{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T20:04:43Z","timestamp":1786997083455,"version":"build-2736575974"},"reference-count":27,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2017,3,1]],"date-time":"2017-03-01T00:00:00Z","timestamp":1488326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2017,3]]},"DOI":"10.1016\/j.spinee.2016.10.001","type":"journal-article","created":{"date-parts":[[2016,10,9]],"date-time":"2016-10-09T07:31:29Z","timestamp":1475998289000},"page":"328-337","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["Application of cement on strategic vertebrae in the treatment of the osteoporotic spine"],"prefix":"10.1016","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7377-6393","authenticated-orcid":false,"given":"Mehmet Nuri","family":"Erdem","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sinan","family":"Karaca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seckin","family":"Sar\u0131","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feridun","family":"Yumrukcal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruhat","family":"Tanli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4963-8382","authenticated-orcid":false,"given":"Mehmet","family":"Aydogan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2016.10.001_bib0010","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/j.spinee.2009.05.002","article-title":"Spine surgeons survey on attitudes regarding osteoporosis and osteomalacia screening and treatment for fractures, fusion surgery, and pseudoarthrosis","volume":"9","author":"Allen","year":"2009","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2016.10.001_bib0015","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/j.medengphy.2004.12.007","article-title":"Failure analysis of broken pedicle screws on spinal instrumentation","volume":"27","author":"Chen","year":"2005","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2016.10.001_bib0020","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","article-title":"Effects of bone mineral density on pedicle screw fixation","volume":"19","author":"Halvorson","year":"1994","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0025","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1097\/00007632-199705010-00004","article-title":"An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine","volume":"22","author":"Hasegawa","year":"1997","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0030","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1097\/BSD.0b013e31818e0945","article-title":"The pedicle screw fixation with vertebroplasty augmentation in the surgical treatment of the severe osteoporotic spines","volume":"22","author":"Aydogan","year":"2009","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2016.10.001_bib0035","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0b013e31816f6c73","article-title":"Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique","volume":"33","author":"Chang","year":"2008","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0040","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1097\/01.brs.0000261566.38422.40","article-title":"Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength","volume":"32","author":"Burval","year":"2007","journal-title":"Spine"},{"issue":"Suppl. 6","key":"10.1016\/j.spinee.2016.10.001_bib0045","doi-asserted-by":"crossref","first-page":"S196","DOI":"10.1097\/00007632-199206001-00023","article-title":"Screw fixation in the human sacrum. An in vitro study of the biomechanics of fixation","volume":"17","author":"Carlson","year":"1992","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0050","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1097\/00007632-199405001-00012","article-title":"Pedicle screws and bone mineral density","volume":"19","author":"Kumano","year":"1994","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0055","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1097\/00007632-199708010-00003","article-title":"Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement","volume":"22","author":"Moore","year":"1997","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0060","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","article-title":"An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine","volume":"16","author":"Soshi","year":"1991","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0065","first-page":"278","article-title":"Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength","author":"Wittenberg","year":"1993","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.spinee.2016.10.001_bib0070","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1007\/s00586-008-0615-z","article-title":"Short fusion versus long fusion for degenerative lumbar scoliosis","volume":"17","author":"Cho","year":"2008","journal-title":"Eur Spine J"},{"issue":"Suppl. 2","key":"10.1016\/j.spinee.2016.10.001_bib0075","first-page":"163","article-title":"Risk factors for adjacent segment failure following lumbar fixation with rigid instrumentation for degenerative instability","volume":"90","author":"Etebar","year":"1999","journal-title":"J Neurosurg"},{"key":"10.1016\/j.spinee.2016.10.001_bib0080","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1097\/01.brs.0000238969.59928.73","article-title":"Sagittal thoracic decompensation following long adult spinal instrumentation and fusion to L5 or S1: causes, prevalence, and risk factor analysis","volume":"31","author":"Kim","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0085","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1097\/BSD.0b013e31818d6493","article-title":"Bone cement augmentation in the prevention of adjacent segment failure after multilevel adult deformity fusion","volume":"22","author":"Lattig","year":"2009","journal-title":"J Spinal Disord Tech"},{"issue":"Suppl. 3","key":"10.1016\/j.spinee.2016.10.001_bib0090","first-page":"309","article-title":"Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines","volume":"96","author":"Sarzier","year":"2002","journal-title":"J Neurosurg"},{"key":"10.1016\/j.spinee.2016.10.001_bib0095","first-page":"99","article-title":"A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine","author":"Zindrick","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.spinee.2016.10.001_bib0100","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1097\/00007632-199808010-00008","article-title":"Revision of failed pedicle screws using hydroxyapatite cement: a biomechanical analysis","volume":"23","author":"Yerby","year":"1998","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2016.10.001_bib0105","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/BSD.0b013e318246ae8a","article-title":"Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method","volume":"26","author":"Chang","year":"2013","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2016.10.001_bib0110","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1007\/s00586-004-0839-5","article-title":"Cement leakage during vertebroplasty: an underestimated problem?","volume":"14","author":"Schmidt","year":"2005","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2016.10.001_bib0115","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1302\/0301-620X.76B1.8300663","article-title":"Neurological deterioration after cement injection into a vertebral body","volume":"76","author":"Wilkes","year":"1994","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.spinee.2016.10.001_bib0120","first-page":"262","article-title":"Treatment of painful compression vertebral fractures with vertebroplasty: results and complications","volume":"110","author":"Anselmetti","year":"2005","journal-title":"Radiol Med"},{"key":"10.1016\/j.spinee.2016.10.001_bib0125","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.2214\/ajr.183.4.1831097","article-title":"Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty","volume":"183","author":"Choe","year":"2004","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.spinee.2016.10.001_bib0130","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1080\/02841850701422153","article-title":"Pulmonary cement embolism: a complication of percutaneous vertebroplasty","volume":"48","author":"Duran","year":"2007","journal-title":"Acta Radiol"},{"key":"10.1016\/j.spinee.2016.10.001_bib0135","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1148\/radiol.2511080854","article-title":"Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors","volume":"251","author":"Kim","year":"2009","journal-title":"Radiology"},{"key":"10.1016\/j.spinee.2016.10.001_bib0140","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1097\/00007632-200203010-00005","article-title":"Fat embolism and acute hypotension during vertebroplasty: an experimental study in sheep","volume":"27","author":"Aebli","year":"2002","journal-title":"Spine"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943016310014?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943016310014?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,9,14]],"date-time":"2019-09-14T07:46:06Z","timestamp":1568447166000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943016310014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,3]]}},"alternative-id":["S1529943016310014"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2016.10.001","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2017,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Application of cement on strategic vertebrae in the treatment of the osteoporotic spine","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2016.10.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}