{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T10:27:01Z","timestamp":1794479221528,"version":"4.9.1"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:00:00Z","timestamp":1777507200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","surgjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Surgery"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.surg.2026.110297","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T21:22:37Z","timestamp":1777929757000},"page":"110297","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Donor liver weight in normothermic machine perfusion: Does size really matter?"],"prefix":"10.1016","volume":"196","author":[{"given":"Braxton","family":"Goodnight","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Kalbfell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neeta","family":"Vachharajani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangyu","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Lindemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ola","family":"Ahmed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Alomar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franklin","family":"Olumba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.B. Majella","family":"Doyle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William C.","family":"Chapman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adeel S.","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-3750-6933","authenticated-orcid":false,"given":"Brendan P.","family":"Lovasik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.surg.2026.110297_bib1","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1111\/ajt.13708","article-title":"Liver transplantation after ex vivo normothermic machine preservation: a phase 1 (First-in-Man) clinical trial","volume":"16","author":"Ravikumar","year":"2016","journal-title":"Am J Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib2","doi-asserted-by":"crossref","first-page":"3718","DOI":"10.3390\/jcm12113718","article-title":"Normothermic ex vivo machine perfusion for liver transplantation: a systematic review of progress in humans","volume":"12","author":"Risbey","year":"2023","journal-title":"J Clin Med"},{"key":"10.1016\/j.surg.2026.110297_bib3","doi-asserted-by":"crossref","first-page":"4648","DOI":"10.3390\/ijms25094648","article-title":"Steatotic donor transplant livers: preservation strategies to mitigate against ischaemia-reperfusion injury","volume":"25","author":"Abbas","year":"2024","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.surg.2026.110297_bib4","doi-asserted-by":"crossref","first-page":"e912","DOI":"10.1097\/SLA.0000000000005934","article-title":"Normothermic machine perfusion of donor livers for transplantation in the United States: a randomized controlled trial","volume":"278","author":"Chapman","year":"2023","journal-title":"Ann Surg"},{"key":"10.1016\/j.surg.2026.110297_bib5","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/MOT.0000000000001141","article-title":"Normothermic machine perfusion for liver transplantation: current state and future directions","volume":"29","author":"Lindemann","year":"2024","journal-title":"Curr Opin Organ Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib6","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1001\/jamasurg.2021.6781","article-title":"Impact of portable normothermic blood-based machine perfusion on outcomes of liver transplant: the OCS liver PROTECT randomized clinical trial","volume":"157","author":"Markmann","year":"2022","journal-title":"JAMA Surg"},{"key":"10.1016\/j.surg.2026.110297_bib7","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1038\/s41586-018-0047-9","article-title":"A randomized trial of normothermic preservation in liver transplantation","volume":"557","author":"Nasralla","year":"2018","journal-title":"Nature"},{"key":"10.1016\/j.surg.2026.110297_bib8","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1001\/jamasurg.2024.6520","article-title":"Improved outcomes and resource use with normothermic machine perfusion in liver transplantation","volume":"160","author":"Nguyen","year":"2025","journal-title":"JAMA Surg"},{"key":"10.1016\/j.surg.2026.110297_bib9","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1097\/XCS.0000000000000555","article-title":"Normothermic machine perfusion for declined livers: a strategy to rescue marginal livers for transplantation","volume":"236","author":"Olumba","year":"2023","journal-title":"J Am Coll Surg"},{"key":"10.1016\/j.surg.2026.110297_bib10","doi-asserted-by":"crossref","DOI":"10.1097\/TXD.0000000000001679","article-title":"Normothermic machine perfusion is associated with improvement in mortality and graft failure in donation after cardiac death liver transplant recipients in the United States","volume":"10","author":"Okumura","year":"2024","journal-title":"Transpl Direct"},{"key":"10.1016\/j.surg.2026.110297_bib11","doi-asserted-by":"crossref","first-page":"2939","DOI":"10.1038\/s41467-020-16251-3","article-title":"Transplantation of discarded livers following viability testing with normothermic machine perfusion","volume":"11","author":"Mergental","year":"2020","journal-title":"Nat Commun"},{"key":"10.1016\/j.surg.2026.110297_bib12","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/XCS.0000000000000425","article-title":"Outcomes of liver transplantation using machine perfusion in donation after cardiac death vs brain death in the US","volume":"236","author":"Okumura","year":"2023","journal-title":"J Am Coll Surg"},{"key":"10.1016\/j.surg.2026.110297_bib13","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1002\/lt.24806","article-title":"Liver graft preservation using perfluorocarbon improves the outcomes of simulated donation after cardiac death liver transplantation in rats","volume":"23","author":"Okumura","year":"2017","journal-title":"Liver Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib14","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1111\/ajt.12187","article-title":"Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers","volume":"13","author":"op den Dries","year":"2013","journal-title":"Am J Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib15","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1097\/TP.0000000000004970","article-title":"Localized liver injury during normothermic ex situ liver perfusion has no impact on short-term liver transplant outcomes","volume":"108","author":"Martin","year":"2024","journal-title":"Transplantation"},{"key":"10.1016\/j.surg.2026.110297_bib16","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1177\/039139889301601010","article-title":"Extracorporeal liver perfusion: applications of an improved model for experimental studies of the liver","volume":"16","author":"Neuhaus","year":"1993","journal-title":"Int J Artif Organs"},{"key":"10.1016\/j.surg.2026.110297_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajt.2024.12.227","article-title":"Cradle compression during normothermic machine perfusion in liver transplantation: incidence and impact on postoperative outcomes","volume":"25","author":"Imai","year":"2025","journal-title":"Am J Transplant"},{"key":"10.1016\/j.surg.2026.110297_bib18","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1016\/j.ajt.2024.12.048","article-title":"Factors associated with liver cradle compression effect following normothermic machine perfusion","volume":"25","author":"Subramanian","year":"2025","journal-title":"Am J Transplant"},{"key":"10.1016\/j.surg.2026.110297_bib19","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1097\/TP.0000000000004263","article-title":"Predicting early allograft function after normothermic machine perfusion","volume":"106","author":"Watson","year":"2022","journal-title":"Transplantation"},{"key":"10.1016\/j.surg.2026.110297_bib20","doi-asserted-by":"crossref","DOI":"10.1097\/TXD.0000000000001243","article-title":"Dual lactate clearance in the viability assessment of livers donated after circulatory death with ex situ normothermic machine perfusion","volume":"7","author":"Xu","year":"2021","journal-title":"Transpl Direct"},{"key":"10.1016\/j.surg.2026.110297_bib21","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1002\/lt.25291","article-title":"Development of clinical criteria for functional assessment to predict primary nonfunction of high-risk livers using normothermic machine perfusion","volume":"24","author":"Mergental","year":"2018","journal-title":"Liver Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib22","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1002\/lt.22091","article-title":"Validation of a current definition of early allograft dysfunction in liver transplant recipients and analysis of risk factors","volume":"16","author":"Olthoff","year":"2010","journal-title":"Liver Transpl"},{"issue":"4 Suppl 3","key":"10.1016\/j.surg.2026.110297_bib23","first-page":"54","article-title":"Postreperfusion syndrome: cardiovascular collapse following hepatic reperfusion during liver transplantation","volume":"19","author":"Aggarwal","year":"1987","journal-title":"Transpl Proc"},{"key":"10.1016\/j.surg.2026.110297_bib24","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1002\/lt.21381","article-title":"The impact of postreperfusion syndrome on short-term patient and liver allograft outcome in patients undergoing orthotopic liver transplantation","volume":"14","author":"Hilmi","year":"2008","journal-title":"Liver Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib25","doi-asserted-by":"crossref","first-page":"e28","DOI":"10.1097\/TP.0000000000003462","article-title":"Machine perfusion-leaving its mark on liver transplantation","volume":"105","author":"Richards","year":"2021","journal-title":"Transplantation"},{"key":"10.1016\/j.surg.2026.110297_bib26","doi-asserted-by":"crossref","first-page":"2005","DOI":"10.1111\/ajt.14687","article-title":"Observations on the ex situ perfusion of livers for transplantation","volume":"18","author":"Watson","year":"2018","journal-title":"Am J Transpl"},{"key":"10.1016\/j.surg.2026.110297_bib27","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1097\/TP.0000000000003857","article-title":"Perfusate enzymes and platelets indicate early allograft dysfunction after transplantation of normothermically preserved livers","volume":"106","author":"Weissenbacher","year":"2022","journal-title":"Transplantation"}],"container-title":["Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039606026002229?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039606026002229?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T09:33:54Z","timestamp":1794476034000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0039606026002229"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":27,"alternative-id":["S0039606026002229"],"URL":"https:\/\/doi.org\/10.1016\/j.surg.2026.110297","relation":{},"ISSN":["0039-6060"],"issn-type":[{"value":"0039-6060","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Donor liver weight in normothermic machine perfusion: Does size really matter?","name":"articletitle","label":"Article Title"},{"value":"Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.surg.2026.110297","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"110297"}}