{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T21:24:26Z","timestamp":1792272266189,"version":"4.4.0"},"reference-count":43,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T00:00:00Z","timestamp":1767744000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005969","name":"Universit\u00e0 di Bologna","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005969","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Talanta"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.talanta.2025.129346","type":"journal-article","created":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T15:06:40Z","timestamp":1767539200000},"page":"129346","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Analytical quality by design in the development of a paper-based microfluidic device for iron (II) determination as an impurity in iron (III) pharmaceuticals"],"prefix":"10.1016","volume":"301","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-2145-4785","authenticated-orcid":false,"given":"Muhammad","family":"Waqar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8706-3925","authenticated-orcid":false,"given":"Benedetta","family":"Pasquini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6000-5079","authenticated-orcid":false,"given":"Serena","family":"Orlandini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucrezia","family":"Floris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Furlanetto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0622-2248","authenticated-orcid":false,"given":"Roberto","family":"Gotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.talanta.2025.129346_bib1","doi-asserted-by":"crossref","first-page":"7091","DOI":"10.1021\/ac901071p","article-title":"Understanding wax printing: a simple micropatterning process for paper-based microfluidics","volume":"81","author":"Carrilho","year":"2009","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib2","doi-asserted-by":"crossref","first-page":"11835","DOI":"10.1021\/acs.chemrev.0c01335","article-title":"Microfluidic paper-based analytical devices: from design to applications","volume":"121","author":"Noviana","year":"2021","journal-title":"Chem. Rev."},{"key":"10.1016\/j.talanta.2025.129346_bib3","article-title":"Eco-sustainable point-of-care devices: progress in paper and fabric based electrochemical and colorimetric biosensors","volume":"285","author":"Lingadharini","year":"2024","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2025.129346_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2021.122733","article-title":"Sensory materials for microfluidic paper based analytical devices \u2013 a review","volume":"235","author":"Selvakumar","year":"2021","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2025.129346_bib5","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1039\/D2SD00017B","article-title":"Paper-based sensors for diagnostics, human activity monitoring, food safety and environmental detection","volume":"1","author":"Yao","year":"2022","journal-title":"Sens. Diagn"},{"key":"10.1016\/j.talanta.2025.129346_bib6","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1002\/elps.200800563","article-title":"Rapid prototyping of paper\u2010based microfluidics with wax for low\u2010cost, portable bioassay","volume":"30","author":"Lu","year":"2009","journal-title":"Electrophoresis"},{"key":"10.1016\/j.talanta.2025.129346_bib7","doi-asserted-by":"crossref","first-page":"2777","DOI":"10.1039\/D3AY02258G","article-title":"Paper-based sensors: affordable, versatile, and emerging analyte detection platforms","volume":"16","author":"Malik","year":"2024","journal-title":"Anal. Methods"},{"key":"10.1016\/j.talanta.2025.129346_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2023.125019","article-title":"Development of a biodegradable microfluidic paper-based device for blood-plasma separation integrated with non-enzymatic electrochemical detection of ascorbic acid","volume":"266","author":"Gautam","year":"2024","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2025.129346_bib9","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1007\/s42114-025-01333-x","article-title":"Advances in paper-based analytical devices relying on optical detection","volume":"8","author":"Wang","year":"2025","journal-title":"Adv. Compos. Hybrid Mater."},{"key":"10.1016\/j.talanta.2025.129346_bib10","article-title":"Sustainable and scalable detection: paper-based analytical devices and miniaturized detection systems for modern diagnostics","volume":"201","author":"Isa","year":"2025","journal-title":"Microchem. J."},{"key":"10.1016\/j.talanta.2025.129346_bib11","doi-asserted-by":"crossref","first-page":"2888","DOI":"10.1039\/C5RA23470K","article-title":"A simple method for fabrication of microfluidic paper-based analytical devices and on-device fluid control with a portable corona generator","volume":"6","author":"Jiang","year":"2016","journal-title":"RSC Adv."},{"key":"10.1016\/j.talanta.2025.129346_bib12","article-title":"Electrochemical paper-based microfluidics: harnessing capillary flow for advanced diagnostics","volume":"20","author":"Bezinge","year":"2024","journal-title":"Small"},{"key":"10.1016\/j.talanta.2025.129346_bib13","doi-asserted-by":"crossref","first-page":"10126","DOI":"10.1021\/acs.analchem.5c00128","article-title":"Paper as a sustainable material for smart electrochemical (bio)sensors with unprecedented features: a perspective","volume":"97","author":"Arduini","year":"2025","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib14","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.talanta.2019.05.081","article-title":"Electrochemical paper-based microfluidic device for high throughput multiplexed analysis","volume":"203","author":"Fava","year":"2019","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2025.129346_bib15","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1021\/acs.analchem.6b04581","article-title":"Paper-Based microfluidic devices: emerging themes and applications","volume":"89","author":"Yang","year":"2017","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib16","doi-asserted-by":"crossref","first-page":"6379","DOI":"10.1021\/acsbiomaterials.3c00736","article-title":"Controlling fluorescent readout in paper-based analytical devices","volume":"9","author":"Luongo","year":"2023","journal-title":"ACS Biomater. Sci. Eng."},{"key":"10.1016\/j.talanta.2025.129346_bib17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2017.03.037","article-title":"Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (\u03bcPADs) \u2013 a review","volume":"970","author":"Morbioli","year":"2017","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.talanta.2025.129346_bib18","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.bios.2017.11.021","article-title":"Smartphone based bioanalytical and diagnosis applications: a review","volume":"102","author":"Kanchi","year":"2018","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.talanta.2025.129346_bib19","doi-asserted-by":"crossref","DOI":"10.1016\/j.microc.2023.108879","article-title":"Use of scanners for colorimetric analysis of microfluidic paper-based analytical devices (\u03bcPADs): a practical guide","volume":"191","author":"Uhlikova","year":"2023","journal-title":"Microchem. J."},{"key":"10.1016\/j.talanta.2025.129346_bib20","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3390\/s21010101","article-title":"Predicting dimensions in microfluidic paper-based analytical devices","volume":"21","author":"Catalan-Carrio","year":"2020","journal-title":"Sensors"},{"key":"10.1016\/j.talanta.2025.129346_bib21","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1007\/s10404-023-02679-8","article-title":"Maximizing flow rate in single paper layer, rapid flow microfluidic paper-based analytical devices","volume":"27","author":"Macleod Briongos","year":"2023","journal-title":"Microfluid. Nanofluidics"},{"key":"10.1016\/j.talanta.2025.129346_bib22","doi-asserted-by":"crossref","DOI":"10.1051\/matecconf\/202338101009","article-title":"Flow control in paper-based microfluidic channel by using hydrophobic tape barrier on the paper surface","volume":"381","author":"Ali","year":"2023","journal-title":"MATEC Web Conf."},{"key":"10.1016\/j.talanta.2025.129346_bib23","doi-asserted-by":"crossref","DOI":"10.1021\/acssensors.5c02031","article-title":"A machine learning-driven cyclic optimizing strategy for the construction of paper-based microfluidic devices in the early diagnosis of periodontitis","author":"Lv","year":"2025","journal-title":"ACS Sens."},{"key":"10.1016\/j.talanta.2025.129346_bib24","series-title":"Pharmaceutical Experimental Design","author":"Lewis","year":"2019"},{"key":"10.1016\/j.talanta.2025.129346_bib26","doi-asserted-by":"crossref","first-page":"2087","DOI":"10.1517\/14656566.2014.953928","article-title":"Iron sucrose \u2013 characteristics, efficacy and regulatory aspects of an established treatment of iron deficiency and iron-deficiency anemia in a broad range of therapeutic areas","volume":"15","author":"Beguin","year":"2014","journal-title":"Expet Opin. Pharmacother."},{"key":"10.1016\/j.talanta.2025.129346_bib27","series-title":"Rockville: the United States Pharmacopeial Convention","article-title":"National formulary USP 38\u2014NF 33","author":"Pharmacopeia","year":"2015"},{"key":"10.1016\/j.talanta.2025.129346_bib28","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3390\/chemosensors11020101","article-title":"Iron determination in natural waters using a synthesised 3-hydroxy-4-pyridione ligand in a newly developed microfluidic paper-based device","volume":"11","author":"Aguiar","year":"2023","journal-title":"Chemosensors"},{"key":"10.1016\/j.talanta.2025.129346_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2022.123914","article-title":"Integrated calibration and serum iron in situ analysis into an array microfluidic paper-based analytical device with smartphone readout","volume":"253","author":"Dortez","year":"2023","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2025.129346_bib30","doi-asserted-by":"crossref","first-page":"7463","DOI":"10.1007\/s00216-021-03706-9","article-title":"New microfluidic paper-based analytical device for iron determination in urine samples","volume":"413","author":"Ferreira","year":"2021","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.microc.2023.108462","article-title":"Targeting iron speciation in wines: design of a microfluidic paper-based device for determination of iron (II) and iron (III)","volume":"188","author":"Mesquita","year":"2023","journal-title":"Microchem. J."},{"key":"10.1016\/j.talanta.2025.129346_bib32","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1007\/s00216-019-02385-x","article-title":"Smartphone coupled with paper-based chemical sensor for on-site determination of iron (III) in environmental and biological samples","volume":"412","author":"Shrivas","year":"2020","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib33","doi-asserted-by":"crossref","first-page":"2820","DOI":"10.1002\/elps.201500235","article-title":"Capillary electrophoresis method for speciation of iron (II) and iron (III) in pharmaceuticals by dual precapillary complexation","volume":"36","author":"Gotti","year":"2015","journal-title":"Electrophoresis"},{"key":"10.1016\/j.talanta.2025.129346_bib34","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.jpba.2013.08.005","article-title":"Structural characterization of iron oxide\/hydroxide nanoparticles in nine different parenteral drugs for the treatment of iron deficiency anaemia by electron diffraction (ED) and X-ray powder diffraction (XRPD)","volume":"86","author":"F\u00fctterer","year":"2013","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.talanta.2025.129346_bib35","doi-asserted-by":"crossref","DOI":"10.1016\/j.jinorgbio.2021.111460","article-title":"Complexation of ferrous ions by ferrozine, 2, 2\u2032-bipyridine and 1, 10-phenanthroline: implication for the quantification of iron in biological systems","volume":"220","author":"Smith","year":"2021","journal-title":"J. Inorg. Biochem."},{"key":"10.1016\/j.talanta.2025.129346_bib36","doi-asserted-by":"crossref","first-page":"2149","DOI":"10.1007\/s12221-018-7568-6","article-title":"Transparent polycaprolactam electrospun nanofibers doped with 1, 10-phenanthroline optical sensor for colorimetric determination of iron (II) and vitamin C","volume":"19","author":"Najarzadekan","year":"2018","journal-title":"Fibers Polym."},{"key":"10.1016\/j.talanta.2025.129346_bib37","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.ijsrc.2024.02.005","article-title":"Feasibility of digital image colorimetric methods for iron determination in river sediment","volume":"39","author":"Lovato","year":"2024","journal-title":"Int. J. Sediment Res."},{"key":"10.1016\/j.talanta.2025.129346_bib38","doi-asserted-by":"crossref","first-page":"563","DOI":"10.4314\/bcse.v38i3.2","article-title":"Wax screen-based fabrication of paper devices for the determination of iron in particulates of selected welding fumes in Addis Ababa, Ethiopia","volume":"38","author":"Wendimu","year":"2024","journal-title":"Bull. Chem. Soc. Ethiop."},{"key":"10.1016\/j.talanta.2025.129346_bib39","doi-asserted-by":"crossref","first-page":"743","DOI":"10.3390\/bios13070743","article-title":"Application of paper-based microfluidic analytical devices (\u03bcPAD) in forensic and clinical toxicology: a review","volume":"13","author":"Musile","year":"2023","journal-title":"Biosensors"},{"key":"10.1016\/j.talanta.2025.129346_bib41","series-title":"ICH Guideline Q2(R2)","year":"2022"},{"key":"10.1016\/j.talanta.2025.129346_bib42","doi-asserted-by":"crossref","first-page":"5820","DOI":"10.1021\/acs.analchem.3c00378","article-title":"Capillary flow-driven microfluidics combined with a paper device for fast user-friendly detection of heavy metals in water","volume":"95","author":"Aryal","year":"2023","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2025.129346_bib43","doi-asserted-by":"crossref","first-page":"31","DOI":"10.2116\/analsci.32.31","article-title":"Determination of iron ion in the water of a natural hot spring using microfluidic paper-based analytical devices","volume":"32","author":"Ogawa","year":"2016","journal-title":"Anal. Sci."},{"key":"10.1016\/j.talanta.2025.129346_bib44","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.aca.2015.04.014","article-title":"Development of paper-based microfluidic analytical device for iron assay using photomask printed with 3D printer for fabrication of hydrophilic and hydrophobic zones on paper by photolithography","volume":"883","author":"Asano","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.talanta.2025.129346_bib45","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.jpha.2012.05.003","article-title":"An analytical method for Fe(II) and Fe(III) determination in pharmaceutical grade iron sucrose complex and sodium ferric gluconate complex","volume":"2","author":"Merli","year":"2012","journal-title":"J. Pharm. Anal."}],"container-title":["Talanta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039914025018375?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039914025018375?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T18:15:45Z","timestamp":1773944145000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0039914025018375"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":43,"alternative-id":["S0039914025018375"],"URL":"https:\/\/doi.org\/10.1016\/j.talanta.2025.129346","relation":{},"ISSN":["0039-9140"],"issn-type":[{"value":"0039-9140","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Analytical quality by design in the development of a paper-based microfluidic device for iron (II) determination as an impurity in iron (III) pharmaceuticals","name":"articletitle","label":"Article Title"},{"value":"Talanta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.talanta.2025.129346","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"129346"}}