{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T14:30:52Z","timestamp":1744209052005,"version":"3.37.3"},"reference-count":29,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["surgjournal.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Surgery"],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.1016\/j.surg.2016.07.036","type":"journal-article","created":{"date-parts":[[2016,9,9]],"date-time":"2016-09-09T15:40:55Z","timestamp":1473435655000},"page":"477-484","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparative analysis between a bipolar vessel sealing and cutting device and the tie and suture technique in thyroidectomy: A\u00a0randomized clinical trial"],"prefix":"10.1016","volume":"161","author":[{"given":"K. Ver\u00f3nica","family":"Chavez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. Manuel","family":"Barajas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaqueline","family":"Ram\u00edrez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan Pablo","family":"Pantoja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauricio","family":"Sierra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Vel\u00e1zquez-Fernandez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel F.","family":"Herrera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.surg.2016.07.036_bib1","doi-asserted-by":"crossref","first-page":"3056","DOI":"10.1007\/s00464-013-2823-9","article-title":"Common uses and cited complications of energy in surgery","volume":"27","author":"Sankaranarayanan","year":"2013","journal-title":"Surg Endosc"},{"key":"10.1016\/j.surg.2016.07.036_bib2","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1177\/1553350608324933","article-title":"Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis","volume":"15","author":"Macario","year":"2008","journal-title":"Surg Innov"},{"key":"10.1016\/j.surg.2016.07.036_bib3","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/00004311-200010000-00009","article-title":"Operating room utilization: the need for data","volume":"38","author":"Viapiano","year":"2000","journal-title":"Int Anesthesiol Clin"},{"key":"10.1016\/j.surg.2016.07.036_bib4","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.jamcollsurg.2014.12.040","article-title":"How slow is too slow? Correlation of operative time to complications: an analysis from the Tennessee Surgical Quality Collaborative","volume":"220","author":"Daley","year":"2015","journal-title":"J\u00a0Am Coll Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib5","first-page":"249","article-title":"Complications after total thyroidectomy","volume":"150","author":"Christou","year":"2013","journal-title":"J\u00a0Visc Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib6","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s00268-003-6903-1","article-title":"Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years","volume":"28","author":"Rosato","year":"2004","journal-title":"World J Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib7","first-page":"1837","article-title":"Risk factors target in patients with post-thyroidectomy bleeding","volume":"7","author":"Chen","year":"2014","journal-title":"Int J Clin Exp Med"},{"key":"10.1016\/j.surg.2016.07.036_bib8","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.1245\/s10434-012-2849-6","article-title":"A\u00a0systematic review and meta-analysis comparing the efficacy and surgical outcomes of total thyroidectomy between harmonic scalpel versus ligasure","volume":"20","author":"Lang","year":"2013","journal-title":"Ann Surg Oncol"},{"key":"10.1016\/j.surg.2016.07.036_bib9","doi-asserted-by":"crossref","first-page":"355","DOI":"10.2478\/v10035-011-0056-y","article-title":"Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStaplerTM during thyroidectomy","volume":"83","author":"Brzezi\u0144ski","year":"2011","journal-title":"Pol Przegl Chir"},{"key":"10.1016\/j.surg.2016.07.036_bib10","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1001\/archsurg.137.2.137","article-title":"The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery","volume":"2","author":"Siperstein","year":"2002","journal-title":"Arch Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib11","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1007\/s00423-013-1137-7","article-title":"ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery\u2014the ENERCON systematic review and network meta-analysis","volume":"398","author":"Contin","year":"2013","journal-title":"Langenbecks Arch Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib12","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1186\/1477-7819-8-112","article-title":"Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie","volume":"8","author":"Cirocchi","year":"2010","journal-title":"World J Surg Oncol"},{"key":"10.1016\/j.surg.2016.07.036_bib13","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1245\/s10434-010-1334-3","article-title":"A\u00a0comparison of the LigaSure and harmonic scalpel in thyroid surgery: a single institution review","volume":"18","author":"Zarebczan","year":"2011","journal-title":"Ann Surg Oncol"},{"key":"10.1016\/j.surg.2016.07.036_bib14","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.surg.2004.09.011","article-title":"A\u00a0randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy","volume":"137","author":"Cord\u00f3n","year":"2005","journal-title":"Surgery"},{"key":"10.1016\/j.surg.2016.07.036_bib15","first-page":"206","article-title":"Product: EnSealTM. Reviews in obstetrics and gynecology","author":"Greenberg","year":"2009","journal-title":"MedReviews, LLC"},{"key":"10.1016\/j.surg.2016.07.036_bib16","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1002\/hed.22932","article-title":"Initial experience using a bipolar radiofrequency ablation device for hemostasis during thyroidectomy","volume":"35","author":"Baldwin","year":"2013","journal-title":"Head Neck"},{"key":"10.1016\/j.surg.2016.07.036_bib17","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1245\/s10434-014-3785-4","article-title":"Assessing safety and outcomes in outpatient versus inpatient thyroidectomy using the NSQIP: a propensity score matched analysis of 16,370 patients","volume":"22","author":"Khavanin","year":"2015","journal-title":"Ann Surg Oncol"},{"key":"10.1016\/j.surg.2016.07.036_bib18","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1177\/0194599812454401","article-title":"Thyroidectomy outcomes: a national perspective","volume":"147","author":"Vashishta","year":"2012","journal-title":"Otolaryngol Head Neck Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib19","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1007\/s00423-008-0366-7","article-title":"Complications to thyroid surgery: results as reported in a database from a multicenter audit comprising 3,660 patients","volume":"393","author":"Bergenfelz","year":"2008","journal-title":"Langenbecks Arch Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib20","first-page":"48","article-title":"Suture-less thyroidectomy using harmonic scalpel versus conventional thyroidectomy: a randomized controlled trial","volume":"6","author":"Aziz","year":"2016","journal-title":"J\u00a0Pakistan Med Students"},{"key":"10.1016\/j.surg.2016.07.036_bib21","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1001\/archsurg.2009.201","article-title":"Prospective clinical trials of thyroidectomy with LigaSure vs conventional vessel ligation: a systematic review and meta-analysis","volume":"144","author":"Yao","year":"2009","journal-title":"Arch Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib22","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s13044-015-0027-1","article-title":"A\u00a0systematic review and meta-analysis of Harmonic Focus in thyroidectomy compared to conventional techniques","volume":"8","author":"Cheng","year":"2015","journal-title":"Thyroid Res"},{"key":"10.1016\/j.surg.2016.07.036_bib23","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00464-008-9932-x","article-title":"Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices","volume":"23","author":"Newcomb","year":"2009","journal-title":"Surg Endosc Other Interv Tech"},{"issue":"3","key":"10.1016\/j.surg.2016.07.036_bib24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4293\/JSLS.2014.00182","article-title":"Sealing of vessels larger than 7 millimeters using Enseal in porcine aorta","volume":"18","author":"Bibi","year":"2014","journal-title":"JSLS"},{"key":"10.1016\/j.surg.2016.07.036_bib25","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/s00276-008-0405-7","article-title":"Clinically relevant variations of the superior thyroid artery: an anatomic guide for surgical neck dissection","volume":"31","author":"Ozgur","year":"2009","journal-title":"Surg Radiol Anat"},{"key":"10.1016\/j.surg.2016.07.036_bib26","doi-asserted-by":"crossref","first-page":"3334","DOI":"10.1007\/s00464-012-2337-x","article-title":"Efficacy and safety of the novel electrosurgical vessel sealing and cutting instrument BiCision\u00ae","volume":"26","author":"Rothmund","year":"2012","journal-title":"Surg Endosc"},{"key":"10.1016\/j.surg.2016.07.036_bib27","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1007\/s00268-005-0355-8","article-title":"Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy","volume":"30","author":"Chan","year":"2006","journal-title":"World J Surg"},{"key":"10.1016\/j.surg.2016.07.036_bib28","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1007\/s001040051099","volume":"71","author":"Friedrich","year":"2000","journal-title":"Chirurg"},{"key":"10.1016\/j.surg.2016.07.036_bib29","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1159\/000099599","article-title":"Histopathological effects of bipolar vessel sealing devices on liver parenchyma and comparison with suture method: an experimental study","volume":"39","author":"Sahin","year":"2007","journal-title":"Eur Surg Res"}],"container-title":["Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039606016304135?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039606016304135?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,4,5]],"date-time":"2021-04-05T22:53:06Z","timestamp":1617663186000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0039606016304135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["S0039606016304135"],"URL":"https:\/\/doi.org\/10.1016\/j.surg.2016.07.036","relation":{},"ISSN":["0039-6060"],"issn-type":[{"type":"print","value":"0039-6060"}],"subject":[],"published":{"date-parts":[[2017,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative analysis between a bipolar vessel sealing and cutting device and the tie and suture technique in thyroidectomy: A\u00a0randomized clinical trial","name":"articletitle","label":"Article Title"},{"value":"Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.surg.2016.07.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}