{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T20:43:36Z","timestamp":1765485816790,"version":"3.40.5"},"reference-count":16,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T00:00:00Z","timestamp":1417392000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2014,12]]},"DOI":"10.1016\/j.spinee.2014.07.007","type":"journal-article","created":{"date-parts":[[2014,7,23]],"date-time":"2014-07-23T22:16:36Z","timestamp":1406153796000},"page":"3025-3029","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Kirschner wire-guided technique for inserting a second needle into inadequately filled vertebrae in vertebroplasty: a technical report"],"prefix":"10.1016","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6340-3200","authenticated-orcid":false,"given":"Yen-Jen","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui-Yi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Fu","family":"Lo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hsien-Te","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Horng-Chaung","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2014.07.007_bib1","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1007\/s00402-010-1236-7","article-title":"Repeated percutaneous vertebroplasty for refracture of cemented vertebrae","volume":"131","author":"Chen","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.spinee.2014.07.007_bib2","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1016\/j.ejrad.2011.02.034","article-title":"Repeat needle insertion in vertebroplasty to prevent re-collapse of the treated vertebrae","volume":"81","author":"Chen","year":"2012","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.spinee.2014.07.007_bib3","doi-asserted-by":"crossref","first-page":"94","DOI":"10.3344\/kjp.2013.26.1.94","article-title":"Repeat vertebroplasty for the subsequent refracture of procedured vertebra","volume":"26","author":"Choi","year":"2013","journal-title":"Korean J Pain"},{"key":"10.1016\/j.spinee.2014.07.007_bib4","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1097\/00007632-199708150-00024","article-title":"Idiopathic avascular necrosis of a vertebral body. Case report and literature review","volume":"22","author":"Chou","year":"1997","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.07.007_bib5","first-page":"1657","article-title":"The therapeutic benefit of repeat percutaneous vertebroplasty at previously treated vertebral levels","volume":"23","author":"Gaughen","year":"2002","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.spinee.2014.07.007_bib6","doi-asserted-by":"crossref","first-page":"E585","DOI":"10.1097\/01.brs.0000182226.56498.55","article-title":"Histopathologic findings of retrieved specimens of vertebroplasty with polymethylmethacrylate cement: case control study","volume":"30","author":"Huang","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.07.007_bib7","doi-asserted-by":"crossref","first-page":"270","DOI":"10.3171\/spi.2006.4.3.270","article-title":"Repeated fracture of a vertebral body after treatment with balloon kyphoplasty: case illustration","volume":"4","author":"Leslie-Mazwi","year":"2006","journal-title":"J Neurosurg Spine"},{"issue":"2 Suppl","key":"10.1016\/j.spinee.2014.07.007_bib8","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1177\/15910199080140S215","article-title":"Repeat percutaneous vertebroplasty at cemented vertebra with fluid sign and recurrent pain","volume":"14","author":"Lin","year":"2008","journal-title":"Interv Neuroradiol"},{"key":"10.1016\/j.spinee.2014.07.007_bib9","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1007\/s00586-007-0564-y","article-title":"Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis","volume":"17","author":"Lin","year":"2008","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2014.07.007_bib10","doi-asserted-by":"crossref","first-page":"E457","DOI":"10.1097\/01.BRS.0000096668.54378.25","article-title":"Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: a case report","volume":"28","author":"Tsai","year":"2003","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.07.007_bib11","first-page":"230","article-title":"Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft","volume":"27","author":"Wagner","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.spinee.2014.07.007_bib12","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1097\/BRS.0b013e318166955f","article-title":"Repeat vertebroplasty for unrelieved pain at previously treated vertebral levels with osteoporotic vertebral compression fractures","volume":"33","author":"He","year":"2008","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.07.007_bib13","first-page":"1897","article-title":"Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects","volume":"18","author":"Jensen","year":"1997","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.spinee.2014.07.007_bib14","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1097\/00007632-200107150-00007","article-title":"The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2014.07.007_bib15","doi-asserted-by":"crossref","first-page":"E245","DOI":"10.1097\/BSD.0b013e31825ef90f","article-title":"Clinical evaluation of repeat percutaneous vertebroplasty for symptomatic cemented vertebrae","volume":"25","author":"Chiu","year":"2012","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2014.07.007_bib16","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.2214\/ajr.180.5.1801411","article-title":"Percutaneous vertebroplasty: treatment of painful vertebral compression fractures with intraosseous vacuum phenomena","volume":"180","author":"Peh","year":"2003","journal-title":"AJR Am J Roentgenol"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943014006925?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943014006925?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,8,12]],"date-time":"2019-08-12T23:57:51Z","timestamp":1565654271000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943014006925"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12]]},"references-count":16,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["S1529943014006925"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2014.07.007","relation":{},"ISSN":["1529-9430"],"issn-type":[{"type":"print","value":"1529-9430"}],"subject":[],"published":{"date-parts":[[2014,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Kirschner wire-guided technique for inserting a second needle into inadequately filled vertebrae in vertebroplasty: a technical report","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2014.07.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}