{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T03:40:54Z","timestamp":1771299654160,"version":"3.50.1"},"reference-count":40,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T00:00:00Z","timestamp":1716422400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100010571","name":"Federal Ministry of Education and Research Berlin Office","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100010571","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["VDI 161L0250D"],"award-info":[{"award-number":["VDI 161L0250D"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["slas-technology.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["SLAS Technology"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1016\/j.slast.2024.100148","type":"journal-article","created":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T16:34:16Z","timestamp":1716654856000},"page":"100148","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Achieving near-zero particle generation by simplicity of design\u2014A compliant-mechanism-based gripper for clean-room environments"],"prefix":"10.1016","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7064-0762","authenticated-orcid":false,"given":"Leon","family":"Budde","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakob","family":"Hentschel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7495-3141","authenticated-orcid":false,"given":"Sontje","family":"Ihler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6920-1690","authenticated-orcid":false,"given":"Thomas","family":"Seel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.slast.2024.100148_b1","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2020.571777","article-title":"Automation in the life science research laboratory","volume":"8","author":"Holland","year":"2020","journal-title":"Front Bioeng Biotechnol","ISSN":"https:\/\/id.crossref.org\/issn\/2296-4185","issn-type":"print"},{"key":"10.1016\/j.slast.2024.100148_b2","doi-asserted-by":"crossref","DOI":"10.1016\/j.jobe.2021.103083","article-title":"Field test of pharmaceutical cleanroom cleanliness subject to multiple disturbance factors","volume":"42","author":"Yang","year":"2021","journal-title":"J Build Eng","ISSN":"https:\/\/id.crossref.org\/issn\/2352-7102","issn-type":"print"},{"issue":"1","key":"10.1016\/j.slast.2024.100148_b3","doi-asserted-by":"crossref","first-page":"4464","DOI":"10.1038\/s41467-020-18130-3","article-title":"A role for Biofoundries in rapid development and validation of automated SARS-CoV-2 clinical diagnostics","volume":"11","author":"Crone","year":"2020","journal-title":"Nature Commun","ISSN":"https:\/\/id.crossref.org\/issn\/2041-1723","issn-type":"print"},{"key":"10.1016\/j.slast.2024.100148_b4","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2020.00811","article-title":"Automation, monitoring, and standardization of cell product manufacturing","volume":"8","author":"Doulgkeroglou","year":"2020","journal-title":"Front Bioeng Biotechnol","ISSN":"https:\/\/id.crossref.org\/issn\/2296-4185","issn-type":"print"},{"key":"10.1016\/j.slast.2024.100148_b5","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.procir.2018.03.189","article-title":"Highly modular and generic control software for adaptive cell processing on automated production platforms","volume":"72","author":"Jung","year":"2018","journal-title":"Procedia CIRP","ISSN":"https:\/\/id.crossref.org\/issn\/2212-8271","issn-type":"print"},{"issue":"19","key":"10.1016\/j.slast.2024.100148_b6","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1161\/CIRCULATIONAHA.116.024145","article-title":"Defined engineered human myocardium with advanced maturation for applications in heart failure modeling and repair","volume":"135","author":"Tiburcy","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.slast.2024.100148_b7","series-title":"ISO14644-1:2015 cleanrooms and associated controlled environments; Part 1: Classification of air cleanliness by particle concentration","author":"International Organization for Standardization","year":"2015"},{"key":"10.1016\/j.slast.2024.100148_b8","series-title":"ANSI\/SLAS Microplate Standards","author":"The Society for Laboratory Automation and Screening","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b9","unstructured":"Lee M-H, Cho H-S. Vacuum gripper for carrying a semiconductor wafer. 19625846A1, 1997, URL:."},{"issue":"2","key":"10.1016\/j.slast.2024.100148_b10","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1109\/28.833768","article-title":"Fundamental characteristics of electrostatic wafer chuck with insulating sealant","volume":"36","author":"Yatsuzuka","year":"2000","journal-title":"IEEE Trans Ind Appl","ISSN":"https:\/\/id.crossref.org\/issn\/0093-9994","issn-type":"print"},{"key":"10.1016\/j.slast.2024.100148_b11","series-title":"SS-GMP","author":"GIMATIC","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b12","series-title":"LS-GMP","author":"GIMATIC","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b13","series-title":"Kraftvolles Leichtgewicht - Reinraumtauglicher Pneumatikgreifer","author":"Poguntke","year":"2024"},{"key":"10.1016\/j.slast.2024.100148_b14","series-title":"MPPM1606","author":"GIMATIC","year":"2024"},{"key":"10.1016\/j.slast.2024.100148_b15","series-title":"21st century kinematics: the 2012 NSF Workshop","year":"2013"},{"key":"10.1016\/j.slast.2024.100148_b16","series-title":"Ein Beitrag zur geometrischen Gestaltung und Optimierung prismatischer Festk\u00f6rpergelenke in nachgiebigen Koppelmechanismen","author":"Lin\u00df","year":"2015"},{"key":"10.1016\/j.slast.2024.100148_b17","series-title":"Handbook of compliant mechanisms","isbn-type":"print","year":"2013","ISBN":"https:\/\/id.crossref.org\/isbn\/9781119953456"},{"key":"10.1016\/j.slast.2024.100148_b18","series-title":"Clean bearing arrangement in the cost-effective gripper for microtiter plates in the laboratory","author":"IGUS","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b19","series-title":"Produkt\u00fcbersicht Rote Serie","author":"MONOLITIX","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b20","article-title":"Roboterkomponenten f\u00fcr den kryogenen Arbeitsraum : Entwicklung von Festk\u00f6rpergelenken und monolithischen Greifersystemen f\u00fcr eine Parallelroboterstruktur","author":"Jahn","year":"2020","journal-title":"Deutsche K\u00e4 lte- und Klimatagung 2020"},{"key":"10.1016\/j.slast.2024.100148_b21","series-title":"lab-hand","author":"8-BOT robotics","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b22","series-title":"The Gripster","author":"Let\u2019s Go Robotics","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b23","series-title":"SYBOT-1000 & CYTOMAT","author":"SYNENTEC","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b24","series-title":"SG - 2-finger","author":"EFFECTO","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b25","series-title":"Pneumatic Gripper","author":"Let\u2019s Go Robotics","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b26","series-title":"DPG-plus","author":"Schunk","year":"2023"},{"issue":"3","key":"10.1016\/j.slast.2024.100148_b27","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1166\/jnn.2020.17355","article-title":"Mechanical gripper design and force analysis of microplates for automated high-throughput nucleic acid detection system","volume":"20","author":"Wang","year":"2020","journal-title":"J Nanosci Nanotechnol"},{"key":"10.1016\/j.slast.2024.100148_b28","series-title":"2007 IEEE international conference on automation science and engineering","first-page":"846","article-title":"Design considerations for a minimally invasive high-throughput automation system for radiation biodosimetry","author":"Salerno","year":"2007"},{"key":"10.1016\/j.slast.2024.100148_b29","series-title":"Gripping mechanism, apperatus, and methods; Patent No.: US 6,932,557 B2","author":"Downs","year":"2005"},{"key":"10.1016\/j.slast.2024.100148_b30","series-title":"Design and manufacturing of active microsystems","isbn-type":"print","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/978-3-642-12903-2_19","article-title":"Design of a microassembly process based on hot melt adhesives","author":"Rathmann","year":"2011","ISBN":"https:\/\/id.crossref.org\/isbn\/9783642129032"},{"issue":"3","key":"10.1016\/j.slast.2024.100148_b31","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s43452-020-00085-3","article-title":"Design and test of a compact compliant gripper using the Scott\u2013Russell mechanism","volume":"20","author":"Zhu","year":"2020","journal-title":"Arch Civ Mech Eng","ISSN":"https:\/\/id.crossref.org\/issn\/1644-9665","issn-type":"print"},{"issue":"10","key":"10.1016\/j.slast.2024.100148_b32","doi-asserted-by":"crossref","first-page":"707","DOI":"10.3390\/mi10100707","article-title":"A disposable pneumatic microgripper for cell manipulation with image-based force sensing","volume":"10","author":"Gursky","year":"2019","journal-title":"Micromachines","ISSN":"https:\/\/id.crossref.org\/issn\/2072-666X","issn-type":"print"},{"key":"10.1016\/j.slast.2024.100148_b33","series-title":"Grabber D885","author":"MONOLITIX","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b34","series-title":"PAL SYSTEM: PAL RTC","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b35","series-title":"Coefficient of friction equation and table chart","author":"Engineers Edge","year":"2023"},{"key":"10.1016\/j.slast.2024.100148_b36","series-title":"Voice coil actuators vs. Solenoids: What is the difference?","author":"H2W Technologies Inc.","year":"2024"},{"key":"10.1016\/j.slast.2024.100148_b37","series-title":"Statistische Versuchsplanung","author":"Siebertz","year":"2017"},{"key":"10.1016\/j.slast.2024.100148_b38","series-title":"ISO14644-14:2016 Cleanrooms and associated controlled environments; Part 14: Assessment of suitability for use of equipment by airborne particle concentration","author":"International Organization for Standardization","year":"2016"},{"issue":"2","key":"10.1016\/j.slast.2024.100148_b39","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1515\/cdbme-2022-1036","article-title":"A six degree of freedom extrusion bioprinter","volume":"8","author":"Budde","year":"2022","journal-title":"Curr Direct Biomed Eng"},{"key":"10.1016\/j.slast.2024.100148_b40","doi-asserted-by":"crossref","DOI":"10.1016\/j.enbuild.2019.109346","article-title":"Energy demand reduction in pharmaceutical cleanrooms through optimization of ventilation","volume":"202","author":"Loomans","year":"2019","journal-title":"Energy Build"}],"container-title":["SLAS Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S247263032400030X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S247263032400030X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T05:05:42Z","timestamp":1747285542000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S247263032400030X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["S247263032400030X"],"URL":"https:\/\/doi.org\/10.1016\/j.slast.2024.100148","relation":{},"ISSN":["2472-6303"],"issn-type":[{"value":"2472-6303","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Achieving near-zero particle generation by simplicity of design\u2014A compliant-mechanism-based gripper for clean-room environments","name":"articletitle","label":"Article Title"},{"value":"SLAS Technology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.slast.2024.100148","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of Society for Laboratory Automation and Screening.","name":"copyright","label":"Copyright"}],"article-number":"100148"}}