{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T14:22:31Z","timestamp":1792678951504,"version":"4.5.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2014,2,1]],"date-time":"2014-02-01T00:00:00Z","timestamp":1391212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Surgery"],"published-print":{"date-parts":[[2014,2]]},"DOI":"10.1016\/j.surg.2013.08.015","type":"journal-article","created":{"date-parts":[[2013,9,29]],"date-time":"2013-09-29T12:46:57Z","timestamp":1380458817000},"page":"329-339","source":"Crossref","is-referenced-by-count":104,"title":["Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: A porcine model"],"prefix":"10.1016","volume":"155","author":[{"given":"Che-Wei","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianlorenzo","family":"Dionigi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoli","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hoon Yub","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pi-Jung","family":"Hsiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo-Bow","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui-Chun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiu-Ya","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pi-Ying","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I-Cheng","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feng-Yu","family":"Chiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.surg.2013.08.015_bib1","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.surg.2004.09.008","article-title":"Recurrent laryngeal nerve palsy after thyroidectomy with routine identification of the recurrent laryngeal nerve","volume":"137","author":"Chiang","year":"2005","journal-title":"Surgery"},{"key":"10.1016\/j.surg.2013.08.015_bib2","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.surg.2004.07.018","article-title":"Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery","volume":"136","author":"Dralle","year":"2004","journal-title":"Surgery"},{"key":"10.1016\/j.surg.2013.08.015_bib3","series-title":"Surgery of the thyroid and parathyroid glands","first-page":"300","article-title":"Surgical anatomy of the recurrent laryngeal nerve","author":"Randolph","year":"2003"},{"key":"10.1016\/j.surg.2013.08.015_bib4","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1001\/archsurg.135.2.204","article-title":"A\u00a0prospective evaluation of recurrent laryngeal nerve paralysis during thyroidectomy","volume":"135","author":"Lo","year":"2000","journal-title":"Arch Surg"},{"issue":"Suppl 1","key":"10.1016\/j.surg.2013.08.015_bib5","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1002\/lary.21119","article-title":"Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement","volume":"121","author":"Randolph","year":"2011","journal-title":"Laryngoscope"},{"key":"10.1016\/j.surg.2013.08.015_bib6","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1007\/s00268-008-9483-2","article-title":"Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery","volume":"32","author":"Dralle","year":"2008","journal-title":"World J Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib7","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.surg.2008.02.006","article-title":"The mechanism of recurrent laryngeal nerve injury during thyroid surgery\u2013the application of intraoperative neuromonitoring","volume":"143","author":"Chiang","year":"2008","journal-title":"Surgery"},{"key":"10.1016\/j.surg.2013.08.015_bib8","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.jamcollsurg.2007.07.017","article-title":"Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy","volume":"206","author":"Snyder","year":"2008","journal-title":"J\u00a0Am Coll Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib9","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00268-009-0316-8","article-title":"Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation","volume":"34","author":"Chiang","year":"2010","journal-title":"World J Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib10","doi-asserted-by":"crossref","first-page":"2601","DOI":"10.1007\/s00464-012-2239-y","article-title":"Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring","volume":"26","author":"Dionigi","year":"2012","journal-title":"Surg Endosc"},{"key":"10.1016\/j.surg.2013.08.015_bib11","article-title":"Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury","author":"Schneider","year":"2012","journal-title":"Head Neck"},{"key":"10.1016\/j.surg.2013.08.015_bib12","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1080\/13645700701383241","article-title":"A\u00a0new system for continuous recurrent laryngeal nerve monitoring","volume":"16","author":"Lamade","year":"2007","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"10.1016\/j.surg.2013.08.015_bib13","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.surg.2007.10.007","article-title":"Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial","volume":"143","author":"Ulmer","year":"2008","journal-title":"Surgery"},{"key":"10.1016\/j.surg.2013.08.015_bib14","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s00423-009-0503-y","article-title":"A\u00a0new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations","volume":"394","author":"Schneider","year":"2009","journal-title":"Langenbecks Arch Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib15","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1007\/s00268-012-1853-0","article-title":"Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring","volume":"37","author":"Schneider","year":"2013","journal-title":"World J Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib16","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1002\/hed.21324","article-title":"Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model","volume":"32","author":"Wu","year":"2010","journal-title":"Head Neck"},{"key":"10.1016\/j.surg.2013.08.015_bib17","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.amjsurg.2009.04.036","article-title":"A\u00a0new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve","volume":"199","author":"Schneider","year":"2010","journal-title":"Am J Surg"},{"key":"10.1016\/j.surg.2013.08.015_bib18","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/S1607-551X(10)70097-8","article-title":"Intraoperative neuromonitoring for early localization and identification of the recurrent laryngeal nerve during thyroid surgery","volume":"26","author":"Chiang","year":"2010","journal-title":"Kaohsiung J Med Sci"},{"key":"10.1016\/j.surg.2013.08.015_bib19","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/S1607-551X(10)70098-X","article-title":"Electromyographic study of differential sensitivity to succinylcholine of the diaphragm, laryngeal and somatic muscles: a swine model","volume":"26","author":"Lu","year":"2010","journal-title":"Kaohsiung J Med Sci"}],"container-title":["Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S003960601300473X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S003960601300473X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,12]],"date-time":"2018-10-12T10:24:28Z","timestamp":1539339868000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S003960601300473X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,2]]}},"alternative-id":["S003960601300473X"],"URL":"https:\/\/doi.org\/10.1016\/j.surg.2013.08.015","relation":{},"ISSN":["0039-6060"],"issn-type":[{"value":"0039-6060","type":"print"}],"subject":[],"published":{"date-parts":[[2014,2]]}}}