{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T18:35:11Z","timestamp":1764873311910},"reference-count":55,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["patient-research.elsevier.com","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2014,9]]},"DOI":"10.1016\/j.spinee.2014.03.001","type":"journal-article","created":{"date-parts":[[2014,3,17]],"date-time":"2014-03-17T00:00:40Z","timestamp":1395014440000},"page":"2195-2207","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Effects of cervical arthrodesis and arthroplasty on neck response during a simulated frontal automobile collision"],"prefix":"10.1016","volume":"14","author":[{"given":"Nicholas A.","family":"White","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel P.","family":"Moreno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip J.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. Scott","family":"Gayzik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wesley","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander K.","family":"Powers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joel D.","family":"Stitzel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2014.03.001_bib1","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00007632-199105000-00002","article-title":"Analysis and prevention of spinal column deformity following cervical laminectomy. I. Pathogenetic analysis of postlaminectomy deformities","volume":"16","author":"Saito","year":"1991","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib2","first-page":"221","article-title":"Finite element analysis of anterior cervical spine interbody fusion","volume":"7","author":"Kumaresan","year":"1997","journal-title":"Biomed Mater Eng"},{"key":"10.1016\/j.spinee.2014.03.001_bib3","first-page":"27","article-title":"Biomechanical effect of anterior cervical spine fusion on adjacent segments","volume":"9","author":"Maiman","year":"1999","journal-title":"Biomed Mater Eng"},{"key":"10.1016\/j.spinee.2014.03.001_bib4","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1097\/00007632-200004150-00010","article-title":"Anterior cervical fusion: a finite element model study on motion segment stability including the effect of osteoporosis","volume":"25","author":"Natarajan","year":"2000","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib5","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/s10237-006-0015-4","article-title":"Biomechanics of the C5-C6 spinal unit before and after placement of a disc prosthesis","volume":"5","author":"Galbusera","year":"2006","journal-title":"Biomech Model Mechanobiol"},{"key":"10.1016\/j.spinee.2014.03.001_bib6","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.medengphy.2005.09.006","article-title":"Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc","volume":"28","author":"Ha","year":"2006","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2014.03.001_bib7","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1097\/01.brs.0000215205.66437.c3","article-title":"Multilevel cervical fusion and its effect on disc degeneration and osteophyte formation","volume":"31","author":"Lopez-Espina","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib8","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1097\/BRS.0b013e318166e01d","article-title":"Biomechanics of the anterior longitudinal ligament during 8 g whiplash simulation following single- and contiguous two-level fusion: a finite element study","volume":"33","author":"Dang","year":"2008","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib9","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1016\/j.medengphy.2008.02.002","article-title":"Cervical spine biomechanics following implantation of a disc prosthesis","volume":"30","author":"Galbusera","year":"2008","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2014.03.001_bib10","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.1097\/BRS.0b013e31815e62ea","article-title":"Influence of the geometry of a ball-and-socket intervertebral prosthesis at the cervical spine: a finite element study","volume":"33","author":"Rousseau","year":"2008","journal-title":"Spine"},{"issue":"5 Suppl","key":"10.1016\/j.spinee.2014.03.001_bib11","doi-asserted-by":"crossref","first-page":"S653","DOI":"10.1007\/s00586-009-1211-6","article-title":"Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation","volume":"21","author":"Faizan","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2014.03.001_bib12","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1097\/BRS.0b013e3181aa643b","article-title":"Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in\u00a0vivo image-based finite element study","volume":"34","author":"Lin","year":"2009","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib13","series-title":"Computational modeling of the lower cervical spine facet cartilage distribution and disc replacement","author":"Womack","year":"2009"},{"key":"10.1016\/j.spinee.2014.03.001_bib14","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/2010.3.FOCUS1063","article-title":"Biomechanics of a posture-controlling cervical artificial disc: mechanical, in\u00a0vitro, and finite-element analysis","volume":"28","author":"Crawford","year":"2010","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.spinee.2014.03.001_bib15","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.clinbiomech.2010.01.010","article-title":"The influence of the axial, antero-posterior and lateral positions of the center of rotation of a ball-and-socket disc prosthesis on the cervical spine biomechanics","volume":"25","author":"Galbusera","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.spinee.2014.03.001_bib16","doi-asserted-by":"crossref","first-page":"E9","DOI":"10.3171\/2010.3.FOCUS1046","article-title":"Analysis of load sharing on uncovertebral and facet joints at the C5-6 level with implantation of the Bryan, Prestige LP, or ProDisc-C cervical disc prosthesis: an in\u00a0vivo image-based finite element study","volume":"28","author":"Kang","year":"2010","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.spinee.2014.03.001_bib17","series-title":"Effects of implant design parameters on cervical disc arthroplasty performance and sagittal balance\u2014a finite element investigation","author":"Kulkarni","year":"2010"},{"key":"10.1016\/j.spinee.2014.03.001_bib18","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.medengphy.2010.02.009","article-title":"Influence of surgical treatment for disc degeneration disease at C5-C6 on changes in some biomechanical parameters of the cervical spine","volume":"32","author":"Li","year":"2010","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2014.03.001_bib19","series-title":"Predictive finite element modeling of artificial cervical discs in a ligamentous functional spinal unit","author":"Bhattacharya","year":"2011"},{"key":"10.1016\/j.spinee.2014.03.001_bib20","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.spinee.2011.06.008","article-title":"Models that incorporate spinal structures predict better wear performance of cervical artificial discs","volume":"11","author":"Bhattacharya","year":"2011","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2014.03.001_bib21","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.clinbiomech.2011.09.014","article-title":"Adjacent level effects of bi level disc replacement, bi level fusion and disc replacement plus fusion in cervical spine\u2014a finite element based study","volume":"27","author":"Faizan","year":"2012","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.spinee.2014.03.001_bib22","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1080\/10255842.2011.597351","article-title":"Biomechanical analysis of the anterior cervical fusion","volume":"15","author":"Fernandes","year":"2012","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"10.1016\/j.spinee.2014.03.001_bib23","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/BRS.0b013e3181f5cb87","article-title":"Comparison of cervical spine biomechanics after fixed- and mobile-core artificial disc replacement: a finite element analysis","volume":"36","author":"Lee","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib24","doi-asserted-by":"crossref","first-page":"E1126","DOI":"10.1097\/BRS.0b013e31820e3dd1","article-title":"Finite element modeling of kinematic and load transmission alterations due to cervical intervertebral disc replacement","volume":"36","author":"Womack","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib25","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1097\/BSD.0b013e318246b163","article-title":"Finite element analysis of cervical arthroplasty combined with fusion against 2-level fusion","volume":"26","author":"Zhao","year":"2013","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2014.03.001_bib26","unstructured":"Gayzik FS. Completion of phase 1 development of the global human body consortium mid-sized male full body finite element model. SAE Government Industry Meeting: Society of Automotive Engineers;\u00a0Warrendale, PA:\u00a02012."},{"key":"10.1016\/j.spinee.2014.03.001_bib27","unstructured":"Stitzel JD. Global human body models consortium (GHBMC) male 50th percentile (M50) occupant model manual. Virginia Tech-Wake Forest University Center for Injury Biomechanics, December 19, 2011. Report No.: GHBMC-FBM-Manual-01. Virginia Tech-Wake Forest University Center for Injury Biomechanics; Winston-Salem, NC."},{"key":"10.1016\/j.spinee.2014.03.001_bib28","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.jmbbm.2012.02.015","article-title":"Cervical spine segment finite element model for traumatic injury prediction","volume":"10","author":"DeWit","year":"2012","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.spinee.2014.03.001_bib29","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.jbiomech.2012.01.016","article-title":"Investigation of whiplash injuries in the upper cervical spine using a detailed neck model","volume":"45","author":"Fice","year":"2012","journal-title":"J Biomech"},{"key":"10.1016\/j.spinee.2014.03.001_bib30","doi-asserted-by":"crossref","first-page":"2152","DOI":"10.1007\/s10439-011-0315-4","article-title":"Cervical spine model to predict capsular ligament response in rear impact","volume":"39","author":"Fice","year":"2011","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.spinee.2014.03.001_bib31","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jmbbm.2012.02.004","article-title":"Strain rate dependent properties of younger human cervical spine ligaments","volume":"10","author":"Mattucci","year":"2012","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.spinee.2014.03.001_bib32","unstructured":"Gayzik FS, Moreno DP, Vavalle NA, et\u00a0al. Development of a full human body finite element model for blunt injury prediction utilizing a multi-modality medical imaging protocol. 12th International LS-DYNA User Conference, Dearborn, MI, USA.\u00a02012."},{"key":"10.1016\/j.spinee.2014.03.001_bib33","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1080\/15389588.2013.799278","article-title":"Validation of simulated chestband data in frontal and lateral loading using a human body finite element model","volume":"15","author":"Hayes","year":"2014","journal-title":"Traffic Inj Prev"},{"issue":"Suppl","key":"10.1016\/j.spinee.2014.03.001_bib34","doi-asserted-by":"crossref","first-page":"S87","DOI":"10.1080\/15389588.2013.802777","article-title":"An evaluation of objective rating methods for full-body finite element model comparison to PMHS tests","volume":"14","author":"Vavalle","year":"2013","journal-title":"Traffic Inj Prev"},{"key":"10.1016\/j.spinee.2014.03.001_bib35","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1007\/s10439-012-0684-3","article-title":"Lateral impact validation of a geometrically accurate full body finite element model for blunt injury prediction","volume":"41","author":"Vavalle","year":"2013","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.spinee.2014.03.001_bib36","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1016\/j.medengphy.2011.05.004","article-title":"Cervical spine response in frontal crash","volume":"33","author":"Panzer","year":"2011","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2014.03.001_bib37","unstructured":"DIN ISO 5834\u20135842:2007-12. Implants for surgery: ultra-high-molecular-weight-polyethylene, part 2: moulded forms (iso 5834-2:2006). Berlin, Germany,\u00a02007."},{"key":"10.1016\/j.spinee.2014.03.001_bib38","unstructured":"eFunda. Ti-6al-4v. Sunnyvale, CA. Available at: http:\/\/www.efunda.com\/materials\/alloys\/titanium\/show_titanium.cfm?ID=T18_AB&prop=all&Page_Title=Ti-6Al-4V. Accessed April 8,\u00a02013."},{"key":"10.1016\/j.spinee.2014.03.001_bib39","unstructured":"eFunda. Aisi type 316l. Sunnyvale, CA. Available at: http:\/\/www.efunda.com\/materials\/alloys\/stainless_steels\/show_stainless.cfm?ID=AISI_Type_316L&show_prop=all&Page_Title=AISI%20Type%20316L. Accessed April 8,\u00a02013."},{"key":"10.1016\/j.spinee.2014.03.001_bib40","doi-asserted-by":"crossref","first-page":"1802","DOI":"10.1016\/j.compscitech.2006.10.020","article-title":"Novel high performance Al2O3\/poly(ether ether ketone) nanocomposites for electronics applications","volume":"67","author":"Goyal","year":"2007","journal-title":"Compos Sci Technol"},{"key":"10.1016\/j.spinee.2014.03.001_bib41","series-title":"Motion preservation surgery of the spine: advanced techniques and controversies","first-page":"52","article-title":"Material properties and wear analysis","author":"Hallab","year":"2008"},{"key":"10.1016\/j.spinee.2014.03.001_bib42","series-title":"Materials and coatings for medical devices\u2014cardiovascular","year":"2009"},{"key":"10.1016\/j.spinee.2014.03.001_bib43","first-page":"299","article-title":"Whole-body kinematic and dynamic response of restrained PMHS in frontal sled tests","volume":"50","author":"Forman","year":"2006","journal-title":"Stapp Car Crash J"},{"key":"10.1016\/j.spinee.2014.03.001_bib44","doi-asserted-by":"crossref","DOI":"10.1080\/10255842.2013.792918","article-title":"Cross-sectional neck response of a total human body FE model during simulated frontal and side automobile impacts","author":"White","year":"2013","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"10.1016\/j.spinee.2014.03.001_bib45","unstructured":"Society of Automotive Engineers. Sae j211\/1. Instrumentation for impact test\u2014part 1. Electronic instrumentation.\u00a0Atlantic City, NJ: October 29 \u2013 November 1, 2007."},{"key":"10.1016\/j.spinee.2014.03.001_bib46","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1002\/nme.1054","article-title":"A spectral-element method for modelling cavitation in transient fluid\u2013structure interaction","volume":"60","author":"Sprague","year":"2004","journal-title":"Int J Numer Methods Eng"},{"key":"10.1016\/j.spinee.2014.03.001_bib47","unstructured":"Mongiardini M, Ray M, Anghileri M. Development of a software for the comparison of curves during the verification and validation of numerical models. 7th European LS-DYNA Conference; Milan, Italy: DYNAmore GmbH;\u00a02009."},{"key":"10.1016\/j.spinee.2014.03.001_bib48","unstructured":"Moorcroft D. Selection of validation metrics for aviation seat models. The Fifth Triennial International Aviation Fire and Cabin Safety Research Conference;\u00a02007."},{"key":"10.1016\/j.spinee.2014.03.001_bib49","first-page":"155","article-title":"Biomechanical and scaling bases for frontal and side impact injury assessment reference values","volume":"47","author":"Mertz","year":"2003","journal-title":"Stapp Car Crash J"},{"key":"10.1016\/j.spinee.2014.03.001_bib50","doi-asserted-by":"crossref","first-page":"2325","DOI":"10.1016\/j.jbiomech.2012.07.015","article-title":"The failure response of the human cervical facet capsular ligament during facet joint retraction","volume":"45","author":"Lee","year":"2012","journal-title":"J Biomech"},{"key":"10.1016\/j.spinee.2014.03.001_bib51","doi-asserted-by":"crossref","first-page":"E7","DOI":"10.3171\/foc.2004.17.3.7","article-title":"In\u00a0vitro biomechanics of cervical disc arthroplasty with the ProDisc-C total disc implant","volume":"17","author":"DiAngelo","year":"2004","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.spinee.2014.03.001_bib52","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/00024720-200308000-00002","article-title":"Biomechanical testing of an artificial cervical joint and an anterior cervical plate","volume":"16","author":"DiAngelo","year":"2003","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2014.03.001_bib53","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3171\/SPI-07\/07\/033","article-title":"Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion","volume":"7","author":"Chang","year":"2007","journal-title":"J Neurosurg Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib54","doi-asserted-by":"crossref","first-page":"E84","DOI":"10.1097\/BRS.0b013e31827b8a2d","article-title":"Prodisc cervical arthroplasty does not alter facet joint contact pressure during lateral bending or axial torsion","volume":"38","author":"Jaumard","year":"2013","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.03.001_bib55","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.spinee.2012.08.013","article-title":"Facet joint contact pressure is not significantly affected by prodisc cervical disc arthroplasty in sagittal bending: a single-level cadaveric study","volume":"12","author":"Bauman","year":"2012","journal-title":"Spine J"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S152994301400240X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S152994301400240X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,6]],"date-time":"2018-10-06T02:27:01Z","timestamp":1538792821000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S152994301400240X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":55,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2014,9]]}},"alternative-id":["S152994301400240X"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2014.03.001","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2014,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effects of cervical arthrodesis and arthroplasty on neck response during a simulated frontal automobile collision","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2014.03.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}