{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T04:37:12Z","timestamp":1782448632964,"version":"3.54.5"},"reference-count":26,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2016,11,1]],"date-time":"2016-11-01T00:00:00Z","timestamp":1477958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,8,3]],"date-time":"2016-08-03T00:00:00Z","timestamp":1470182400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"BioAlpha Incorporation"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2016,11]]},"DOI":"10.1016\/j.spinee.2016.07.531","type":"journal-article","created":{"date-parts":[[2016,8,4]],"date-time":"2016-08-04T12:35:36Z","timestamp":1470314136000},"page":"1367-1376","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":44,"title":["Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion"],"prefix":"10.1016","volume":"16","author":[{"given":"Jae Hyup","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang-Bae","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Jun","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hee-Jong","family":"Shim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki-Hyoung","family":"Koo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeehyoung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Choon-Ki","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bong-Soon","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2016.07.531_bib0010","first-page":"259","article-title":"In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices","volume":"93","author":"Kanayama","year":"2000","journal-title":"J Neurosurg"},{"key":"10.1016\/j.spinee.2016.07.531_bib0015","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1097\/01.brs.0000172160.78207.49","article-title":"Analysis of stress distribution in lumbar interbody fusion","volume":"30","author":"Kumar","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.07.531_bib0020","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/00002517-200002000-00012","article-title":"The biomechanical significance of anterior column support in a simulated single-level spinal fusion","volume":"13","author":"Polly","year":"2000","journal-title":"J Spinal Disord"},{"key":"10.1016\/j.spinee.2016.07.531_bib0025","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/S1529-9430(03)00004-4","article-title":"Intervertebral cages for degenerative spinal diseases","volume":"3","author":"Blumenthal","year":"2003","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2016.07.531_bib0030","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1002\/jbm.820240306","article-title":"Ca,P-rich layer formed on high-strength bioactive glass-ceramic A-W","volume":"24","author":"Kokubo","year":"1990","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.spinee.2016.07.531_bib0035","doi-asserted-by":"crossref","DOI":"10.1098\/rsif.2008.0419.focus","article-title":"Bioactive ceramic-based materials with designed reactivity for bone tissue regeneration","volume":"6","author":"Ohtsuki","year":"2009","journal-title":"J R Soc Interface"},{"key":"10.1016\/j.spinee.2016.07.531_bib0040","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1007\/s10856-006-0432-z","article-title":"The story of Bioglass","volume":"17","author":"Hench","year":"2006","journal-title":"J Mater Sci Mater Med"},{"key":"10.1016\/j.spinee.2016.07.531_bib0045","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1002\/jbm.820251105","article-title":"Apatite formation on the surface of Ceravital-type glass-ceramic in the body","volume":"25","author":"Ohtsuki","year":"1991","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.spinee.2016.07.531_bib0050","first-page":"541","article-title":"Research and development of A-W bioactive glass ceramic","volume":"20","author":"Yang","year":"2003","journal-title":"Sheng Wu Yi Xue Gong Cheng Xue Za Zhi"},{"key":"10.1016\/j.spinee.2016.07.531_bib0055","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1111\/aor.12027","article-title":"Fabrication and evaluation of osteoblastic differentiation of human mesenchymal stem cells on novel CaO-SiO2-P2O5-B2O3 glass-ceramic","volume":"37","author":"Lee","year":"2013","journal-title":"Artif Organs"},{"key":"10.1016\/j.spinee.2016.07.531_bib0060","first-page":"540","article-title":"Quantitative comparison of novel CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) with hydroxyapatite as bone graft extender in rabbit ilium","volume":"7","author":"Lee","year":"2010","journal-title":"Tissue Eng Regen Med"},{"key":"10.1016\/j.spinee.2016.07.531_bib0065","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1007\/s00776-011-0047-1","article-title":"Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone","volume":"16","author":"Lee","year":"2011","journal-title":"J Orthop Sci"},{"key":"10.1016\/j.spinee.2016.07.531_bib0070","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1111\/aor.12040","article-title":"In vivo evaluation of CaO-SiO2-P2O5-B2O3 glass-ceramics coating on Steinman pins","volume":"37","author":"Lee","year":"2013","journal-title":"Artif Organs"},{"key":"10.1016\/j.spinee.2016.07.531_bib0075","doi-asserted-by":"crossref","first-page":"38","DOI":"10.3109\/01480540903373647","article-title":"A 90-day intravenous administration toxicity study of CaO-SiO2-P2O5-B2O3 glass-ceramics (BGS-7) in rat","volume":"33","author":"Lee","year":"2010","journal-title":"Drug Chem Toxicol"},{"key":"10.1016\/j.spinee.2016.07.531_bib0080","first-page":"811","article-title":"Treatment of bone defects in rabbit tibiae using CaO-SiO2-P2O5-B2O3 bioactive ceramics: radiological, biomechanical, and histological evaluation","volume":"6","author":"Koo","year":"2009","journal-title":"Tissue Eng Regen Med"},{"key":"10.1016\/j.spinee.2016.07.531_bib0085","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1111\/aor.12107","article-title":"Finite element modeling of stress distribution in intervertebral spacers of different surface geometries","volume":"37","author":"Lee","year":"2013","journal-title":"Artif Organs"},{"key":"10.1016\/j.spinee.2016.07.531_bib0090","series-title":"Statistical principles for clinical trials E9","author":"ICH Harmonised Tripartite Guideline","year":"1998"},{"key":"10.1016\/j.spinee.2016.07.531_bib0095","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1002\/sim.2561","article-title":"An introductory note to CHMP guideline: choice of the non-inferiority margin and data monitoring committees","volume":"25","author":"Brown","year":"2006","journal-title":"Statist Med"},{"key":"10.1016\/j.spinee.2016.07.531_bib0100","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3928\/0147-7447-19980201-09","article-title":"Comparison of plain radiographs and CT scans in instrumented posterior lumbar interbody fusion","volume":"21","author":"Siambanes","year":"1998","journal-title":"Orthopedics"},{"key":"10.1016\/j.spinee.2016.07.531_bib0105","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.spinee.2013.07.436","article-title":"A comparison of dynamic views using plain radiographs and thin-section three-dimensional computed tomography in the evaluation of fusion after posterior lumbar interbody fusion surgery","volume":"13","author":"Lee","year":"2013","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2016.07.531_bib0110","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1097\/BRS.0b013e3181c4baf5","article-title":"Fusion rates and subsidence of morselized local bone grafted in titanium cages in posterior lumbar interbody fusion using quantitative three-dimensional computed tomography scans","volume":"35","author":"Lee","year":"2010","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.07.531_bib0115","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.spinee.2011.04.029","article-title":"Fusion rates of a morselized local bone graft in polyetheretherketone cages in posterior lumbar interbody fusion by quantitative analysis using consecutive three-dimensional computed tomography scans","volume":"11","author":"Lee","year":"2011","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2016.07.531_bib0120","doi-asserted-by":"crossref","first-page":"12","DOI":"10.4103\/0974-8237.85308","article-title":"Clinico-radiological profile of indirect neural decompression using cage or auto graft as interbody construct in posterior lumbar interbody fusion in spondylolisthesis: which is better?","volume":"2","author":"Abdul","year":"2011","journal-title":"J Craniovertebr Junction Spine"},{"key":"10.1016\/j.spinee.2016.07.531_bib0125","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0030-5898(01)00013-X","article-title":"Advances in posterior lumbar interbody fusion","volume":"33","author":"Brislin","year":"2002","journal-title":"Orthop Clin North Am"},{"key":"10.1016\/j.spinee.2016.07.531_bib0130","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.surneu.2005.03.025","article-title":"Clinical and radiological relationship between posterior lumbar interbody fusion and posterolateral lumbar fusion","volume":"64","author":"Lidar","year":"2005","journal-title":"Surg Neurol"},{"key":"10.1016\/j.spinee.2016.07.531_bib0135","doi-asserted-by":"crossref","first-page":"87","DOI":"10.4055\/cios.2014.6.1.87","article-title":"Negative effect of rapidly resorbing properties of bioactive glass-ceramics as bone graft substitute in a rabbit lumbar fusion model","volume":"6","author":"Lee","year":"2014","journal-title":"Clini Orthop Surg"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943016308282?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943016308282?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,4]],"date-time":"2022-07-04T23:20:35Z","timestamp":1656976835000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943016308282"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["S1529943016308282"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2016.07.531","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of fusion rate and clinical results between CaO-SiO2-P2O5-B2O3 bioactive glass ceramics spacer with titanium cages in posterior lumbar interbody fusion","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2016.07.531","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}