{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T20:14:58Z","timestamp":1793391298099,"version":"4.5.0"},"reference-count":57,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2017,8,1]],"date-time":"2017-08-01T00:00:00Z","timestamp":1501545600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2017,8]]},"DOI":"10.1016\/j.spinee.2017.04.029","type":"journal-article","created":{"date-parts":[[2017,6,10]],"date-time":"2017-06-10T09:47:56Z","timestamp":1497088076000},"page":"1192-1199","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":52,"title":["Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality"],"prefix":"10.1016","volume":"17","author":[{"given":"M.","family":"Mart\u00edn-Fern\u00e1ndez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"L\u00f3pez-Herrad\u00f3n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.R.","family":"Pi\u00f1era","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Tom\u00e9-Bermejo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.M.","family":"Duart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.D.","family":"Vlad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.G.","family":"Rodr\u00edguez-Arguisjuela","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Alvarez-Galovich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"Suppl. 4","key":"10.1016\/j.spinee.2017.04.029_bib0010","doi-asserted-by":"crossref","first-page":"S68","DOI":"10.1227\/NEU.0000000000000943","article-title":"Management of degenerative lumbar spinal stenosis in the elderly","volume":"77","author":"Shamji","year":"2015","journal-title":"Neurosurgery"},{"issue":"Suppl. 4","key":"10.1016\/j.spinee.2017.04.029_bib0015","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.1227\/NEU.0000000000000949","article-title":"A cost-utility analysis of lumbar decompression with and without fusion for degenerative spine disease in the elderly","volume":"77","author":"Devin","year":"2015","journal-title":"Neurosurgery"},{"key":"10.1016\/j.spinee.2017.04.029_bib0020","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1007\/s00586-015-4078-8","article-title":"Predictors of improvement in quality of life and pain relief in lumbar spinal stenosis relative to patient age: a study based on the Spine Tango registry","volume":"26","author":"Sobottke","year":"2017","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0025","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1007\/s00198-007-0515-9","article-title":"Influence of osteoporosis on fracture fixation\u2014a systematic literature review","volume":"19","author":"Goldhahn","year":"2008","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.spinee.2017.04.029_bib0030","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","article-title":"Effects of bone mineral density on pedicle screw fixation","volume":"19","author":"Halvorson","year":"1994","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0035","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/00007632-199106000-00009","article-title":"Importance of bone mineral density in instrumented spine fusions","volume":"16","author":"Wittenberg","year":"1991","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0040","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1097\/00007632-199203001-00011","article-title":"Mechanical stability of the pedicle screw fixation systems for the lumbar spine","volume":"17","author":"Yamagata","year":"1992","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0045","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1097\/00007632-199312000-00012","article-title":"Caudo-cephalad loading of pedicle screws: mechanisms of loosening and methods of augmentation","volume":"18","author":"Law","year":"1993","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0050","doi-asserted-by":"crossref","first-page":"198","DOI":"10.3113\/JSOA.2012.0198","article-title":"A biomechanical study of two different pedicle screw methods for fixation in osteoporotic and nonosteoporotic vertebrae","volume":"21","author":"Higashino","year":"2012","journal-title":"J Surg Orthop Adv"},{"key":"10.1016\/j.spinee.2017.04.029_bib0055","first-page":"23","article-title":"Pedicle screw fixation strength: a biomechanical comparison between 4.5-mm and 5.5-mm diameter screws in osteoporotic upper thoracic vertebrae","volume":"18","author":"Tsai","year":"2009","journal-title":"J Surg Orthop Adv"},{"issue":"26 Spec No.","key":"10.1016\/j.spinee.2017.04.029_bib0060","doi-asserted-by":"crossref","first-page":"B27","DOI":"10.1097\/BRS.0000000000000431","article-title":"Krag versus Caudad trajectory technique for pedicle screw insertion in osteoporotic vertebrae: biomechanical comparison and analysis","volume":"39","author":"Yuan","year":"2014","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0065","article-title":"Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status","volume":"748393","author":"Shea","year":"2014","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.spinee.2017.04.029_bib0070","article-title":"Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading","volume":"27","author":"Bostelmann","year":"2015","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0075","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1016\/j.spinee.2015.03.016","article-title":"The biomechanics of pedicle screw augmentation with cement","volume":"15","author":"Elder","year":"2015","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0080","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/BSD.0b013e31819942cd","article-title":"Pedicle screw augmentation with polyethylene tape: a biomechanical study in the osteoporotic thoracolumbar spine","volume":"23","author":"Hamasaki","year":"2010","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2017.04.029_bib0085","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.medengphy.2013.04.007","article-title":"Biomechanical analysis of different types of pedicle screw augmentation: a cadaveric and synthetic bone sample study of instrumented vertebral specimens","volume":"35","author":"Chao","year":"2013","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2017.04.029_bib0090","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","article-title":"Assessment of different screw augmentation techniques and screw designs in osteoporotic spines","volume":"17","author":"Becker","year":"2008","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0095","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1016\/j.medengphy.2014.05.003","article-title":"Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws","volume":"36","author":"Chen","year":"2014","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.spinee.2017.04.029_bib0100","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/j.spinee.2011.06.006","article-title":"A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws","volume":"11","author":"Vishnubhotla","year":"2011","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0105","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","article-title":"Cortical bone trajectory for lumbar pedicle screws","volume":"9","author":"Santoni","year":"2009","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0110","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s13013-015-0039-6","article-title":"Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw","volume":"10","author":"Christodoulou","year":"2015","journal-title":"Scoliosis"},{"key":"10.1016\/j.spinee.2017.04.029_bib0115","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.spinee.2003.11.010","article-title":"Biomechanical study of pedicle screw fixation in severely osteoporotic bone","volume":"4","author":"Cook","year":"2004","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0120","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00007632-199402000-00017","article-title":"Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction","volume":"19","author":"Pfeifer","year":"1994","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0125","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","article-title":"An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine","volume":"16","author":"Soshi","year":"1991","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0130","doi-asserted-by":"crossref","first-page":"E478","DOI":"10.1097\/BRS.0b013e3181a8f663","article-title":"Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device","volume":"34","author":"Waits","year":"2009","journal-title":"Spine"},{"issue":"Suppl. 3","key":"10.1016\/j.spinee.2017.04.029_bib0135","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1007\/s00586-011-1907-2","article-title":"Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentation","volume":"20","author":"Pi\u00f1era","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0140","doi-asserted-by":"crossref","first-page":"305","DOI":"10.3340\/jkns.2009.46.4.305","article-title":"Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients","volume":"46","author":"Moon","year":"2009","journal-title":"J Korean Neurosurg Soc"},{"key":"10.1016\/j.spinee.2017.04.029_bib0145","doi-asserted-by":"crossref","first-page":"E28","DOI":"10.1097\/BSD.0b013e318228bbed","article-title":"Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients","volume":"25","author":"Sawakami","year":"2012","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2017.04.029_bib0150","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s00586-013-3131-8","article-title":"Clinical evaluation of the polymethylmethacrylate-augmented thoracic and lumbar pedicle screw fixation guided by the three-dimensional navigation for the osteoporosis patients","volume":"24","author":"Yuan","year":"2015","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0155","first-page":"269","article-title":"Pulmonary cement embolism after augmentation of pedicle screws with bone cement","volume":"76","author":"R\u00f6llinghoff","year":"2010","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.spinee.2017.04.029_bib0160","doi-asserted-by":"crossref","first-page":"1983","DOI":"10.1097\/01.brs.0000229254.89952.6b","article-title":"Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies","volume":"31","author":"Hulme","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0165","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1007\/s00586-004-0839-5","article-title":"Cement leakage during vertebroplasty: an underestimated problem?","volume":"14","author":"Schmidt","year":"2005","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0170","doi-asserted-by":"crossref","first-page":"2395","DOI":"10.1097\/BRS.0b013e3181b8707e","article-title":"The value of routinely performing a bone biopsy during percutaneous vertebroplasty in treatment of osteoporotic vertebral compression fractures","volume":"34","author":"Muijs","year":"2009","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0175","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1097\/01.brs.0000216487.97965.38","article-title":"Percutaneous vertebroplasty: functional improvement in patients with osteoporotic compression fractures","volume":"31","author":"\u00c1lvarez","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0180","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00007632-200501010-00016","article-title":"Predictors of outcomes of percutaneous vertebroplasty for osteoporotic vertebral fractures","volume":"30","author":"\u00c1lvarez","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0185","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","article-title":"Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures","volume":"85","author":"Yeom","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.spinee.2017.04.029_bib0190","doi-asserted-by":"crossref","first-page":"61","DOI":"10.3171\/2013.4.SPINE12978","article-title":"Neurological deficit due to cement extravasation following a vertebral augmentation procedure","volume":"19","author":"Sidhu","year":"2013","journal-title":"J Neurosurg Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0195","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1016\/j.spinee.2013.09.025","article-title":"Basivertebral foramen could be connected with intravertebral cleft: a potential risk factor of cement leakage in percutaneous kyphoplasty","volume":"14","author":"Wang","year":"2014","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0200","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.spinee.2013.02.072","article-title":"Trabecular bone structure in lumbosacral transitional vertebrae: distribution and densities across sagittal vertebral body segments","volume":"13","author":"Mahato","year":"2013","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0205","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/BRS.0000000000000294","article-title":"Identification of risk factors for the occurrence of cement leakage during percutaneous vertebroplasty for painful osteoporotic or malignant vertebral fracture","volume":"39","author":"Tom\u00e9-Bermejo","year":"2014","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0210","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1007\/s00586-011-1824-4","article-title":"Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body","volume":"20","author":"Hu","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0215","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.clineuro.2014.11.018","article-title":"Comparison of high viscosity bone cement and low viscosity bone cement vertebroplasty for severe osteoporotic vertebral compression fractures","volume":"129","author":"Zhang","year":"2015","journal-title":"Clin Neurol Neurosurg"},{"issue":"Suppl. 1","key":"10.1016\/j.spinee.2017.04.029_bib0220","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.1007\/s00586-012-2221-3","article-title":"Cement leakage: safety of minimally invasive surgical techniques in the treatment of multiple myeloma vertebral lesions","volume":"21","author":"La Maida","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0225","doi-asserted-by":"crossref","first-page":"3450","DOI":"10.1007\/s00586-015-3920-3","article-title":"Reduction of cement leakage by sequential PMMA application in a vertebroplasty model","volume":"25","author":"Hoppe","year":"2016","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0230","first-page":"269","article-title":"Pulmonary cement embolism after augmentation of pedicle screws with bone cement","volume":"76","author":"R\u00f6llinghoff","year":"2010","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.spinee.2017.04.029_bib0235","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.spinee.2013.05.053","article-title":"Infection after vertebroplasty or kyphoplasty. A series of nine cases and review of literature","volume":"13","author":"Abdelrahman","year":"2013","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0240","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1016\/j.spinee.2015.01.030","article-title":"Intrasite vancomycin powder for the prevention of surgical site infection in spine surgery: a systematic literature review","volume":"15","author":"Kang","year":"2015","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0245","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1007\/s00586-012-2514-6","article-title":"A methodological, systematic review of evidence-based independent risk factors for surgical site infections after spinal surgery","volume":"22","author":"Xing","year":"2013","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0250","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1007\/s00586-007-0473-0","article-title":"Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement","volume":"16","author":"Boger","year":"2007","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0255","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1097\/00007632-200005010-00004","article-title":"Biomechanical evaluation of a new bone cement for use in vertebroplasty","volume":"25","author":"Belkoff","year":"2000","journal-title":"Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0260","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1007\/s00586-011-2119-5","article-title":"The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty","volume":"21","author":"Kinzl","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0265","doi-asserted-by":"crossref","first-page":"2092","DOI":"10.1097\/01.brs.0000435029.88434.97","article-title":"Does bone cement in percutaneous vertebroplasty act as a stress riser?","volume":"38","author":"Aquarius","year":"2013","journal-title":"Spine"},{"issue":"Suppl. 6","key":"10.1016\/j.spinee.2017.04.029_bib0270","doi-asserted-by":"crossref","first-page":"S792","DOI":"10.1007\/s00586-011-1989-x","article-title":"Safety, effectiveness and predictors for early reoperation in therapeutic and prophylactic vertebroplasty: short-term results of a prospective case series of patients with osteoporotic vertebral fractures","volume":"21","author":"Diel","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2017.04.029_bib0275","doi-asserted-by":"crossref","first-page":"79","DOI":"10.14245\/kjs.2012.9.2.79","article-title":"Clinical efficacy of bone cement augmented screw fixation for the severe osteoporotic spine","volume":"9","author":"Seo","year":"2012","journal-title":"Korean J Spine"},{"key":"10.1016\/j.spinee.2017.04.029_bib0285","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/BSD.0b013e318246ae8a","article-title":"Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method","volume":"26","author":"Chang","year":"2013","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2017.04.029_bib0290","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BSD.0b013e3181f605d0","article-title":"Is it safe to back out pedicle screws after augmentation with polymethyl methacrylate or calcium phosphate cement? A biomechanical study","volume":"24","author":"Cho","year":"2011","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.spinee.2017.04.029_bib0295","doi-asserted-by":"crossref","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","article-title":"Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers","volume":"35","author":"Bullmann","year":"2010","journal-title":"Spine"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943017301869?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943017301869?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:57:48Z","timestamp":1535763468000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943017301869"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":57,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017,8]]}},"alternative-id":["S1529943017301869"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2017.04.029","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2017.04.029","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}