{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T08:27:19Z","timestamp":1770539239609,"version":"3.49.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,1,5]],"date-time":"2023-01-05T00:00:00Z","timestamp":1672876800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","thespinejournalonline.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Spine Journal"],"published-print":{"date-parts":[[2023,5]]},"DOI":"10.1016\/j.spinee.2022.12.017","type":"journal-article","created":{"date-parts":[[2023,1,7]],"date-time":"2023-01-07T02:10:53Z","timestamp":1673057453000},"page":"766-779","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical evaluation of a novel tri-blade titanium implantable vertebral augmentation device"],"prefix":"10.1016","volume":"23","author":[{"given":"Chi-Tun","family":"Tang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tzu-Tsao","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huang-Chien","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5958-0949","authenticated-orcid":false,"given":"Chun-Li","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.spinee.2022.12.017_bib0001","doi-asserted-by":"crossref","first-page":"46","DOI":"10.7812\/TPP\/12-037","article-title":"Evaluation and management of vertebral compression fractures","volume":"16","author":"Alexandru","year":"2012","journal-title":"Perm J"},{"issue":"5","key":"10.1016\/j.spinee.2022.12.017_bib0002","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.spinee.2006.04.013","article-title":"Osteoporotic compression fractures of the spine; current options and considerations for treatment","volume":"6","author":"Kim","year":"2006","journal-title":"Spine J"},{"issue":"4","key":"10.1016\/j.spinee.2022.12.017_bib0003","article-title":"Re-expansion of osteoporotic compression fractures using bilateral SpineJack implants: early clinical experience and biomechanical considerations","volume":"11","author":"Jacobson","year":"2019","journal-title":"Cureus"},{"key":"10.1016\/j.spinee.2022.12.017_bib0004","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/173872","article-title":"Clinical performance and safety of 108 SpineJack implantations: 1-year results of a prospective multicentre single-arm registry study","volume":"2015","author":"Noriega","year":"2015","journal-title":"BioMed Res Int"},{"issue":"3","key":"10.1016\/j.spinee.2022.12.017_bib0005","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/BSD.0b013e318213c113","article-title":"Comparison of kyphoplasty and vertebroplasty for treatment of painful osteoporotic vertebral compression fractures: twelve-month follow-up in a prospective nonrandomized comparative study","volume":"25","author":"Li","year":"2012","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"10.1016\/j.spinee.2022.12.017_bib0006","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1056\/NEJMoa0900429","article-title":"A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures","volume":"361","author":"Buchbinder","year":"2009","journal-title":"N Engl J Med"},{"issue":"5","key":"10.1016\/j.spinee.2022.12.017_bib0007","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.spinee.2013.06.094","article-title":"Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: a cadaveric study","volume":"15","author":"Kr\u00fcger","year":"2015","journal-title":"Spine J"},{"issue":"16","key":"10.1016\/j.spinee.2022.12.017_bib0008","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1097\/01.brs.0000173895.19334.e2","article-title":"The reduction of endplate fractures during balloon vertebroplasty: a detailed radiological analysis of the treatment of burst fractures using pedicle screws, balloon vertebroplasty, and calcium phosphate cement","volume":"30","author":"Verlaan","year":"2005","journal-title":"Spine"},{"issue":"24","key":"10.1016\/j.spinee.2022.12.017_bib0009","doi-asserted-by":"crossref","first-page":"2806","DOI":"10.1097\/01.brs.0000190885.85675.a0","article-title":"Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures","volume":"30","author":"Voggenreiter","year":"2005","journal-title":"Spine"},{"issue":"7","key":"10.1016\/j.spinee.2022.12.017_bib0010","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.clinbiomech.2015.04.015","article-title":"Minimum cement volume required in vertebral body augmentation\u2014a biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture","volume":"30","author":"Rotter","year":"2015","journal-title":"Clin Biomech"},{"issue":"6","key":"10.1016\/j.spinee.2022.12.017_bib0011","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1007\/s00586-010-1341-x","article-title":"Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty","volume":"19","author":"Rotter","year":"2010","journal-title":"Eur Spine J"},{"issue":"7","key":"10.1016\/j.spinee.2022.12.017_bib0012","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.otsr.2015.08.009","article-title":"Treatment of vertebral compression fractures with the cranio-caudal expandable implant SpineJack\u00ae: technical note and outcomes in 77 consecutive patients","volume":"101","author":"Renaud","year":"2015","journal-title":"Orthop Traumatol-Sur"},{"issue":"1","key":"10.1016\/j.spinee.2022.12.017_bib0013","doi-asserted-by":"crossref","first-page":"13","DOI":"10.21037\/jss.2016.02.01","article-title":"Third-generation percutaneous vertebral augmentation systems","volume":"2","author":"Vanni","year":"2016","journal-title":"J Spine Surg"},{"issue":"11","key":"10.1016\/j.spinee.2022.12.017_bib0014","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.1016\/j.spinee.2019.07.009","article-title":"A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study)","volume":"19","author":"Noriega","year":"2019","journal-title":"Spine J"},{"issue":"3","key":"10.1016\/j.spinee.2022.12.017_bib0015","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1007\/s00198-018-4773-5","article-title":"Long-term safety and clinical performance of kyphoplasty and SpineJack\u00ae procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study","volume":"30","author":"Noriega","year":"2019","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.spinee.2022.12.017_bib0016","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.wneu.2017.05.142","article-title":"Requirements for a stable long-term result in surgical reduction of vertebral fragility fractures","volume":"105","author":"Crespo-Sanju\u00e1n","year":"2017","journal-title":"World Neurosurg"},{"issue":"6","key":"10.1016\/j.spinee.2022.12.017_bib0017","doi-asserted-by":"crossref","DOI":"10.1063\/2.1106401","article-title":"A non-linear finite element model of human L4-L5 lumbar spinal segment with three dimensional solid element ligaments","volume":"1","author":"Xiao","year":"2011","journal-title":"Theor Appl Mechanics Lett"},{"issue":"6","key":"10.1016\/j.spinee.2022.12.017_bib0018","first-page":"789","article-title":"A method to develop an in vitro osteoporosis model of porcine vertebrae: histological and biomechanical study","volume":"14","author":"Lee","year":"2011","journal-title":"J Neurosurg"},{"issue":"16","key":"10.1016\/j.spinee.2022.12.017_bib0019","doi-asserted-by":"crossref","first-page":"3126","DOI":"10.1016\/j.jbiomech.2010.08.002","article-title":"Mechanisms of initial endplate failure in the human vertebral body","volume":"43","author":"Fields","year":"2010","journal-title":"J Biomech"},{"key":"10.1016\/j.spinee.2022.12.017_bib0020","first-page":"1415","article-title":"Clinical results for the use of a new extensible cranio-caudal implant for the treatment of vertebral compression fractures results of a prospective, multicentre study after 1 year of follow-up","volume":"21","author":"Noriega","year":"2012","journal-title":"Eur Spine J"},{"issue":"9","key":"10.1016\/j.spinee.2022.12.017_bib0021","first-page":"e17795","article-title":"Expandable intravertebral implants: a narrative review on the concept, biomechanics, and outcomes in traumatology","volume":"13","author":"Moura","year":"2021","journal-title":"Cureus"},{"issue":"3","key":"10.1016\/j.spinee.2022.12.017_bib0022","doi-asserted-by":"crossref","first-page":"379","DOI":"10.21037\/jss.2017.08.06","article-title":"Corpectomy and expandable cage replacement versus third generation percutaneous augmentation system in case of vertebra plana: rationale and recommendations","volume":"3","author":"Vanni","year":"2017","journal-title":"J Spine Surg"},{"issue":"2","key":"10.1016\/j.spinee.2022.12.017_bib0023","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.clinbiomech.2007.09.011","article-title":"Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month","volume":"23","author":"Antonius","year":"2008","journal-title":"Clin Biomech"},{"issue":"11","key":"10.1016\/j.spinee.2022.12.017_bib0024","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1097\/BRS.0b013e3181722d52","article-title":"Loads on a telemeterized vertebral body replacement measured in two patients","volume":"33","author":"Antonius","year":"2008","journal-title":"Spine"},{"issue":"1","key":"10.1016\/j.spinee.2022.12.017_bib0025","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","article-title":"Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures","volume":"85","author":"Yeom","year":"2003","journal-title":"J Bone Joint Surg Br"},{"issue":"16","key":"10.1016\/j.spinee.2022.12.017_bib0026","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1097\/01.brs.0000173895.19334.e2","article-title":"The reduction of endplate fractures during balloon vertebroplasty: a detailed radiological analysis of the treatment of burst fractures using pedicle screws, balloon vertebroplasty, and calcium phosphate cement","volume":"30","author":"Verlaan","year":"2005","journal-title":"Spine"},{"issue":"3","key":"10.1016\/j.spinee.2022.12.017_bib0027","first-page":"236","article-title":"Osteoporotic spinal deformity: a biomechanical rationale for the clinical consequences and treatment of vertebral body compression fractures","volume":"17","author":"Yuan","year":"2004","journal-title":"Clin Spine Surg"},{"issue":"10","key":"10.1016\/j.spinee.2022.12.017_bib0028","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1007\/s00270-018-1987-z","article-title":"New implant-based technologies in the spine","volume":"41","author":"Filippiadis","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"7","key":"10.1016\/j.spinee.2022.12.017_bib0029","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1007\/s00586-010-1326-9","article-title":"Comparative anatomical dimensions of the complete human and porcine spine","volume":"19","author":"Busscher","year":"2010","journal-title":"Eur Spine J"},{"key":"10.1016\/j.spinee.2022.12.017_bib0030","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jocn.2021.04.031","article-title":"Clinical outcomes and safety of the SpineJack vertebral augmentation system for the treatment of vertebral compression fractures in a United States patient population","volume":"89","author":"England","year":"2021","journal-title":"J Clin Neurosci"},{"issue":"6","key":"10.1016\/j.spinee.2022.12.017_bib0031","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.1007\/s00198-016-3494-x","article-title":"Safety and clinical performance of kyphoplasty and SpineJack(\u00ae) procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study","volume":"27","author":"Noriega","year":"2016","journal-title":"Osteoporos Int"},{"issue":"1","key":"10.1016\/j.spinee.2022.12.017_bib0032","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/s12893-020-00733-8","article-title":"Cement leakage following percutaneous kyphoplasty in a patient after a posterior lumbar fusion: a case report","volume":"20","author":"Li","year":"2020","journal-title":"BMC Surg"},{"issue":"7","key":"10.1016\/j.spinee.2022.12.017_bib0033","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.clinbiomech.2015.04.015","article-title":"Minimum cement volume required in vertebral body augmentation\u2013a biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture","volume":"30","author":"Rotter","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)."}],"container-title":["The Spine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943023000037?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1529943023000037?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T21:38:20Z","timestamp":1761514700000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1529943023000037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5]]}},"alternative-id":["S1529943023000037"],"URL":"https:\/\/doi.org\/10.1016\/j.spinee.2022.12.017","relation":{},"ISSN":["1529-9430"],"issn-type":[{"value":"1529-9430","type":"print"}],"subject":[],"published":{"date-parts":[[2023,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical evaluation of a novel tri-blade titanium implantable vertebral augmentation device","name":"articletitle","label":"Article Title"},{"value":"The Spine Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.spinee.2022.12.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}