{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T21:50:26Z","timestamp":1790632226654,"version":"4.1.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2014,8,1]],"date-time":"2014-08-01T00:00:00Z","timestamp":1406851200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["patient-research.elsevier.com","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2014,8]]},"DOI":"10.1016\/j.spinee.2013.09.035","type":"journal-article","created":{"date-parts":[[2013,10,19]],"date-time":"2013-10-19T02:30:41Z","timestamp":1382149841000},"page":"1572-1580","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":72,"title":["Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures: validity revisited"],"prefix":"10.1016","volume":"14","author":[{"given":"Parthasarathy D.","family":"Thirumala","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lance","family":"Bodily","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Derrick","family":"Tint","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. Timothy","family":"Ward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent F.","family":"Deeney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donald J.","family":"Crammond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel E.","family":"Habeych","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey R.","family":"Balzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2013.09.035_bib1","series-title":"Intraoperative monitoring of neural function. Handbook of clinical neurophysiology","first-page":"608","article-title":"Monitoring during the surgical treatment of scoliosis","volume":"8","author":"Nuwer","year":"2008"},{"key":"10.1016\/j.spinee.2013.09.035_bib2","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/0013-4694(94)00235-D","article-title":"Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey","volume":"96","author":"Nuwer","year":"1995","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.1016\/j.spinee.2013.09.035_bib3","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1097\/BRS.0b013e3181ec5fd9","article-title":"Rates of new neurological deficit associated with spine surgery based on 108,419 procedures: a report of the scoliosis research Society Morbidity and Mortality Committee","volume":"36","author":"Hamilton","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib4","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.2106\/JBJS.F.01476","article-title":"Neurophysiological detection of impending spinal cord injury during scoliosis surgery","volume":"89","author":"Schwartz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.spinee.2013.09.035_bib5","doi-asserted-by":"crossref","first-page":"S105","DOI":"10.1007\/s00586-011-1756-z","article-title":"The prevention of neural complications in the surgical treatment of scoliosis: the role of neurophysiological intraoperative monitoring","volume":"20","author":"Pastorelli","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2013.09.035_bib6","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1302\/0301-620X.73B3.1670455","article-title":"Spinal cord monitoring in scoliosis surgery. Experience with 1168 cases","volume":"73","author":"Forbes","year":"1991","journal-title":"J Bone Joint Surg Br"},{"issue":"2 Suppl","key":"10.1016\/j.spinee.2013.09.035_bib7","doi-asserted-by":"crossref","first-page":"S171","DOI":"10.1007\/s00586-007-0426-7","article-title":"Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoracolumbar spine surgeries","volume":"16","author":"Macdonald","year":"2007","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2013.09.035_bib8","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1097\/00006123-199806000-00074","article-title":"Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompression and instrumentation","volume":"42","author":"Balzer","year":"1998","journal-title":"Neurosurgery"},{"key":"10.1016\/j.spinee.2013.09.035_bib9","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1097\/01.bsd.0000133465.89618.c8","article-title":"Variability of somatosensory evoked potential monitoring during scoliosis surgery","volume":"17","author":"Chen","year":"2004","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2013.09.035_bib10","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1097\/00007632-198711000-00007","article-title":"Response variability of somatosensory-evoked potentials during scoliosis surgery","volume":"12","author":"York","year":"1987","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib11","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/0006-8993(79)90922-3","article-title":"Effects of reduced cerebral blood flow upon EEG pattern, cerebral extracellular potassium, energy metabolism in the rat cortex during bicucullin-induced seizures","volume":"177","author":"Astrup","year":"1979","journal-title":"Brain Res"},{"key":"10.1016\/j.spinee.2013.09.035_bib12","doi-asserted-by":"crossref","first-page":"E105","DOI":"10.1097\/01.brs.0000200163.71909.1f","article-title":"Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: experience with 508 cases","volume":"31","author":"Khan","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib13","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1038\/jcbfm.2009.188","article-title":"Cerebral blood flow response to functional activation","volume":"30","author":"Paulson","year":"2010","journal-title":"J Cereb Blood Flow Metab"},{"key":"10.1016\/j.spinee.2013.09.035_bib14","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1161\/01.STR.17.6.1183","article-title":"Autoregulation of spinal cord blood flow: is the cord a microcosm of the brain?","volume":"17","author":"Hickey","year":"1986","journal-title":"Stroke"},{"issue":"1 Suppl Operative","key":"10.1016\/j.spinee.2013.09.035_bib15","first-page":"ons64","article-title":"Somatosensory evoked potential monitoring during endoscopic endonasal approach to skull base surgery: analysis of observed change","volume":"69","author":"Thirumala","year":"2011","journal-title":"Neurosurgery"},{"key":"10.1016\/j.spinee.2013.09.035_bib16","first-page":"175","article-title":"The relationship between CBF, evoked potentials, and the clinical features of cerebral ischaemia","volume":"78","author":"Symon","year":"1980","journal-title":"Acta Neurol Scand Suppl"},{"key":"10.1016\/j.spinee.2013.09.035_bib17","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/00004311-199603440-00005","article-title":"Intraoperative neurophysiological monitoring","volume":"34","author":"Lopez","year":"1996","journal-title":"Int Anesthesiol Clin"},{"key":"10.1016\/j.spinee.2013.09.035_bib18","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.neucli.2004.01.001","article-title":"Electroencephalography (EEG) and somatosensory evoked potentials (SEP) to prevent cerebral ischaemia in the operating room","volume":"34","author":"Florence","year":"2004","journal-title":"Neurophysiol Clin"},{"key":"10.1016\/j.spinee.2013.09.035_bib19","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.spinee.2006.04.008","article-title":"Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients\u2014review of 1,039 cases","volume":"7","author":"Smith","year":"2007","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2013.09.035_bib20","doi-asserted-by":"crossref","first-page":"1538","DOI":"10.1213\/01.ane.0000198666.11523.d6","article-title":"The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: a retrospective analysis","volume":"102","author":"Kamel","year":"2006","journal-title":"Anesth Analg"},{"key":"10.1016\/j.spinee.2013.09.035_bib21","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s10877-006-9032-1","article-title":"Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery","volume":"20","author":"Schwartz","year":"2006","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.spinee.2013.09.035_bib22","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1097\/00006123-199809000-00050","article-title":"The predictive value of intraoperative somatosensory evoked potential monitoring: review of 244 procedures","volume":"43","author":"Bejjani","year":"1998","journal-title":"Neurosurgery"},{"key":"10.1016\/j.spinee.2013.09.035_bib23","doi-asserted-by":"crossref","first-page":"1970","DOI":"10.1097\/01.brs.0000176321.02963.72","article-title":"Somatosensory evoked potential monitoring during anterior cervical discectomy and fusion","volume":"30","author":"Taunt","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib24","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1016\/S1388-2457(02)00027-5","article-title":"Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery","volume":"113","author":"Pelosi","year":"2002","journal-title":"Clin Neurophysiol"},{"key":"10.1016\/j.spinee.2013.09.035_bib25","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1097\/00007632-200204150-00009","article-title":"Factors related to false- versus true-positive neuromonitoring changes in adolescent idiopathic scoliosis surgery","volume":"27","author":"Noonan","year":"2002","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib26","doi-asserted-by":"crossref","first-page":"64","DOI":"10.4103\/0019-5413.58608","article-title":"Multimodal intraoperative neuromonitoring in corrective surgery for adolescent idiopathic scoliosis: evaluation of 354 consecutive cases","volume":"44","author":"Kundnani","year":"2010","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.spinee.2013.09.035_bib27","doi-asserted-by":"crossref","first-page":"1916","DOI":"10.1097\/01.brs.0000228724.01795.a2","article-title":"Characterization of neurophysiologic alerts during anterior cervical spine surgery","volume":"31","author":"Lee","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib28","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1097\/BRS.0b013e3181ecbe77","article-title":"Transcranial electric motor evoked potential monitoring during spine surgery: is it safe?","volume":"36","author":"Schwartz","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2013.09.035_bib29","unstructured":"Nuvasive. Nuvasive signs agreement to acquire impulse monitoring. 2011. Available from: http:\/\/www.nuvasive.com\/news\/nuvasive-signs-agreement-to-acquire-impulse-monitoring\/. Accessed June 27,\u00a02012."}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943013015751?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943013015751?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,7,31]],"date-time":"2019-07-31T00:44:32Z","timestamp":1564533872000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943013015751"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8]]},"references-count":29,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["S1529943013015751"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2013.09.035","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2014,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures: validity revisited","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2013.09.035","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}