2017","journal-title":"J. Endod."},{"issue":"3","key":"10.1016\/j.sdentj.2020.07.005_b0070","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/j.joen.2016.10.032","article-title":"Effect from rotational speed on torsional resistance of the nickel-titanium instruments","volume":"43","author":"Ha","year":"2017","journal-title":"J Endod."},{"issue":"4","key":"10.1016\/j.sdentj.2020.07.005_b0075","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1111\/j.1365-2591.2007.01203.x","article-title":"Phase transformation behaviour and bending properties of hybrid nickel-titanium rotary endodontic instruments","volume":"40","author":"Hayashi","year":"2007","journal-title":"Int. Endod. J."},{"issue":"7","key":"10.1016\/j.sdentj.2020.07.005_b0080","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.joen.2015.02.030","article-title":"Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments","volume":"41","author":"Hieawy","year":"2015","journal-title":"J. Endod."},{"issue":"3","key":"10.1016\/j.sdentj.2020.07.005_b0085","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1007\/s10266-015-0214-5","article-title":"Performance of NiTi endodontic instrument under different temperatures","volume":"104","author":"Jamleh","year":"2016","journal-title":"Odontology"},{"issue":"4","key":"10.1016\/j.sdentj.2020.07.005_b0090","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1067\/moe.2000.108959","article-title":"A comparison of stainless steel and nickel\u2013titanium H-type instruments of identical design: torsional and bending tests","volume":"90","author":"Kazemi","year":"2000","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod."},{"issue":"1","key":"10.1016\/j.sdentj.2020.07.005_b0095","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1111\/j.1365-2591.2008.01481.x","article-title":"Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis","volume":"42","author":"Kim","year":"2009","journal-title":"Int. Endod. J."},{"issue":"10","key":"10.1016\/j.sdentj.2020.07.005_b0100","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/00004770-200210000-00009","article-title":"Fatigue and mechanical properties of nickel-titanium endodontic instruments","volume":"28","author":"Kuhn","year":"2002","journal-title":"J. Endod."},{"issue":"2","key":"10.1016\/j.sdentj.2020.07.005_b0105","doi-asserted-by":"crossref","first-page":"247","DOI":"10.4012\/dmj.25.247","article-title":"Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments","volume":"25","author":"Li","year":"2006","journal-title":"Dent. Mater. J."},{"issue":"2","key":"10.1016\/j.sdentj.2020.07.005_b0110","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1365-2591.2006.01055.x","article-title":"Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments","volume":"39","author":"Miyai","year":"2006","journal-title":"Int. Endod. J."},{"issue":"1","key":"10.1016\/j.sdentj.2020.07.005_b0115","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.joen.2015.10.004","article-title":"Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining","volume":"42","author":"Pedull\u00e0","year":"2016","journal-title":"J. Endod."},{"issue":"9","key":"10.1016\/j.sdentj.2020.07.005_b0120","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1111\/j.1365-2591.2005.00997.x","article-title":"Shaping ability of two rotary instruments in simulated canals: stainless steel ENDOflash and nickel\u2013titanium HERO Shaper","volume":"38","author":"Perez","year":"2005","journal-title":"Int. Endod. J."},{"issue":"5","key":"10.1016\/j.sdentj.2020.07.005_b0125","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.joen.2007.01.007","article-title":"Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments","volume":"33","author":"Peters","year":"2007","journal-title":"J. Endod."},{"key":"10.1016\/j.sdentj.2020.07.005_b0130","doi-asserted-by":"crossref","unstructured":"Revised ANSI\/ADA specifications No. 28 for root canal files and reamers, type K, and No. 58 for root canal files, type H (Hedstrom),1989. Council on Dental Materials, Instruments, and Equipment. J. Am. Dent. Assoc. 118:239\u201340.","DOI":"10.14219\/jada.archive.1989.0230"},{"issue":"3","key":"10.1016\/j.sdentj.2020.07.005_b0135","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00004770-200003000-00008","article-title":"Defects in rotary nickel-titanium files after clinical use","volume":"26","author":"Sattapan","year":"2000","journal-title":"J. Endod."},{"issue":"1","key":"10.1016\/j.sdentj.2020.07.005_b0140","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1111\/etp.12046","article-title":"Methods and models to study nickel-titanium instruments","volume":"29","author":"Shen","year":"2013","journal-title":"Endod. Topics"},{"issue":"3","key":"10.1016\/j.sdentj.2020.07.005_b0145","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.joen.2011.12.002","article-title":"Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments","volume":"38","author":"Shen","year":"2012","journal-title":"J. Endod."},{"issue":"12","key":"10.1016\/j.sdentj.2020.07.005_b0150","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1097\/01.don.0000164127.62864.7c","article-title":"The impact of instrument fracture on outcome of endodontic treatment","volume":"31","author":"Spili","year":"2005","journal-title":"J. Endod."},{"issue":"4","key":"10.1016\/j.sdentj.2020.07.005_b0155","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1046\/j.1365-2591.2000.00339.x","article-title":"An overview of nickel-titanium alloys used in dentistry","volume":"33","author":"Thompson","year":"2000","journal-title":"Int. Endod. J."},{"issue":"4","key":"10.1016\/j.sdentj.2020.07.005_b0160","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.joen.2005.08.012","article-title":"Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections","volume":"32","author":"Xu","year":"2006","journal-title":"J. Endod."},{"issue":"7","key":"10.1016\/j.sdentj.2020.07.005_b0165","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1111\/j.1365-2591.2009.01563.x","article-title":"Effect of heat treatment on transformation temperatures and bending properties of nickel titanium endodontic instruments","volume":"42","author":"Yahata","year":"2009","journal-title":"Int. Endod. J."}],"container-title":["The Saudi Dental Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S101390522030746X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S101390522030746X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,1,6]],"date-time":"2025-01-06T17:28:03Z","timestamp":1736184483000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S101390522030746X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["S101390522030746X"],"URL":"https:\/\/doi.org\/10.1016\/j.sdentj.2020.07.005","relation":{},"ISSN":["1013-9052"],"issn-type":[{"value":"1013-9052","type":"print"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evidence for reduced torsional resistance of rotary files under curved position","name":"articletitle","label":"Article Title"},{"value":"The Saudi Dental Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.sdentj.2020.07.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/).","name":"copyright","label":"Copyright"}]}}