{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:41:29Z","timestamp":1792784489946,"version":"4.5.0"},"reference-count":46,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T00:00:00Z","timestamp":1601337600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Neo Medical"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1016\/j.spinee.2020.09.010","type":"journal-article","created":{"date-parts":[[2020,9,30]],"date-time":"2020-09-30T06:45:03Z","timestamp":1601448303000},"page":"528-537","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":22,"title":["Misaligned spinal rods can induce high internal forces consistent with those observed to cause screw pullout and disc degeneration"],"prefix":"10.1016","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7306-0758","authenticated-orcid":false,"given":"Arjan C.Y.","family":"Loenen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David C.","family":"Noriega","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Ruiz Wills","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00e9r\u00f4me","family":"Noailly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierce D.","family":"Nunley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rainer","family":"Kirchner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keita","family":"Ito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bert","family":"van Rietbergen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.spinee.2020.09.010_bib0001","series-title":"Spinal disorders: Fundamentals of diagnosis and treatment","first-page":"67","article-title":"Spinal instrumentation","author":"Haschtmann","year":"2008"},{"issue":"10","key":"10.1016\/j.spinee.2020.09.010_bib0002","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1016\/j.spinee.2019.06.019","article-title":"Augmented reality-assisted rod bending in spinal surgery","volume":"19","author":"Wanivenhaus","year":"2019","journal-title":"Spine J"},{"key":"10.1016\/j.spinee.2020.09.010_bib0003","series-title":"Surgery of the spine and spinal cord: a neurosurgical approach","first-page":"645","article-title":"Preoperative planning and patient-specific rods for surgical treatment of thoracolumbar sagittal imbalance","author":"Fiere","year":"2016"},{"issue":"11","key":"10.1016\/j.spinee.2020.09.010_bib0004","doi-asserted-by":"crossref","first-page":"S143","DOI":"10.1016\/j.spinee.2014.08.348","article-title":"Long construct pedicle screw reduction and residual forces are decreased using a computer-assisted spinal rod bending system","volume":"14","author":"Tohmeh","year":"2014","journal-title":"Spine J"},{"issue":"11","key":"10.1016\/j.spinee.2020.09.010_bib0005","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1016\/j.spinee.2013.05.013","article-title":"The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?","volume":"13","author":"Paik","year":"2013","journal-title":"Spine J"},{"issue":"1","key":"10.1016\/j.spinee.2020.09.010_bib0006","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.spinee.2014.07.017","article-title":"Effects of rod reduction on pedicle screw fixation strength in the setting of Ponte osteotomies","volume":"15","author":"Kang","year":"2015","journal-title":"Spine J"},{"issue":"1","key":"10.1016\/j.spinee.2020.09.010_bib0007","doi-asserted-by":"crossref","first-page":"79","DOI":"10.22603\/ssrr.2018-0018","article-title":"Risk factors for clinically relevant loosening of percutaneous pedicle screws","volume":"3","author":"Ohba","year":"2018","journal-title":"Spine Surg Relat Res"},{"issue":"13","key":"10.1016\/j.spinee.2020.09.010_bib0008","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1097\/00007632-200007010-00004","article-title":"The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments","volume":"25","author":"Umehara","year":"2000","journal-title":"Spine"},{"issue":"5","key":"10.1016\/j.spinee.2020.09.010_bib0009","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1243\/09544110260216568","article-title":"Finite element analysis in spine research","volume":"216","author":"Fagan","year":"2002","journal-title":"Proc Inst Mech Eng"},{"key":"10.1016\/j.spinee.2020.09.010_bib0010","series-title":"Biomaterials for spinal surgery","article-title":"5 - Finite element modelling of the spine","author":"Noailly","year":"2012"},{"key":"10.1016\/j.spinee.2020.09.010_bib0011","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3389\/fbioe.2015.00005","article-title":"On the relative relevance of subject-specific geometries and degeneration-specific mechanical properties for the study of cell death in human intervertebral disk models","volume":"3","author":"Malandrino","year":"2015","journal-title":"Front Bioengineer Biotechnol"},{"issue":"8","key":"10.1016\/j.spinee.2020.09.010_bib0012","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0200899","article-title":"Comparison of patient-specific computational models vs. clinical follow-up, for adjacent segment disc degeneration and bone remodelling after spinal fusion","volume":"13","author":"Rijsbergen","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.spinee.2020.09.010_bib0013","series-title":"Recent advances in computational methods and clinical applications for spine imaging","first-page":"241","article-title":"3D vertebra segmentation by feature selection active shape model","author":"Castro-Mateos","year":"2015"},{"issue":"24","key":"10.1016\/j.spinee.2020.09.010_bib0014","doi-asserted-by":"crossref","first-page":"7847","DOI":"10.1088\/0031-9155\/59\/24\/7847","article-title":"3D segmentation of annulus fibrosus and nucleus pulposus from T2-weighted magnetic resonance images","volume":"59","author":"Castro-Mateos","year":"2014","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.spinee.2020.09.010_bib0015","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1006\/cviu.1995.1004","article-title":"Active shape models-their training and application","volume":"61","author":"Cootes","year":"1995","journal-title":"Comput Vision Image Understand"},{"key":"10.1016\/j.spinee.2020.09.010_bib0016","series-title":"Proceedings, Medical Imaging: Biomedical Applications in Molecular, Structural, and Functional Imaging","article-title":"Automatic construction of patient-specific finite-element mesh of the spine from IVDs and vertebra segmentations","volume":"9788","author":"Castro-Mateos","year":"2016"},{"issue":"8","key":"10.1016\/j.spinee.2020.09.010_bib0017","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1007\/s00264-009-0920-0","article-title":"Prevalence of low back pain and lumbar spine degenerative disorders. Questionnaire survey and clinical-radiological analysis of a representative Hungarian population","volume":"34","author":"Horv\u00e1th","year":"2010","journal-title":"Int Orthop"},{"issue":"9","key":"10.1016\/j.spinee.2020.09.010_bib0018","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.2760","article-title":"Patient-specific fracture risk assessment of vertebrae: a multiscale approach coupling x-ray physics and continuum micromechanics","volume":"32","author":"Blanchard","year":"2016","journal-title":"Int J Numer Method Biomed Eng"},{"issue":"4","key":"10.1016\/j.spinee.2020.09.010_bib0019","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.clinbiomech.2006.11.008","article-title":"Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment","volume":"22","author":"Schmidt","year":"2007","journal-title":"Clin Biomech"},{"issue":"7","key":"10.1016\/j.spinee.2020.09.010_bib0020","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.joca.2014.05.005","article-title":"The role of endplate poromechanical properties on the nutrient availability in the intervertebral disc","volume":"22","author":"Malandrino","year":"2014","journal-title":"Osteoarthr Cartil"},{"issue":"9","key":"10.1016\/j.spinee.2020.09.010_bib0021","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1080\/10255842.2011.644539","article-title":"Regional annulus fibre orientations used as a tool for the calibration of lumbar intervertebral disc finite element models","volume":"16","author":"Malandrino","year":"2013","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"17","key":"10.1016\/j.spinee.2020.09.010_bib0022","doi-asserted-by":"crossref","first-page":"1873","DOI":"10.1097\/00007632-200109010-00011","article-title":"Magnetic resonance classification of lumbar intervertebral disc degeneration","volume":"26","author":"Pfirrmann","year":"2001","journal-title":"Spine"},{"issue":"suppl 5","key":"10.1016\/j.spinee.2020.09.010_bib0023","doi-asserted-by":"crossref","first-page":"S675","DOI":"10.1007\/s00586-011-1716-7","article-title":"In silico evaluation of a new composite disc substitute with a L3-L5 lumbar spine finite element model","volume":"21","author":"Noailly","year":"2012","journal-title":"Eur Spine J"},{"issue":"4","key":"10.1016\/j.spinee.2020.09.010_bib0024","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1364\/JOSAA.4.000629","article-title":"Closed-form solution of absolute orientation using unit quaternions","volume":"4","author":"Horn","year":"1987","journal-title":"J Opt Soc Am A"},{"key":"10.1016\/j.spinee.2020.09.010_bib0025","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.jbiomech.2017.11.034","article-title":"Coupled motions in human and porcine thoracic and lumbar spines","volume":"70","author":"Kingma","year":"2018","journal-title":"J Biomech"},{"issue":"7","key":"10.1016\/j.spinee.2020.09.010_bib0026","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1016\/S0021-9290(98)00057-8","article-title":"Yield strain behavior of trabecular bone","volume":"31","author":"Kopperdahl","year":"1998","journal-title":"J Biomech"},{"issue":"1","key":"10.1016\/j.spinee.2020.09.010_bib0027","doi-asserted-by":"crossref","DOI":"10.1186\/ar4449","article-title":"High mechanical strain of primary intervertebral disc cells promotes secretion of inflammatory factors associated with disc degeneration and pain","volume":"16","author":"Gawri","year":"2014","journal-title":"Arthritis Res Ther"},{"issue":"4","key":"10.1016\/j.spinee.2020.09.010_bib0028","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1302\/0301-620X.100B4.BJJ-2017-0877.R1","article-title":"A comparison of the biomechanical stability of pedicle-lengthening screws and traditional pedicle screws","volume":"100-B","author":"Qian","year":"2018","journal-title":"Bone Joint J"},{"issue":"2","key":"10.1016\/j.spinee.2020.09.010_bib0029","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1111\/os.12322","article-title":"Pull out strength of dual outer diameter pedicle screws compared to uncemented and cemented standard pedicle screws: a biomechanical in vitro study","volume":"9","author":"Lorenz","year":"2017","journal-title":"Orthop Surg"},{"issue":"21","key":"10.1016\/j.spinee.2020.09.010_bib0030","doi-asserted-by":"crossref","first-page":"2429","DOI":"10.1097\/00007632-199611010-00004","article-title":"Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone","volume":"21","author":"Kwok","year":"1996","journal-title":"Spine"},{"issue":"3","key":"10.1016\/j.spinee.2020.09.010_bib0031","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2106\/00004623-199403000-00012","article-title":"Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves","volume":"76","author":"Panjabi","year":"1994","journal-title":"J Bone Joint Surg Am Vol"},{"issue":"20","key":"10.1016\/j.spinee.2020.09.010_bib0032","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1097\/00007632-199910150-00014","article-title":"Does spinal kyphotic deformity influence the biomechanical characteristics of the adjacent motion segments? An in vivo animal model","volume":"24","author":"Oda","year":"1999","journal-title":"Spine"},{"issue":"11","key":"10.1016\/j.spinee.2020.09.010_bib0033","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1007\/s00586-015-4188-3","article-title":"Symptomatic adjacent segment degeneration at the L3-4 level after fusion surgery at the L4-5 level: evaluation of the risk factors and 10-year incidence","volume":"24","author":"Heo","year":"2015","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2020.09.010_bib0034","series-title":"Joint structure and function: a comprehensive analysis","author":"Levangie","year":"2005"},{"issue":"8","key":"10.1016\/j.spinee.2020.09.010_bib0035","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/0021-9290(89)90077-8","article-title":"Experimental verification of facet load transmission by direct measurement of facet lamina contact pressure","volume":"22","author":"El-Bohy","year":"1989","journal-title":"J Biomech"},{"issue":"1","key":"10.1016\/j.spinee.2020.09.010_bib0036","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1186\/s12891-016-0980-4","article-title":"Biomechanical response of lumbar facet joints under follower preload: a finite element study","volume":"17","author":"Du","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"issue":"7","key":"10.1016\/j.spinee.2020.09.010_bib0037","doi-asserted-by":"crossref","DOI":"10.1115\/1.4004493","article-title":"Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions","volume":"133","author":"Jaumard","year":"2011","journal-title":"J Biomech Eng"},{"issue":"23","key":"10.1016\/j.spinee.2020.09.010_bib0038","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1097\/BRS.0b013e318158cb61","article-title":"Biologic response of the intervertebral disc to static and dynamic compression in vitro","volume":"32","author":"Wang","year":"2007","journal-title":"Spine"},{"issue":"6","key":"10.1016\/j.spinee.2020.09.010_bib0039","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1111\/j.1469-7580.2012.01521.x","article-title":"Diversity of intervertebral disc cells: phenotype and function","volume":"221","author":"Pattappa","year":"2012","journal-title":"J Anat"},{"issue":"4","key":"10.1016\/j.spinee.2020.09.010_bib0040","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1080\/10255842.2018.1448391","article-title":"Morphing the feature-based multi-blocks of normative\/healthy vertebral geometries to scoliosis vertebral geometries: development of personalized finite element models","volume":"21","author":"Hadagali","year":"2018","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"4","key":"10.1016\/j.spinee.2020.09.010_bib0041","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s005860000207","article-title":"Long-term follow-up of functional outcomes and radiographic changes at adjacent levels following lumbar spine fusion for degenerative disc disease","volume":"10","author":"Kumar","year":"2001","journal-title":"Eur Spine J"},{"issue":"7","key":"10.1016\/j.spinee.2020.09.010_bib0042","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.2106\/00004623-200407000-00020","article-title":"Adjacent segment degeneration in the lumbar spine","volume":"86","author":"Ghiselli","year":"2004","journal-title":"J Bone Joint Surg Am Vol"},{"issue":"17","key":"10.1016\/j.spinee.2020.09.010_bib0043","doi-asserted-by":"crossref","first-page":"1938","DOI":"10.1097\/01.brs.0000137069.88904.03","article-title":"Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature","volume":"29","author":"Park","year":"2004","journal-title":"Spine"},{"issue":"10","key":"10.1016\/j.spinee.2020.09.010_bib0044","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.spinee.2013.03.020","article-title":"Adjacent segment disease in the lumbar spine following different treatment interventions","volume":"13","author":"Radcliff","year":"2013","journal-title":"Spine J"},{"issue":"2","key":"10.1016\/j.spinee.2020.09.010_bib0045","doi-asserted-by":"crossref","first-page":"E55","DOI":"10.1097\/BRS.0000000000001148","article-title":"Biomechanics of a posterior lumbar motion stabilizing device: in vitro: comparison to intact and fused conditions","volume":"41","author":"Perez-Orribo","year":"2016","journal-title":"Spine"},{"issue":"8","key":"10.1016\/j.spinee.2020.09.010_bib0046","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1007\/s00586-017-5415-x","article-title":"Biomechanical investigation of lumbar hybrid stabilization in two-level posterior instrumentation","volume":"27","author":"Hegewald","year":"2018","journal-title":"Eur Spine J"}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943020311347?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943020311347?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T21:34:26Z","timestamp":1761514466000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943020311347"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["S1529943020311347"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2020.09.010","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Misaligned spinal rods can induce high internal forces consistent with those observed to cause screw pullout and disc degeneration","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2020.09.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}